SUMMARY The potential of various quantitative lateral flow (LF) based assays utilizing up-converting phosphor (UCP) reporters for the diagnosis of schistosomiasis is reviewed including recent developments. Active infections are demonstrated by screening for the presence of regurgitated worm antigens (genus specific polysaccharides), whereas anti-Schistosoma antibodies may indicate ongoing as well as past infections. The circulating anodic antigen (CAA) in serum or urine (and potentially also saliva) is identified as the marker that may allow detection of single-worm infections. Quantitation of antigen levels is a reliable method to study effects of drug administration, worm burden and anti-fecundity mechanisms. Moreover, the ratio of CAA and circulating cathodic antigen (CCA) is postulated to facilitate identification of either Schistosoma mansoni or Schistosoma haematobium infections. The UCP-LF assays allow simultaneous detection of multiple targets on a single strip, a valuable feature for antibody detection assays. Although antibody detection in endemic regions is not a useful tool to diagnose active infections, it gains potential when the ratio of different classes of antibody specific for the parasite/disease can be determined. The UCP-LF antibody assay format allows this type of multiplexing, including testing a linear array of up to 20 different targets. Multiple test spots would allow detection of specific antibodies, e.g. against different Schistosoma species or other pathogens as soil-transmitted helminths. Concluding, the different UCP-LF based assays for diagnosis of schistosomiasis provide a collection of tests with relatively low complexity and high sensitivity, covering the full range of diagnostics needed in control programmes for mapping, screening and monitoring.
In the detection of parasitic infection, the traditional methods based on microscopy often have low sensitivity and/or specificity compared with the newer, molecular tests. An assay based on real-time PCR and a reagent strip test for detecting circulating cathodic antigen (CCA) have both now been compared with urine filtration and microscopy, in the detection of Schistosoma haematobium infections. Urine samples, obtained from 74 'cases' in areas of Ghana with endemic S. haematobium and 79 'controls' from non-endemic areas, were each checked using the three methods. With the results of the filtration and microscopy taken as the 'gold standard', real-time PCR was found to be 100% specific and 89% sensitive whereas the CCA strips were 91% specific and 41% sensitive. With the samples found to contain > or =50 eggs/10 ml (indicating relatively intense infections), the sensitivities of the PCR and CCA were higher, at 100% and 62%, respectively. As expected, egg counts were negatively correlated with the number of amplification cycles needed, in the PCR, to give a signal that exceeded the background (r=-0.38; P<0.01). Although the real-time PCR and CCA strip tests are very different, both show promise in the detection of S. haematobium infections. The PCR has optimal specificity and high sensitivity but the specificity of the CCA strips and the sensitivity of both tools could still be improved. A more thorough re-evaluation of the sensitivity and specificity of microscopy and these newer diagnostic methods, with an estimation of the cost-effectiveness of each technique, is recommended.
BackgroundElimination of schistosomiasis as a public health problem and interruption of transmission in selected areas are key goals of the World Health Organization for 2025. Conventional parasitological methods are insensitive for the detection of light-intensity infections. Techniques with high sensitivity and specificity are required for an accurate diagnosis in low-transmission settings and verification of elimination. We determined the accuracy of a urine-based up-converting phosphor-lateral flow circulating anodic antigen (UCP-LF CAA) assay for Schistosoma haematobium diagnosis in low-prevalence settings in Zanzibar, Tanzania.MethodologyA total of 1,740 urine samples were collected in 2013 from children on Pemba Island, from schools where the S. haematobium prevalence was <2%, 2–5%, and 5–10%, based on a single urine filtration. On the day of collection, all samples were tested for microhematuria with reagent strips and for the presence of S. haematobium eggs with microscopy. Eight months later, 1.5 ml of urine from each of 1,200 samples stored at -20°C were analyzed by UCP-LF CAA assay, while urine filtration slides were subjected to quality control (QCUF). In the absence of a true ‘gold’ standard, the diagnostic performance was calculated using latent class analyses (LCA).Principal FindingsThe ‘empirical’ S. haematobium prevalence revealed by UCP-LF CAA, QCUF, and reagent strips was 14%, 5%, and 4%, respectively. LCA revealed a sensitivity of the UCP-LF CAA, QCUF, and reagent strips of 97% (95% confidence interval (CI): 91–100%), 86% (95% CI: 72–99%), and 67% (95% CI: 52–81%), respectively. Test specificities were consistently above 90%.Conclusions/SignificanceThe UCP-LF CAA assay shows high sensitivity for the diagnosis of S. haematobium in low-endemicity settings. Empirically, it detects a considerably higher number of infections than microscopy. Hence, the UCP-LF CAA employed in combination with QCUF, is a promising tool for monitoring and surveillance of urogenital schistosomiasis in low-transmission settings targeted for elimination.
