This study has reaffirmed the feasibility and safety of stent graft repair in treating stable patients with selected penetrating subclavian artery injuries. The results of this study also confirmed acceptable long-term follow-up without any limb or life threatening complications. We conclude that endovascular repair should be considered the first choice of treatment in stable patients with subclavian artery injuries.
The presence of hypovolemic shock, internal carotid artery injury, complete vessel transection, and arterial ligation are associated with unfavorable outcome. Penetrating injury to the brachiocephalic, common carotid, or internal carotid artery should be repaired rather than ligated when technically possible. Subsequent ischemic or hemorrhagic cerebral infarction is unpredictable, but overall outcome is superior to that with ligation of the injured artery.
The purpose of this study was to analyse the intermediate-term results of an arthroscopic procedure to debride and resurface the arthritic glenoid, in a middle-aged population, using an acellular human dermal scaffold. Between 2003 and 2005, thirty-two consecutive patients underwent an arthroscopic debridement and biological glenoid resurfacing for glenohumeral arthritis. The diagnoses included primary osteoarthrosis (28 patients), arthritis after arthroscopic reconstruction for anterior instability (1 patient) and inflammatory arthritis (3 patients). All shoulders were assessed clinically using the Constant and Murley score, and results graded according to Neer's criteria. Statistical analysis was performed to determine significant parameters and associations. A significant improvement (P < 0.0001) in each parameter of the subjective evaluation component (severity of pain, limitation in daily living and recreational activities) of the Constant score was observed. The Constant and Murley score increased significantly (P < 0.0001) from a median of 40 points (range 26-63) pre-operatively to 64.5 (range 19-84) at the final assessment. Overall, the procedure was considered as "successful outcome" in 23 patients (72%) and as a "failure" in 9 patients (28%). According to Neer's criteria, the result was categorized as excellent in 9 (28%), satisfactory in 14 (44%) and unsatisfactory in 9 (28%). Within the unsatisfactory group, there were five conversions to prosthetic arthroplasty. A standard magnetic resonance imaging was performed on 22 patients in the successful outcome group; glenoid cartilage was identified in 12 (thick in 5, intermediate in 1, thin in 6) and could not be identified in 10 patients (complete/incomplete loss in 5, technical difficulties in 5). Overall, five complications included transient axillary nerve paresis, foreign-body reaction to biological material, inter-layer dissociation, mild chronic non-specific synovitis and post-traumatic contusion. Dominance of affected extremity and generalized disease (diabetes, rheumatoid arthritis, generalized osteoarthritis) was associated with an unsatisfactory outcome (P < 0.05). Arthroscopic debridement and biological resurfacing of the glenoid is a minimally invasive therapeutic option for pain relief, functional improvement and patient satisfaction, in glenohumeral osteoarthritis, in the intermediate-term.
The coracoid process forms an important part of scapular-glenoid construct and is involved in many surgical procedures on the glenohumeral joint. The unique three-dimensional orientation of each coracoid pillar makes radiographic imaging difficult. Congenital variations and minimal traumatic/iatrogenic changes in this orientation can predispose to subcoracoid impingement. We performed a quantitative and statistical analysis of the osseous anatomy of the coracoid process in 101 scapulae; the purpose was to determine the anatomical variations and gender-specific differences in the length, breadth, thickness, vertical and horizontal projections, and triplane angulations of each individual coracoid pillar. All parameters were measured in reference to the glenoid plane to ensure surgical and radiological applicability. The mean dimensions of the inferior coracoid pillar were 31.1 x 16.6 x 9.9 mm and that of the superior coracoid pillar were 41.7 x 14.2 x 8.4 mm (medial)/6.6 mm (lateral). The mean maximal harvestable coracoid length measured 19.0 mm. The mean angular orientation of the inferior coracoid pillar, with reference to the glenoid, measured 51.2 degrees (axial), 126.1 degrees (sagittal), and 134.6 degrees (coronal), and that of the superior coracoid pillar measured 146.1 degrees (axial) with an interpillar angulation of 84.9 degrees (axial). A statistically significant gender difference (P < 0.05) was found in the lengths, breadths, and projections of each coracoid pillar. We used data from this study to devise two new radiographic views (for imaging individual coracoid pillars), to calculate dimensions and orientation of internal fixation/prosthetic hardware during surgery, and conceptualize a geometric model to explain the role of measured parameters in coracoid impingement syndrome.
Innominate artery injuries have high rates of morbidity and mortality. A vascular surgical approach with pre-operative angiography, when possible and careful surgical planning by a dedicated team promotes better surgical results. Endovascular and hybrid procedures can become the method of choice when treating stable patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.