Currently, ALS clinical trials require large sample size and the participation of many clinical evaluators to perform the outcome measure. High variability due to testers, instruments, or patients performance errors may result in systematic bias or random error leading to erroneous or uninterpretable results. Consequently, a quality control system that aims to produce high quality data in terms of reproducibility and accuracy to ensure reliability of the primary outcome measure is essential. In this paper we report our experience in preparing and executing a prospective quality control system that was implemented in conjunction with a large multicenter, multinational randomized placebo-controlled phase III clinical trial in ALS. We have shown that a prospective quality control system is highly effective to ensure inter- and intra-rater reliability of vital capacity as a primary outcome measure during the entire trial.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.