To enhance our understanding of liquids in contact with rough surfaces, a systematic study has been carried out in which water contact angle measurements were performed on a wide variety of rough surfaces with precisely controlled surface chemistry. Surface morphologies consisted of sandblasted glass slides as well as replicas of acid-etched, sandblasted titanium, lotus leaves, and photolithographically manufactured golf-tee shaped micropillars (GTMs). The GTMs display an extraordinarily stable, Cassie-type hydrophobicity, even in the presence of hydrophilic surface chemistry. Due to pinning effects, contact angles on hydrophilic rough surfaces are shifted to more hydrophobic values, unless roughness or surface energy are such that capillary forces become significant, leading to complete wetting. The observed hydrophobicity is thus not consistent with the well-known Wenzel equation. We have shown that the pinning strength of a surface is independent of the surface chemistry, provided that neither capillary forces nor air enclosure are involved. In addition, pinning strength can be described by the axis intercept of the cosine-cosine plot of contact angles for rough versus flat surfaces with the same surface chemistries.
Metal-on-metal (MoM) bearings are at the forefront in hip resurfacing arthroplasty. Because of their good wear characteristics and design flexibility, MoM bearings are gaining wider acceptance with market share reaching nearly 10% worldwide. However, concerns remain regarding potential detrimental effects of metal particulates and ion release. Growing evidence is emerging that the local cell response is related to the amount of debris generated by these bearing couples. Thus, an urgent clinical need exists to delineate the mechanisms of debris generation to further reduce wear and its adverse effects. In this study, we investigated the microstructural and chemical composition of the tribochemical reaction layers forming at the contacting surfaces of metallic bearings during sliding motion. Using X-ray photoelectron spectroscopy and transmission electron microscopy with coupled energy dispersive X-ray and electron energy loss spectroscopy, we found that the tribolayers are nanocrystalline in structure, and that they incorporate organic material stemming from the synovial fluid. This process, which has been termed ''mechanical mixing,'' changes the bearing surface of the uppermost 50 to 200 nm from pure metallic to an organic composite material. It hinders direct metal contact (thus preventing adhesion) and limits wear. This novel finding of a mechanically mixed zone of nanocrystalline metal and organic constituents provides the basis for understanding particle release and may help in identifying new strategies to reduce MoM wear. ß
No statistical difference between implants could be demonstrated with any of the methods used. The limited number of animals per group, however, does not allow to conclude that there is no difference in osseointegration between the two types of implants, although the data tend to suggest such a trend.
Bearing surface wear and periprosthetic osteolysis due to wear particles are among the most common reasons for joint replacement failure. A murine calvarial model of wear particle-induced osteolysis has been used to identify different biologic factors associated with this problem and to test nonsurgical methods of modulating the host response to particulate debris. This model has utilized titanium particles, however, in clinical practice the most common source of particulate debris is polyethylene particles from bearing surface wear. We now report a calvarial model of wear particle-induced osteolysis based on commercially available polyethylene particles. We found that compared to sham surgery osteoclast recruitment and bone resorption can be induced by introduction of the titanium particles or polyethylene particles. However, bone resorption was significantly higher with polyethylene particles compared to titanium particles 0, = 0.02).We consider the polyethylene based murine calvarial model of wear particle-induced osteolysis a reliable and clinically relevant tool to understand the host factors and potential pharmacologic interventions that can influence wear debris generated osteolysis. This model might serve as an extension of the well-established titanium based bone resorption model.
The results indicate that there was no difference in osseointegration between ZrO2 implants and Ti-SLA controls regarding peri-implant bone density and BIC ratio.
BackgroundConflicting reports in the literature have raised the question whether radial extracorporeal shock wave therapy (rESWT) devices and vibrating massage devices have similar energy signatures and, hence, cause similar bioeffects in treated tissues.Methods and FindingsWe used laser fiber optic probe hydrophone (FOPH) measurements, high-speed imaging and x-ray film analysis to compare fundamental elements of the energy signatures of two rESWT devices (Swiss DolorClast; Electro Medical Systems, Nyon, Switzerland; D-Actor 200; Storz Medical, Tägerwillen, Switzerland) and a vibrating massage device (Vibracare; G5/General Physiotherapy, Inc., Earth City, MO, USA). To assert potential bioeffects of these treatment modalities we investigated the influence of rESWT and vibrating massage devices on locomotion ability of Caenorhabditis elegans (C. elegans) worms.ResultsFOPH measurements demonstrated that both rESWT devices generated acoustic waves with comparable pressure and energy flux density. Furthermore, both rESWT devices generated cavitation as evidenced by high-speed imaging and caused mechanical damage on the surface of x-ray film. The vibrating massage device did not show any of these characteristics. Moreover, locomotion ability of C. elegans was statistically significantly impaired after exposure to radial extracorporeal shock waves but was unaffected after exposure of worms to the vibrating massage device.ConclusionsThe results of the present study indicate that both energy signature and bioeffects of rESWT devices are fundamentally different from those of vibrating massage devices.Clinical RelevancePrior ESWT studies have shown that tissues treated with sufficient quantities of acoustic sound waves undergo cavitation build-up, mechanotransduction, and ultimately, a biological alteration that “kick-starts” the healing response. Due to their different treatment indications and contra-indications rESWT devices cannot be equated to vibrating massage devices and should be used with due caution in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.