One hundred fecal specimens obtained from patients with acute gastroenteritis were tested for rotavirus with nine commercial immunoassays to evaluate the sensitivity, specificity, predictive value, and diagnostic accuracy of these assays. Kits evaluated included two monoclonal antibody-based enzyme immunoassays (EIAs) (Rotaclone and Pathfinder Rotavirus), three polyclonal antibody-based EIAs (Rotavirus Immunoassay, Rotazyme II, and Wellcozyme Rotavirus), and four latex agglutination assays (Rotastat, Virogen Rotatest, Meritec-Rotavirus, and The Wellcome Latex Test). Thirty-eight of the 100 specimens were found to contain rotavirus by a reference microplate EIA. The accuracy of the reference assay was determined by RNA electrophoresis and a blocking assay on discordant specimens. The two monoclonal antibody EIAs had superior sensitivities (100%) and identified two positive specimens which were negative by the reference method but positive by the blocking assay. Among the polyclonal EIAs, all had sensitivities of greater than 90%, but specificities were variable; Rotazyme II, with a specificity of 50%, showed considerable discrepancy from other polyclonal EIAs. The latex tests had sensitivities ranging from 70 to 90% and specificities of 80 to 100%. Latex agglutination tests were more rapid than EIAs and did not require expensive equipment. The final choice of assay system will depend on the cost, speed, and accuracy requirements of the clinical laboratory.
Two previously demonstrated sensitive and specific enzyme immunoassays (EIAs) for rotavirus, one using polyclonal and monoclonal antisera (TestPack Rotavirus [TPK]; Abbott Laboratories) and the other using only monoclonal anti-rotavirus antibodies (Rotaclone [RTC]; Cambridge BioScience Corporation), were evaluated as potential reference assays for rotavirus testing in comparison with direct negative-staining electron microscopy (EM), the current laboratory standard. Two hundred and seven stool samples collected consecutively during the winter of 1989 from children with acute diarrhea admitted to a ward for infants from 0 to 2 years of age were tested by the EIAs and by EM. TPK specimens were read visually; RTC results were read spectrophotometrically. Specimens with discordant EIA and EM results were further evaluated by a fluorescent focus assay. Specimens positive by EM and those negative by EM but positive by fluorescent focus assay were considered to be positive for rotavirus. Of the 207 stools tested, 35 (17%) were positive for rotavirus by these criteria. EM had a sensitivity of only 80%. Specificities were 100% for RTC and EM and 89% for TPK. These findings indicate that EM, although very specific, is relatively insensitive compared with a highly sensitive monoclonal antibody-based EIA. An EIA with high sensitivity and specificity, such as RTC, is a more appropriate reference standard for rotavirus testing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.