In practice, similar findings found on FECG should raise the index of suspicion for the presence of congenital heart disease and prompt a targeted ultrasound scan.
Objectives: This descriptive study was performed to evaluate the capability of a non-invasive transabdominal electrocardiographic system to extract clear fetal electrocardiographic (FECG) measurements from intrauterine growth restricted (IUGR) fetuses and to assess whether abdominal FECG parameters can be developed as markers for evaluating the fetal cardiac status in IUGR.Methods: Transabdominal FECG was attempted in 20 controls and 15 IUGR singleton pregnancies at 20+0−33+6 weeks gestation. Standard ECG parameters were compared between the study groups and evaluated for their correlation. Accuracy for the prediction of IUGR by cut off values of the different FECG parameters was also determined.Results: Clear P-QRST complexes were recognized in all cases. In the IUGR fetuses, the QT and QTc intervals were significantly prolonged (p = 0.017 and p = 0.002, respectively). There was no correlation between ECG parameters and Doppler or other indices to predict IUGR. The generation of cut off values for detecting IUGR showed increasing sensitivities but decreasing specificities with the prolongation of ECG parameters.Conclusion: The study of fetal electrocardiophysiology is now feasible through a non-invasive transabdominal route. This study confirms the potential of FECG as a clinical screening tool to aid diagnosis and management of fetuses after key limitations are addressed. In the case of IUGR, both QT and QTc intervals were significantly prolonged and thus validate earlier study findings where both these parameters were found to be markers of diastolic dysfunction. This research is a useful prelude to a test of accuracy and Receiver Operating Characteristics (ROC) study.
Problem: Recent studies show that lower genital tract infection with genital mycoplasma may be associated with the pathology of female infertility. However, this association remains controversial due to the variable prevalence, sample sizes, and different methods used to diagnose genital mycoplasma infection. The aim of the present meta-analysis was to gain better understanding of the specific impact of genital mycoplasma on female infertility.
Method of Study:A systematic review of literature on the association of genital mycoplasma (Mycoplasma genitalium, Mycoplasma hominis, Ureaplasma parvum, and Ureaplasma urealyticum) infection and female infertility was performed using three electronic databases: PubMed, Scopus, and CINAHL, from January 2000 to January 2020. Pooled odds ratio (OR) and 95% confidence intervals for genital mycoplasma infection and female infertility were derived from a fixed effects model.
Results:This meta-analysis included eight studies conducted in six countries. Based on the results, women with infertility had a statistically higher odds of having any genital mycoplasma infection (p < .0001) compared to the control group. The pooled OR of all the included studies was 3.82 (95% CI: 2.55, 5.72). There was an unremarkable heterogeneity in all the studies included in this meta-analysis (I 2 = 0%, p = .48). A subgroup analysis also showed that M. genitalium, M. hominis, and U. urealyticum infections are significantly associated with female infertility.
Conclusion:Our meta-analysis showed a significant association between M. genitalium, M. hominis, and U. urealyticum infections and female infertility. This evidence supports the development of guidelines for the diagnosis and treatment of genital mycoplasma infections to prevent female infertility.
Abstract:Since the first observations of Cremer in 1906, fetal electrocardiogram (ECG) measurements via the maternal abdominal wall have remained a formidable challenge for clinical technicians and engineers in the cutting-edge field of information theory.Previous obstacles in extracting fetal ECG still complicate their acquisition at the present. These include three main difficulties for non-invasive measurement of fetal ECG: first, the low signal to noise ratio; second, the lack of a standard lead system for fetal ECG on the maternal abdomen; and third, the factor of fetal movement or non-stationarity during recording. A new extraction system based on blind source separation with reference signals (BSSR) was utilized and our detection rates, both off-line (91%) and on-line (60%), in pregnancies of 20 to 41 weeks of gestation have shown a marked improvement from earlier attempts. With this development, we discuss the potentials and limitations of this new system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.