We studied 123 patients with malignant peripheral nerve sheath tumours (MPNSTs) between 1979 and 2002. However, 90 occurred sporadically whereas 33 were associated with neurofibromatosis type 1 (NF1). Survival was calculated using Kaplan-Meier survival curves and we used Cox's proportional hazards model to identify independent prognostic factors. A 5-year survival for 110 nonmetastatic patients was 54%; (33% NF1 and 63% sporadic P = .015). Tumour stage and site were significant prognostic indicators after univariate analysis. After multivariate analysis, however, only NF1 (P = .007) and tumour volume more than 200 m (P = .015) remained independent predictors of poor outcome.
We recommend that NF1 be taken into account during MPNST staging.
As the survival rate in the NF group was dependant on tumour volume, routine screening of these patients with FDG PET and/or MRI may be warranted, thereby staging and controlling them at the earliest possible opportunity.
Endoprosthetic replacement of the pelvis is one of the most challenging types of limb-salvage surgery, with a high rate of complications. In an attempt to reduce this and build greater versatility into the reconstruction process, a new type of pelvic endoprosthesis was developed in 2003, based on the old McKee-Farrar prosthesis. This study reviews the outcomes in 27 patients who had an ice-cream cone pelvic prosthesis inserted at two different specialist bone tumour centres in the United Kingdom over the past six years. The indications for treatment included primary bone tumours in 19 patients and metastatic disease in two, and six implants were inserted following failure of a previous pelvic reconstruction. Most of the patients had a P2+P3 resection as classified by Enneking, and most had resection of the ilium above the sciatic notch. The mean age of the patients at operation was 49 years (13 to 81). Complications occurred in ten patients (37.0%), of which dislocation was the most common, affecting four patients (14.8%). A total of three patients (11.1%) developed a deep infection around the prosthesis but all were successfully controlled by early intervention and two patients (7.4%) developed a local recurrence, at the same time as widespread metastases appeared. In one patient the prosthesis was removed for severe pain. This method of treatment is still associated with high morbidity, but early results are promising. Complications are diminishing with increasing experience.
Hereditary multiple exostoses (HME), the most frequent of all skeletal dysplasias, is an autosomal dominant disorder characterized by the presence of multiple exostoses localized mainly at the end of long bones. HME is genetically heterogeneous, with at least three loci, on 8q24.1 (EXT1), 11p11-p13 (EXT2), and 19p (EXT3). Both the EXT1 and EXT2 genes have been cloned recently and define a new family of potential tumor suppressor genes. This is the first study in which mutation screening has been performed for both the EXT1 and EXT2 genes prior to any linkage analysis. We have screened 17 probands with the HME phenotype, for alterations in all translated exons and flanking intronic sequences, in the EXT1 and EXT2 genes, by conformation-sensitive gel electrophoresis. We found the disease-causing mutation in 12 families (70%), 7 (41%) of which have EXT1 mutations and 5 (29%) EXT2 mutations. Together with the previously described 1-bp deletion in exon 6, which is present in 2 of our families, we report five new mutations in EXT1. Two are missense mutations in exon 2 (G339D and R340C), and the other three alterations (a nonsense mutation, a frameshift, and a splicing mutation) are likely to result in truncated nonfunctional proteins. Four new mutations are described in EXT2. A missense mutation (D227N) was found in 2 different families; the other three alterations (two nonsense mutations and one frameshift mutation) lead directly or indirectly to premature stop codons. The missense mutations in EXT1 and EXT2 may pinpoint crucial domains in both proteins and therefore give clues for the understanding of the pathophysiology of this skeletal disorder.
EXT1 and EXT2 are two genes responsible for the majority of cases of hereditary multiple exostoses (HME), a dominantly inherited bone disorder. In order to develop an efficient screening strategy for mutations in these genes, we performed two independent blind screens of EXT1 and EXT2 in 34 unrelated patients with HME, using denaturing high-performance liquid chromatography (DHPLC) and fluorescent single-strand conformation polymorphism analysis (F-SSCP). The mutation likely to cause HME was found in 29 (85%) of the 34 probands: in 22 of these (76%), the mutation was in EXT1; seven patients (24%) had EXT2 mutations. Nineteen of these disease mutations have not been previously reported. Of the 42 different amplicon variants identified in total in the cohort, 40 were detected by DHPLC and 39 by F-SSCP. This corresponds to mutation detection efficiencies of 95% and 93% respectively. We have also found that we can confidently distinguish between different sequence variants in the same fragment using F-SSCP but not DHPLC. In light of this, and the similarly high sensitivities of the two techniques, we propose to continue screening with F-SSCP.
Recent reports have suggested that a delay in the management of type-III supracondylar fractures of the humerus does not affect the outcome. In this retrospective study we examined whether the timing of surgery affected peri-operative complications, or the need for open reduction. There were 171 children with a closed type-III supracondylar fracture of the humerus and no vascular compromise in our study. They were divided into two groups: those treated less than eight hours from presentation to the Accident and Emergency Department (126 children), and those treated more than eight hours from presentation (45 children). There were no differences in the rate of complications between the groups, but children waiting more than eight hours for reduction were more likely to undergo an open reduction (33.3% vs 11.2%, p < 0.05) and there was a weak correlation (p = 0.062) between delay in surgery and length of operating time. Consequently, we would still recommend treating these injuries at the earliest opportunity.
Background:Release and dispersion of particles arising from corrosion and wear of total hip arthroplasty (THA) components has raised concerns about a possible increased risk of cancer. Concerns have been heightened by a recent revival in the use of metal-on-metal (MoM) hip prostheses.Methods:From a linked database of hospital discharge, cancer registration, and mortality records, we selected a cohort of patients who underwent primary THA (1990–2009) or primary resurfacing arthroplasty (mainly 2000–2009) in Scotland, with follow-up to the end of 2010. Available operation codes did not enable us to distinguish MoM THAs. Indirectly standardised incidence ratios (SIRs) were calculated for selected cancers with standardisation for age, sex, deprivation, and calendar period.Results:The study cohort included 71 990 patients yielding 547 001 person-years at risk (PYAR) and 13 946 cancers diagnosed during follow-up. For the total period of observation combined, the risks of all cancers (SIR: 1.05; 95% CI: confidence interval 1.04–1.07), prostate cancer (SIR: 1.07; 95% CI: 1.01–1.14), and multiple myeloma (SIR: 1.22; 95% CI: 1.06–1.41) were increased. These modest increases in risk emerged in the context of effectively multiple tests of statistical significance, and may reflect inadequate adjustment for confounding factors. For 1317 patients undergoing primary resurfacing arthroplasty between 2000 and 2009 (PYAR=5698), the SIR for all cancers (n=39) was 1.23 (95% CI: 0.87–1.68).Conclusion:In the context of previous research, these results do not suggest a major cause for concern. However, the duration of follow-up of patients receiving recently introduced, new-generation MoM prostheses is too short to rule out a genuinely increased risk of cancer entirely.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.