HighlightsThe incidence of chondrosarcoma transformation averaged 4%, 75.2% occurring between ages 20–40 and 56.2% at the pelvis and proximal femur.In the general HME population, plain radiographs provided cost per life-year gain of £19,013 compared to £53,392 in MRIs. ICER in MRIs compared to X-rays was £80,128. However, for every generation of HME patients screened over 20 years, X-ray radiation induced 0.65 cancers.Psychological effects of false-positives were marginal.Screening only higher-risk groups (males or EXT1) reduced cost but benefited fewer patients.
Introduction: Volume assessment in end-stage kidney disease patients on hemodialysis (HD) remains inadequate by existing methods: clinical examination, bioimpedance spectroscopy, measurement of inferior vena cava diameter by ultrasound (IVCD), and plasma B-type natriuretic peptide (NT-pro BNP). This study aims to compare the performance of lung ultrasound against existing methods for volume assessment in a HD cohort. Methods: Two nephrologists independently performed 28-point lung ultrasound immediately before and after midweek HD in 50 patients. Lung congestion was classified into mild, moderate, and severe categories based on lung ultrasound findings. Clinical examination for crepitations and oedema, change in hydration status (ΔHS) measured by bioimpedance spectroscopy, NT-pro BNP, IVCD during inspiration (IVCDimin), expiration (IVCDimax), and inferior vena cava collapsibility index were also assessed before and after midweek HD. Findings: In all, 61% of patients with normohydration status by bioimpedance spectroscopy had moderate or severe lung congestion on lung ultrasound. There were significant correlations between predialysis lung ultrasound, and NT-pro BNP (r = 0.432, P = 0.004), ΔHS (r = 0.447, P < 0.001), and IVCD parameters (P < 0.05). Some correlations weakened postdialysis (ΔHS [r = 0.322, P = 0.01] and IVCDimax [r = 0.307, P = 0.03]), whereas NT-pro BNP and ΔHS paradoxically increased in 28% and 30% of the cohort, respectively. On receiver operator curve analysis, most methods of volume assessment had limited discriminatory power to detect mild lung congestion. Discussion: Lung ultrasound demonstrates some comparability with existing volume assessment methods in Asian dialysis patients. However, it appears more effective at detecting subclinical pulmonary congestion, and tracking fluid changes real-time compared to bioimpedance spectroscopy and NT-pro BNP.
Background
Chronic kidney disease (CKD) is associated with fluid retention, which increases total body water (TBW) and leads to changes in intracellular water (ICW) and extracellular water (ECW). This complicates accurate assessments of body composition. Analysis of bioelectrical impedance may improve the accuracy of evaluation in CKD patients and multiple machines and technologies are available. We compared body composition by bioimpedance spectroscopy (BIS) against multi-frequency bioimpedance analysis (BIA) in a multi-ethnic Asian population of stable, non-dialysis CKD patients.
Methods
We recruited 98 stable CKD patients comprising 54.1% men and 70.4% Chinese, 9.2% Malay, 13.3% Indian, and 8.2% other ethnicities. Stability was defined as no variation in serum creatinine > 20% over three months. Patients underwent BIS analyses using a Fresenius body composition monitor, while BIA analyses employed a Bodystat Quadscan 4000.
Results
Mean TBW values by BIS and BIA were 33.6 ± 7.2 L and 38.3 ± 7.4 L; mean ECW values were 15.8 ± 3.2 L and 16.9 ± 2.7 L; and mean ICW values were 17.9 ± 4.3 L and 21.0 ± 4.9 L, respectively. Mean differences for TBW were 4.6 ± 1.9 L (
P
< 0.001), for ECW they were 1.2 ± 0.5 L (
P
< 0.001), and for ICW they were 3.2 ±1.8 L (
P
< 0.001). BIA and BIS measurements were highly correlated: TBW r = 0.970, ECW r = 0.994, and ICW r = 0.926. Compared with BIA, BIS assessments of fluid overload appeared to be more associated with biochemical and clinical indicators.
Conclusion
Although both BIA and BIS can be used for body water assessment, clinicians should be aware of biases that exist between bioimpedance techniques. The values of body water assessments in our study were higher in BIA than in BIS. Ethnicity, sex, body mass index, and estimated glomerular filtration rate were associated with these biases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.