Vitamin D, a crucial hormone in the homeostasis and metabolism of calcium bone, has lately been found to produce effects on other physiological and pathological processes genomically and non-genomically, including the cardiovascular system. While lower baseline vitamin D levels have been correlated with atherogenic blood lipid profiles, 25(OH)D supplementation influences the levels of serum lipids in that it lowers the levels of total cholesterol, triglycerides, and LDL-cholesterol and increases the levels of HDL-cholesterol, all of which are known risk factors for cardiovascular disease. Vitamin D is also involved in the development of atherosclerosis at the site of the blood vessels. Deficiency of this vitamin has been found to increase adhesion molecules or endothelial activation and, at the same time, supplementation is linked to the lowering presence of adhesion surrogates. Vitamin D can also influence the vascular tone by increasing endothelial nitric oxide production, as seen in supplementation studies. Deficiency can lead, at the same time, to oxidative stress and an increase in inflammation as well as the expression of particular immune cells that play a pivotal role in the development of atherosclerosis in the intima of the blood vessels, i.e., monocytes and macrophages. Vitamin D is also involved in atherogenesis through inhibition of vascular smooth muscle cell proliferation. Furthermore, vitamin D deficiency is consistently associated with cardiovascular events, such as myocardial infarction, STEMI, NSTEMI, unstable angina, ischemic stroke, cardiovascular death, and increased mortality after acute stroke. Conversely, vitamin D supplementation does not seem to produce beneficial effects in cohorts with intermediate baseline vitamin D levels.
Introduction: During the last three decades, there has been an excess weight epidemic due to changes in nutrition and lifestyle. Few data on the prevalence of overweight and obesity in children in Romania were published, without a single study representative at the national level. There are reports on the higher level of overweight and obesity in urban areas compared to rural ones. This study aimed to estimate the prevalence of underweight, overweight, obesity and severe obesity in children enrolled in schools from the urban area. Material and methods: For this cross-sectional study, children from 177 schools from the urban area of five counties from the northwestern part of Romania were included after the parents signed written informed consent. Anthropometric data were recorded (weight, height) based on World Health Organization (WHO) recommendations and Body-Mass-Index (BMI), and the z-score for BMI were calculated. The nutritional status was estimated using three reference criteria: WHO, International Obesity Task Force (IOTC) and the Center for Disease Control and Prevention (CDC). Results: We analyzed data of 21,650 children (48.19% boys) age between 7 and 18 years. The prevalence of overweight was 13.8%, 16.2% and 20.3%, of obesity was 10.7%, 10.0% and 5.7% and of severe obesity was 5.1%, 1.2% and 1.6% (using WHO, CDC and IOTF cut-offs). Underweight was present in 5.2% (WHO), 6% (CDC) and 2.6% (IOTF). The highest prevalence of overweight (including obesity) was found in children aged 10 years, and the lowest in adolescents at 18 years. Boys have a higher prevalence of excess weight than girls. Using IOTF cut-offs, the prevalence of obesity and severe obesity was lower than using WHO criteria. Conclusions: The prevalence of overweight (including obesity) in children from the urban area of Western Romania was recorded at alarming levels, higher in boys and at the pre-puberty ages. There are significant differences based on the reference system used. It is important to correctly choose the reference for the definition of overweight and obesity to have the correct estimation of the target for public health measures.
Background and Objectives: Prior studies have identified a number of predictors for Atrial fibrillation (AF) ablation success, including comorbidities, the type of AF, and left atrial (LA) size. Ectopic foci in the initiation of paroxysmal AF are frequently found in pulmonary veins. Our aim was to assess how pulmonary vein anatomy influences the recurrence of atrial fibrillation after radiofrequency catheter ablation. Materials and Methods: Eighty patients diagnosed with paroxysmal or persistent AF underwent radiofrequency catheter ablation (RFCA) between November 2016 and December 2017. All of these patients underwent computed tomography before AF ablation. PV anatomy was classified according to the presence of common PVs or accessory PVs. Several clinical and imagistic parameters were recorded. After hospital discharge, all patients were scheduled for check-up in an outpatient clinic at 3, 6, 9, and 12 months after RFCA to detect AF recurrence. Results: A total of 80 consecutive patients, aged 53.8 ± 9.6 years, 54 (67.5%) men and 26 (32.5%) women were enrolled. The majority of patients had paroxysmal AF 53 (66.3%). Regular PV anatomy (2 left PVs, 2 right PVs) was identified in 59 patients (73.7%), a left common trunk (LCT) was detected in 15 patients (18.7%), an accessory right middle pulmonary vein (RMPV) was found in 5 patients (6.25%) and one patient presented both an LCT and an RMPV. The median follow-up duration was 14 (12; 15) months. Sinus rhythm was maintained in 50 (62.5%) patients. Age, gender, antiarrhythmic drugs, and the presence of cardiac comorbidities were not predictive of AF recurrence. The diagnosis of persistent AF before RFCA was more closely associated with an increase in recurrent AF after RFCA than after paroxysmal AF (p = 0.01). Longer procedure times (>265 min) were associated with AF recurrence (p = 0.04). Patients with an LA volume index of over 48.5 (mL/m2) were more likely to present AF recurrence (p = 0.006). Multivariate analysis of recurrence risk showed that only the larger LA volume index and variant PV anatomy were independently associated with AF recurrence. Conclusion: The study demonstrated that an increased volume of the left atrium was the most important predictive factor for the risk of AF recurrence after catheter ablation. Variant anatomy of PV was the only other independent predictive factor associated with a higher rate of AF recurrence.
