Diaphragm atrophy is present in children on mechanical ventilation for acute respiratory failure. Diaphragm contractility, measured as thickening fraction, is strongly correlated with spontaneous breathing fraction. The combination of exposure to neuromuscular blockade infusion with low overall spontaneous breathing fraction is associated with a greater degree of atrophy.
Objectives: Diaphragm atrophy is evident during invasive ventilation for pediatric acute respiratory failure, but with unknown significance. We hypothesized that diaphragm atrophy in pediatric acute respiratory failure is associated with prolonged noninvasive positive pressure ventilation following extubation. Design: Prospective observational study. Setting: Single-center academic PICU. Patients: Invasively ventilated children with acute respiratory failure. Interventions: Diaphragm ultrasound was performed within 36 hours after intubation and repeated within 48 hours preceding extubation. Rapid shallow breathing index at 15 and 30 minutes of a spontaneous breathing trial and negative inspiratory force were collected in a subset of patients concurrently with the ultrasound measurements. Measurements and Main Results: Diaphragm thickness at end-expiration was measured to assess for diaphragm atrophy during mechanical ventilation. Percentage change in diaphragm thickness at end-expiration was defined as baseline diaphragm thickness at end-expiration minus final, preextubation diaphragm thickness at end-expiration divided by baseline diaphragm thickness at end-expiration. The primary outcome measure was duration of noninvasive positive pressure ventilation following extubation with prolonged use defined as noninvasive positive pressure ventilation use for greater than 24 hours postextubation. Among 56 children, 47 (median age, 15.5 mo; interquartile range, 6–53 mo) had diaphragm thickness at end-expiration measured within 48 hours prior to extubation. Fourteen (30%) had prolonged noninvasive positive pressure ventilation use with median duration 110 hours (interquartile range, 52–130 hr). The median percentage change of diaphragm thickness at end-expiration from baseline among those with and without prolonged noninvasive positive pressure ventilation use was –20% (interquartile range, –32% to –10%) versus –7% (interquartile range, –21% to 0%) (p = 0.04). Conclusions: Diaphragm atrophy is associated with prolonged postextubation noninvasive positive pressure ventilation in children with acute respiratory failure. Serial bedside diaphragm ultrasound may identify children at risk for prolonged noninvasive positive pressure ventilation use after extubation.
Point-of-care ultrasound is currently widely used across the landscape of pediatric care. Ultrasound machines are now smaller, are easier to use, and have much improved image quality. They have become common in emergency departments, ICUs, inpatient wards, and outpatient clinics. Recent growth of supportive evidence makes a strong case for using point-of-care ultrasound for pediatric interventions such as vascular access (in particular, central-line placement), lumbar puncture, fluid drainage (paracentesis, thoracentesis, pericardiocentesis), suprapubic aspiration, and soft tissue incision and drainage. Our review of this evidence reveals that point-of-care ultrasound has become a powerful tool for improving procedural success and patient safety. Pediatric patients and clinicians performing procedures stand to benefit greatly from point-of-care ultrasound, because seeing is believing.
The use of point of care ultrasound (POCUS) at the bedside has increased dramatically within emergency medicine and in critical care. Applications of POCUS have spread to include diaphragmatic assessments in both adults and children. Diaphragm POCUS can be used to assess for diaphragm dysfunction (DD) and atrophy or to guide ventilator titration and weaning. Quantitative, semi-quantitative and qualitative measurements of diaphragm thickness, diaphragm excursion, and diaphragm thickening fraction provide objective data related to DD and atrophy. The potential for quick, noninvasive, and repeatable bedside diaphragm assessments has led to a growing amount of literature on diaphragm POCUS. To date, there are no reviews of the current state of diaphragm POCUS in pediatric critical care. The aims of this narrative review are to summarize the current literature regarding techniques, reference values, applications, and future innovations of diaphragm POCUS in critically ill children. A summary of current practice and future directions will be discussed.
