We present the case of a 14-year-old female patient with recurrent episodes of paroxysmal supraventricular tachycardia (PSVT). Her ECG showed a PR interval of 160 ms in lead II, and a delta wave pattern in leads V2 and V3, with a normal QRS interval of 100 ms. We analyzed the three criteria for confirmation of minimal pre-excitation: (i) absence of a Q wave in V6; (ii) presence of an R wave in V1 and (iii) absence of an R wave in avR. The 3 criteria were not met and failed to establish a diagnosis of ventricular pre-excitation. The electrophysiological study confirmed the presence of a left accessory pathway. A new criterion was analyzed: the variation of the PR interval on the same ECG. A difference of >30 ms was successful to confirm the presence of an accessory pathway before ablation and its absence after catheter ablation.
Purpose TMAO, a gut microbiota derived byproduct, has been associated with various cardiometabolic diseases by promoting oxidative stress and inflammation. The liver is the main organ for TMAO production and chronic exposure to high doses of TMAO could alter its function. In the present study we evaluated the effect of chronic exposure of high TMAO doses on liver oxidative stress, inflammation and fibrosis. Methods TMAO was administered daily via gastric gavage to 24 male Wistar rats for 3 months. The animals were divided in three groups, a high-dosage group that received 40 mg of TMAO/day, a low-dose group that received 20 mg of TMAO/day and a control group treated with vehicle. Blood was drawn for the quantification of TMAO and liver tissues were harvested for the assessment of oxidative stress (MDA, GSH, GSSG, GPx, CAT, and 8-oxo-dG) and inflammation by quantification of NOS and COX-2 expression. The evaluation of fibrosis was made by western blot analysis of α-SMA and Collagen-3 protein expression. Moreover, histological investigation and immunohistochemical staining of iNOS were performed in order to assess the liver damage. Results After 3 months of TMAO exposure, TMAO serum levels enhanced in parallel with significant increases in MDA and GSSG levels in liver and lower values of GSH and GSH/GSSG ratio as well as significant decrease in GPx and CAT activities. Inflammation was also highlighted, with a significant increase in iNOS and COX-2 expression, but without structural changes and without induction of liver fibrosis. Conclusion Chronic administration of TMAO for 3 months induced liver oxidative stress and inflammation without the appearance of fibrosis or liver structural changes.
INTRODUCTION Catheter ablation is the treatment of choice for patients with recurrent paroxysmal atrial fibrillation (AF) in which antiarrhythmic drug therapy has failed to maintain sinus rhythm. Since its first introduction, intracardiac echocardiography (ICE) has proved to increase the efficacy and reduce complications in AF catheter ablation. One of the main advantages of ICE in the electrophysiology laboratory is the reduction of radiation exposure, for both the patient and the physician. Multiple recent studies have shown the feasibility and safety of zero or near-zero fluoroscopy AF ablation, including transseptal puncture, and outlined the importance of using ICE under the support of 3D mapping systems in reducing radiation exposure. PURPOSE The aim of this study was to show whether the use of ICE reduced the radiation exposure and total procedure time in recurrent paroxysmal AF patients undergoing radiofrequency catheter ablation. METHODS Forty patients that undergone radiofrequency catheter ablation for recurrent paroxysmal AF between January 2018 and May 2019 were included. They were divided in two groups: Group 1 – 20 patients in which ICE was performed and Group 2 – 20 patients in which ablation was performed without ICE guidance. We compared the total ablation time and fluoroscopy dose and time between the two groups. The total ablation time was defined as the time from the groin puncture until the withdrawal of all catheters. RESULTS Among the 40 patients included, 28 were men (70%) and the mean age was 57 years old. The mean procedure time was similar between the two groups (175 ± 52.0 for group 1 and 193 ± 49.9 for group 2, p = 0.33). The difference between the two groups was observed in fluoroscopy dose (9914.13 ± 5018.14 vs. 14561.43 ± 7446.1, p = 0.02) and time (26.04 ± 12.5 vs. 40.52 ± 12.6, p = 0.001). We found that in both groups higher fluoroscopy dose was correlated with higher fluoroscopy time (R = 0.74, p = 0.0001 vs. R = 0.57, p = 0.008) and higher total procedure time (R = 0.63, p = 0.002 vs. R = 0.46, p = 0.03). Furthermore, there was also a correlation between higher fluoroscopy dose and time (R = 0.59, p = 0.005 vs. R = 0.58, p = 0.006). No severe procedure-related complications were recorded. CONCLUSIONS This study shows that the use of ICE for recurrent paroxysmal AF catheter ablation reduces radiation exposure by lowering the fluoroscopy dose and the time of exposure. As a result, by increasing the training and learning curve in low-experienced centers it may finally get us closer to the ideal zero or near-zero fluoroscopy ablation. Abstract P338 Figure. ICE-guided transseptal puncture
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.