Atherosclerosis is a key pathological process that causes a plethora of pathologies, including coronary artery disease, peripheral artery disease, and ischemic stroke. The silent progression of the atherosclerotic disease prompts for new surveillance tools that can visualize, characterize, and provide a risk evaluation of the atherosclerotic plaque. Conventional ultrasound methods—bright (B)-mode US plus Doppler mode—provide a rapid, cost-efficient way to visualize an established plaque and give a rapid risk stratification of the patient through the Gray–Weale standardization—echolucent plaques with ≥ 50% stenosis have a significantly greater risk of ipsilateral stroke. Although rather disputed, the measurement of carotid intima-media thickness (C-IMT) may prove useful in identifying subclinical atherosclerosis. In addition, contrast-enhanced ultrasonography (CEUS) allows for a better image resolution and the visualization and quantification of plaque neovascularization, which has been correlated with future cardiovascular events. Newly emerging elastography techniques such as strain elastography and shear-wave elastography add a new dimension to this evaluation—the biomechanics of the arterial wall, which is altered in atherosclerosis. The invasive counterpart, intravascular ultrasound (IVUS), enables an individualized assessment of the anti-atherosclerotic therapies, as well as a direct risk assessment of these lesions through virtual histology IVUS.
Aims: Intracardiac echocardiography (ICE) is a relatively young technique used during complex electrophysiology proce-dures, such as atrial fibrillation (AF) ablation. The aim of this study was to assess whether the use of ICE modifies the radia-tion exposure at the beginning of the learning curve in AF ablation. Materials and methods: In this retrospective study, 52 patients, in which catheter ablation for paroxysmal or persistent AF was performed, were included. For 26 patients we used ICE guidance together with fluoroscopy, whereas for the remaining 26 patients we used fluoroscopy alone, all supported by electroanatomical mapping. We compared total procedure time and radiation exposure, including fluoroscopy dose and time between the two groups and along the learning curve. Results: Most of the patients included were suffering from paroxysmal AF (40, 76%), pulmonary vein isolation being performed in all patients, without secondary ablation sites. The use of ICE was associated with a lower fluoroscopy dose (11839.60±6100.6 vs. 16260.43±8264.5 mGy, p=0.041) and time (28.00±12.5 vs. 42.93±12.7 minutes, p=0.001), whereas the mean procedure time was similar between the two groups (181.54±50.3 vs 197.31±49.8 minutes, p=0.348). Radiation exposure was lower in the last 9 months compared to the first 9 months of the study (p<0.01), decreasing gradually along the learning curve. Conclusions: The use of ICE lowers radiation exposure in AF catheter ablation from the beginning of the learning curve, without any difference in terms of acute safety or efficacy. Aware-ness towards closest to zero radiation exposure during electrophysiology procedures should increase in order to achieve better protection for both patient and medical staff.
Atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA) remains a challenging issue. This study aims to explore the left atrial appendage function by transesophageal echocardiography (TEE) and assess its value in predicting AF recurrence following RFCA in paroxysmal AF patients. Eighty-one patients with paroxysmal AF that underwent RFCA were recruited. TEE was performed before ablation with the assessment of left atrial appendage emptying flow velocity (LAAeV). AF recurrence occurred in 24 patients (29.6%) within 12 months after RFCA. The left atrium diameter (LAD) and left atrium volume index (LAVI) were both significantly higher in the recurrence group compared to the non-recurrence group, while the LAAeV was significantly lower in the recurrence group. LAD, LAVi and LAAeV were univariately significant risk factors for AF recurrence after ablation. Based on receiver operating curve (ROC), LAAeV < 40.5 cm/s, LAVi > 40.5 mL and LAD > 41 mm were identified as cut-off values for predicting AF recurrence. In multivariate regression analysis LAAeV < 40.5 cm/s (HR 8.194, 95% CI 2.980–22.530, p < 0.001) was identified as the only statistically significant independent predictor of AF recurrence, as the statistical significance threshold was not achieved for LAVI > 40.5 mL and LAD > 41 mm (p = 0.319; p = 0.507, respectively). A low LAAeV was the only important independent predictor of AF recurrence within 1 year after first RFCA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.