Objectives: To assess focused cardiac ultrasound impact on clinician hemodynamic characterization of patients with suspected septic shock as well as expert-generated focused cardiac ultrasound algorithm performance. Design: Retrospective, observational study. Setting: Single-center, noncardiac PICU. Patients: Less than 18 years old receiving focused cardiac ultrasound study within 72 hours of sepsis pathway initiation from January 2014 to December 2016. Interventions: Hemodynamics of patients with suspected septic shock were characterized as fluid responsive, myocardial dysfunction, obstructive physiology, and/or reduced systemic vascular resistance by a bedside clinician before and immediately following focused cardiac ultrasound performance. The clinician’s post-focused cardiac ultrasound hemodynamic assessments were compared with an expert-derived focused cardiac ultrasound algorithmic hemodynamic interpretation. Subsequent clinical management was assessed for alignment with focused cardiac ultrasound characterization and association with patient outcomes. Measurements and Main Results: Seventy-one patients with suspected septic shock (median, 4.7 yr; interquartile range, 1.6–8.1) received clinician performed focused cardiac ultrasound study within 72 hours of sepsis pathway initiation (median, 2.1 hr; interquartile range, –1.5 to 11.8 hr). Two patients did not have pre-focused cardiac ultrasound and 23 patients did not have post-focused cardiac ultrasound hemodynamic characterization by clinicians resulting in exclusion from related analyses. Post-focused cardiac ultrasound clinician hemodynamic characterization differed from pre-focused cardiac ultrasound characterization in 67% of patients (31/46). There was substantial concordance between clinician’s post-focused cardiac ultrasound and algorithm hemodynamic characterization (33/48; κ = 0.66; CI, 0.51–0.80). Fluid responsive (κ = 0.62; CI, 0.40–0.84), obstructive physiology (к = 0.87; CI, 0.64–1.00), and myocardial dysfunction (1.00; CI, 1.00–1.00) demonstrated substantial to perfect concordance. Management within 4 hours of focused cardiac ultrasound aligned with algorithm characterization in 53 of 71 patients (75%). Patients with aligned management were less likely to have a complicated course (14/52, 27%) compared with misaligned management (8/19, 42%; p = 0.25). Conclusions: Incorporation of focused cardiac ultrasound in the evaluation of patients with suspected septic shock frequently changed a clinician’s characterization of hemodynamics. An expert-developed algorithm had substantial concordance with a clinician’s post-focused cardiac ultrasound hemodynamic characterization. Management aligned with algorithm characterization may improve outcomes in children with suspected septic shock.
Objectives: Determine level of agreement among clinical signs of shock type, identify which signs clinicians prioritize to determine shock type and select vasoactive medications, and test the association of shock type-vasoactive mismatch with prolonged organ dysfunction or death (complicated course). Design: Retrospective observational study. Setting: Single large academic PICU. Patients: Patients less than 18 years treated on a critical care sepsis pathway between 2012 and 2016. Interventions: None. Measurements and Main Results: Agreement among clinical signs (extremity temperature, capillary refill, pulse strength, pulse pressure, and diastolic blood pressure) was measured using Fleiss and Cohen’s κ. Association of clinical signs with shock type and shock type-vasoactive mismatch (e.g., cold shock treated with vasopressor rather than inotrope) with complicated course was determined using multivariable logistic regression. Of 469 patients, clinicians determined 307 (65%) had warm and 162 (35%) had cold shock. Agreement across all clinical signs was low (κ, 0.25; 95% CI, 0.20–0.30), although agreement between extremity temperature, capillary refill, and pulse strength was better than with pulse pressure and diastolic blood pressure. Only extremity temperature (adjusted odds ratio, 26.6; 95% CI, 15.5–45.8), capillary refill (adjusted odds ratio, 15.7; 95% CI, 7.9–31.3), and pulse strength (adjusted odds ratio, 21.3; 95% CI, 8.6–52.7) were associated with clinician-documented shock type. Of the 86 patients initiated on vasoactive medications during the pathway, shock type was discordant from vasoactive medication (κ, 0.14; 95% CI, –0.03 to 0.31) and shock type-vasoactive mismatch was not associated with complicated course (adjusted odds ratio, 0.3; 95% CI, 0.1–1.02). Conclusions: Agreement was low among common clinical signs used to characterize shock type, with clinicians prioritizing extremity temperature, capillary refill, and pulse strength. Although clinician-assigned shock type was often discordant with vasoactive choice, shock type-vasoactive mismatch was not associated with complicated course. Categorizing shock based on clinical signs should be done cautiously.
Healthcare regulatory bodies have escalated concerns regarding the use of point-of-care ultrasound by nonradiology and noncardiology physicians. A recently published PCCM Perspective identified that data do not support many of these concerns and addressed common misconceptions associated with point-of-care ultrasound use in the critical care setting. Indeed, the global point-of-care ultrasound community and specifically the pediatric critical care community have the opportunity to be leaders in demonstrating how to translate new skills and technologies to the bedside in a safe and effective manner. We seek to extend the conversation and propose next steps in supporting integration of point-of-care ultrasound in pediatric critical care practice.
Ultrasound technology is available in many pediatric perioperative settings. There is an increasing number of ultrasound applications for anesthesiologists which may enhance clinical performance, procedural safety, and patient outcomes. This review highlights the literature and experience supporting focused ultrasound applications in the pediatric perioperative setting across varied disciplines including anesthesiology. The review also suggests strategies for building educational and infrastructural systems to translate this technology into clinical practice. K E Y W O R D S anesthesiology, echocardiography, education, nerve block, patient safety, ultrasonography | 673 CONLON et aL. How to cite this article: Conlon TW, Lin EE, Bruins BB, et al. Getting to know a familiar face: Current and emerging focused ultrasound applications for the perioperative setting. Pediatr
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.