Antibody levels predict vaccine efficacy Symptomatic COVID-19 infection can be prevented by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines. A “correlate of protection” is a molecular biomarker to measure how much immunity is needed to fight infection and is key for successful global immunization programs. Gilbert et al . determined that antibodies are the correlate of protection in vaccinated individuals enrolled in the Moderna COVE phase 3 clinical trial (see the Perspective by Openshaw). By measuring binding and neutralizing antibodies against the viral spike protein, the authors found that the levels of both antibodies correlated with the degree of vaccine efficacy. The higher the antibody level, the greater the protection afforded by the messenger RNA (mRNA) vaccine. Antibody levels that predict mRNA vaccine efficacy can therefore be used to guide vaccine regimen modifications and support regulatory approvals for a broader spectrum of the population. —PNK
Background: In the Coronavirus Efficacy (COVE) trial, estimated mRNA-1273 vaccine efficacy against coronavirus disease-19 (COVID-19) was 94%. SARS-CoV-2 antibody measurements were assessed as correlates of COVID-19 risk and as correlates of protection. Methods: Through case-cohort sampling, participants were selected for measurement of four serum antibody markers at Day 1 (first dose), Day 29 (second dose), and Day 57: IgG binding antibodies (bAbs) to Spike, bAbs to Spike receptor-binding domain (RBD), and 50% and 80% inhibitory dilution pseudovirus neutralizing antibody titers calibrated to the WHO International Standard (cID50 and cID80). Participants with no evidence of previous SARS-CoV-2 infection were included. Cox regression assessed in vaccine recipients the association of each Day 29 or 57 serologic marker with COVID-19 through 126 or 100 days of follow-up, respectively, adjusting for risk factors. Results: Day 57 Spike IgG, RBD IgG, cID50, and cID80 neutralization levels were each inversely correlated with risk of COVID-19: hazard ratios 0.66 (95% CI 0.50, 0.88; p=0.005); 0.57 (0.40, 0.82; p=0.002); 0.41 (0.26, 0.65; p<0.001); 0.35 (0.20, 0.60; p<0.001) per 10-fold increase in marker level, respectively, multiplicity adjusted P-values 0.003-0.010. Results were similar for Day 29 markers (multiplicity adjusted P-values <0.001-0.003). For vaccine recipients with Day 57 reciprocal cID50 neutralization titers that were undetectable (<2.42), 100, or 1000, respectively, cumulative incidence of COVID-19 through 100 days post Day 57 was 0.030 (0.010, 0.093), 0.0056 (0.0039, 0.0080), and 0.0023 (0.0013, 0.0036). For vaccine recipients at these titer levels, respectively, vaccine efficacy was 50.8% (-51.2, 83.0%), 90.7% (86.7, 93.6%), and 96.1% (94.0, 97.8%). Causal mediation analysis estimated that the proportion of vaccine efficacy mediated through Day 29 cID50 titer was 68.5% (58.5, 78.4%). Conclusions: Binding and neutralizing antibodies correlated with COVID-19 risk and vaccine efficacy and likely have utility in predicting mRNA-1273 vaccine efficacy against COVID-19. Trial registration number: COVE ClinicalTrials.gov number, NCT04470427
Plasmonic nanoantennas are versatile tools for coherently controlling and directing light on the nanoscale. For these antennas, current fabrication techniques such as electron beam lithography (EBL) or focused ion beam (FIB) milling with Ga(+)-ions routinely achieve feature sizes in the 10 nm range. However, they suffer increasingly from inherent limitations when a precision of single nanometers down to atomic length scales is required, where exciting quantum mechanical effects are expected to affect the nanoantenna optics. Here, we demonstrate that a combined approach of Ga(+)-FIB and milling-based He(+)-ion lithography (HIL) for the fabrication of nanoantennas offers to readily overcome some of these limitations. Gold bowtie antennas with 6 nm gap size were fabricated with single-nanometer accuracy and high reproducibility. Using third harmonic (TH) spectroscopy, we find a substantial enhancement of the nonlinear emission intensity of single HIL-antennas compared to those produced by state-of-the-art gallium-based milling. Moreover, HIL-antennas show a vastly improved polarization contrast. This superior nonlinear performance of HIL-derived plasmonic structures is an excellent testimonial to the application of He(+)-ion beam milling for ultrahigh precision nanofabrication, which in turn can be viewed as a stepping stone to mastering quantum optical investigations in the near-field.
