This work is related to reliability of strain measurement in flexible printed circuit boards (fPCBs) made with polyimide substrate. It was observed that the fPCBs are very sensitive to strain mounting stiffness. The indirect measurement method will be done employing High Speed Camera (HSP). The direct method will be formulated in two ways: 1) conventional strain gauge glued in an fPCBs; 2) printed strain gauge in a polyimide substrate. This paper will point out mistakes and show advantages when using different method to extract the deformation field of the selected area in a flexible thin film.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.