An earlier reported laboratory assay, performed in The Netherlands, to diagnose Schistosoma infections by detection of the parasite antigen CAA in serum was converted to a more user-friendly format with dry reagents. The improved assay requires less equipment and allows storage and worldwide shipping at ambient temperature. Evaluation of the new assay format was carried out by local staff at Ampath Laboratories, South Africa. The lateral flow (LF) based assay utilized fluorescent ultrasensitive up-converting phosphor (UCP) reporter particles, to be read by a portable reader (UPlink) that was also provided to the laboratory. Over a period of 18 months, about 2000 clinical samples were analyzed prospectively in parallel with a routinely carried out CAA-ELISA. LF test results and ELISA data correlated very well at CAA concentrations above 300 pg/mL serum. At lower concentrations the UCP-LF test indicates a better performance than the ELISA. The UCP-LF strips can be stored as a permanent record as the UCP label does not fade. At the end of the 18 months testing period, LF strips were shipped back to The Netherlands where scan results obtained in South Africa were validated with different UCP scanning equipment including a novel, custom developed, small lightweight UCP strip reader (UCP-Quant), well suited for testing in low resource settings. Conclusion The dry format UCP-LF assay was shown to provide a robust and easy to use format for rapid testing of CAA antigen in serum. It performed at least as good as the ELISA with respect to sensitivity and specificity, and was found to be superior with respect to speed and simplicity of use. Worldwide shipping at ambient temperature of the assay reagents, and the availability of small scanners to analyze the CAA UCP-LF strip, are two major steps towards point-of-care (POC) applications in remote and resource poor environments to accurately identify low (30 pg CAA/mL serum; equivalent to about 10 worm pairs) to heavy Schistosoma infections.
BackgroundSchistosomiasis affects 218 million people worldwide, with most infections in Africa. Prevalence studies suggest that people with chronic schistosomiasis may have higher risk of HIV-1 acquisition and impaired ability to control HIV-1 replication once infected. We hypothesized that: (1) pre-existing schistosome infection may increase the odds of HIV-1 acquisition and that the effects may differ between men and women, and (2) individuals with active schistosome infection at the time of HIV-1 acquisition may have impaired immune control of HIV-1, resulting in higher HIV-1 viral loads at HIV-1 seroconversion.Methodology/Principal findingsWe conducted a nested case-control study within a large population-based survey of HIV-1 transmission in Tanzania. A population of adults from seven villages was tested for HIV in 2007, 2010, and 2013 and dried blood spots were archived for future studies with participants’ consent. Approximately 40% of this population has Schistosoma mansoni infection, and 2% has S. haematobium. We tested for schistosome antigens in the pre- and post-HIV-1-seroconversion blood spots of people who acquired HIV-1. We also tested blood spots of matched controls who did not acquire HIV-1 and calculated the odds that a person with schistosomiasis would become HIV-1-infected compared to these matched controls. Analysis was stratified by gender. We compared 73 HIV-1 seroconverters with 265 controls. Women with schistosome infections had a higher odds of HIV-1 acquisition than those without (adjusted OR = 2.8 [1.2–6.6], p = 0.019). Schistosome-infected men did not have an increased odds of HIV-1 acquisition (adjusted OR = 0.7 [0.3–1.8], p = 0.42). We additionally compared HIV-1 RNA levels in the post-seroconversion blood spots in HIV-1 seroconverters with schistosomiasis versus those without who became HIV-infected in 2010, before antiretroviral therapy was widely available in the region. The median whole blood HIV-1 RNA level in the 15 HIV-1 seroconverters with schistosome infection was significantly higher than in the 22 without schistosomiasis: 4.4 [3.9–4.6] log10 copies/mL versus 3.7 [3.2–4.3], p = 0.017.Conclusions/SignificanceWe confirm, in an area with endemic S. mansoni, that pre-existing schistosome infection increases odds of HIV-1 acquisition in women and raises HIV-1 viral load at the time of HIV-1 seroconversion. This is the first study to demonstrate the effect of schistosome infection on HIV-1 susceptibility and viral control, and to differentiate effects by gender. Validation studies will be needed at additional sites.
Abstract. Animal and human studies suggest that Schistosoma mansoni infection may increase risk of human immunodeficiency virus (HIV) acquisition. Therefore, we tested 345 reproductive age women in rural Tanzanian villages near Lake Victoria, where S. mansoni is hyperendemic, for sexually transmitted infections (STIs) and schistosomiasis by circulating anodic antigen (CAA) serum assay. Over one-half (54%) had an active schistosome infection; 6% were HIVseropositive. By univariate analysis, only schistosome infection predicted HIV infection (odds ratio [OR] = 3.9, 95% confidence interval = [1.3-12.0], P = 0.015) and remained significant using multivariate analysis to control for age, STIs, and distance from the lake (OR = 6.2 [1.7-22.9], P = 0.006). HIV prevalence was higher among women with more intense schistosome infections (P = 0.005), and the median schistosome intensity was higher in HIV-infected than -uninfected women (400 versus 15 pg CAA/mL, P = 0.01). This finding suggests that S. mansoni infection may be a modifiable HIV risk factor that places millions of people worldwide at increased risk of HIV acquisition.
BackgroundAccurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction.MethodsCentrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test.ResultsImplementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay.ConclusionsLarger sample input increased Sn of the UCAA assay to a level indicating ‘true’ infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.