17The pore size distribution and architecture in gas shale were studied using a combination of 18 small-angle neutron scattering (SANS), mercury injection capillary pressure (MICP), and helium 19 ion microscopy (HIM). SANS analysis shows that the pore size population is not a power-law 20 distribution across many length scales, typical of sedimentary rocks, but contains an anomalous 21 population of pores on-the-order ~2 nm, housed primarily in the organic matter. A model is 22presented showing how a "foamy porosity" with such a characteristic size is a direct result of 23 diagenetic evolution of kerogen. Cross-linking of the kerogen combined with phase separation 24 of gas/oil, leads to arrested coarsening with a length scale set by cross-length density. These 25 pore populations determined by the scattering model are directly supported by HIM images. 26Pore connectivity determined through pore size-to-pore-throat analysis, suggests that inter pore 27 connections are also distinct from typical sedimentary rocks. The pore/throat ratio, unlike the 28 simple ratios predicted from sphere packing and found for clastic rocks, is nearly constant over 29 all pore sizes. Kerogen diagenesis is a recognized source of excess internal pressure. When this 30 pressure causes failure of the material surrounding the kerogen to create escape pathways for the 31 phase-separated fluid, it is likely that escape pathways will connect intergranular porosity via 32 microfractures, producing the relatively narrow aperture size distribution. 33 34
Scanning Electron Microscopy (SEM) has long been the standard in imaging the sub-micrometer surface ultrastructure of both hard and soft materials. In the case of biological samples, it has provided great insights into their physical architecture. However, three of the fundamental challenges in the SEM imaging of soft materials are that of limited imaging resolution at high magnification, charging caused by the insulating properties of most biological samples and the loss of subtle surface features by heavy metal coating. These challenges have recently been overcome with the development of the Helium Ion Microscope (HIM), which boasts advances in charge reduction, minimized sample damage, high surface contrast without the need for metal coating, increased depth of field, and 5 angstrom imaging resolution. We demonstrate the advantages of HIM for imaging biological surfaces as well as compare and contrast the effects of sample preparation techniques and their consequences on sub-nanometer ultrastructure.
Since the discovery of the high-transition-temperature superconductors (HTSs), researchers have explored many methods to fabricate superconducting tunnel junctions from these materials for basic science purposes and applications. HTS circuits operating at liquid-nitrogen temperatures (∼77 K) would significantly reduce power requirements in comparison with those fabricated from conventional superconductors. The difficulty is that the superconducting coherence length is very short and anisotropic in these materials, typically ∼2 nm in the a-b plane and ∼0.2 nm along the c axis. The electrical properties of Josephson junctions are therefore sensitive to chemical variations and structural defects on atomic length scales. To make multiple uniform HTS junctions, control at the atomic level is required. In this Letter we demonstrate all-HTS Josephson superconducting tunnel junctions created by using a 500-pm-diameter focused beam of helium ions to directly write tunnel barriers into YBa2Cu3O(7-δ) (YBCO) thin films. We demonstrate the ability to control the barrier properties continuously from conducting to insulating by varying the irradiation dose. This technique could provide a reliable and reproducible pathway for scaling up quantum-mechanical circuits operating at liquid-nitrogen temperatures, as well as an avenue to conduct novel planar superconducting tunnelling studies for basic science.
Optical antenna structures have revolutionized the field of nano-optics by confining light to deep subwavelength dimensions for spectroscopy and sensing. In this work, we fabricated coaxial optical antennae with sub-10-nanometer critical dimensions using helium ion lithography (HIL). Wavelength dependent transmission measurements were used to determine the wavelength-dependent optical response. The quality factor of 11 achieved with our HIL fabricated structures matched the theoretically predicted quality factor for the idealized flawless gold resonators calculated by finite-difference time-domain (FDTD). For comparison, coaxial antennae with 30 nm critical dimensions were fabricated using both HIL and the more common Ga focus ion beam lithography (Ga-FIB). The quality factor of the Ga-FIB resonators was 60% of the ideal HIL results for the same design geometry due to limitations in the Ga-FIB fabrication process.
Helium ion scanning microscopy is a novel imaging technology with the potential to provide sub-nanometer resolution images of uncoated biological tissues. So far, however, it has been used mainly in materials science applications. Here, we took advantage of helium ion microscopy to explore the epithelium of the rat kidney with unsurpassed image quality and detail. In addition, we evaluated different tissue preparation methods for their ability to preserve tissue architecture. We found that high contrast, high resolution imaging of the renal tubule surface is possible with a relatively simple processing procedure that consists of transcardial perfusion with aldehyde fixatives, vibratome tissue sectioning, tissue dehydration with graded methanol solutions and careful critical point drying. Coupled with the helium ion system, fine details such as membrane texture and membranous nanoprojections on the glomerular podocytes were visualized, and pores within the filtration slit diaphragm could be seen in much greater detail than in previous scanning EM studies. In the collecting duct, the extensive and striking apical microplicae of the intercalated cells were imaged without the shrunken or distorted appearance that is typical with conventional sample processing and scanning electron microscopy. Membrane depressions visible on principal cells suggest possible endo- or exocytotic events, and central cilia on these cells were imaged with remarkable preservation and clarity. We also demonstrate the use of colloidal gold probes for highlighting specific cell-surface proteins and find that 15 nm gold labels are practical and easily distinguishable, indicating that external labels of various sizes can be used to detect multiple targets in the same tissue. We conclude that this technology represents a technical breakthrough in imaging the topographical ultrastructure of animal tissues. Its use in future studies should allow the study of fine cellular details and provide significant advances in our understanding of cell surface structures and membrane organization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.