SummaryUltrasonography may offer significant advantages in regional anaesthesia of the upper and lower limbs. It is not known if the same advantages demonstrated in adults also apply to children. We therefore performed a prospective, randomised study comparing ultrasound visualisation to conventional nerve stimulation for infraclavicular brachial plexus anasesthesia in children. Forty children scheduled for arm and forearm surgery underwent infraclavicular brachial plexus blocks with ropivacaine 0.5 ml.kg )1 guided by either nerve stimulation or ultrasound visualisation.Evaluated parameters included sensory block quality, sensory block distribution and motor block. All surgical procedures were performed under brachial plexus anaesthesia alone. Direct ultrasound visualisation was successful in all cases and was associated with significant improvements when compared with the use of nerve stimulation: lower visual analogue scores during puncture (p = 0.03), shorter mean (median) sensory onset times (9 (5-15) min vs. 15 (5-25) min, p < 0.001), longer sensory block durations (384 (280-480) min vs. 310 (210-420) min, p < 0.001), and better sensory and motor block scores 10 min afrter block insertion. Ultrasound visualisation offers faster sensory and motor responses and a longer duration of sensory blockade than nerve stimulation in children undergoing infraclavicular brachial plexus blocks. In addition, the pain associated with nerve stimulation due to muscle contractions at the time of insertion is eliminated.
Levobupivacaine, the pure S(-)-enantiomer of racemic bupivacaine is an equally effective local anesthetic for spinal anesthesia compared with racemic bupivacaine.
Ultrasonography is a useful aid to verify epidural placement of local anaesthetic agents and epidural catheters in children. Advantages include a reduction in bone contacts, faster epidural placement, direct visualization of neuraxial structures and the spread of local anaesthetic inside the epidural space. Ultrasound guidance requires additional training and good manual skills, and should only be used once experience in ultrasound-guided techniques of regional anaesthesia has been acquired.
These findings suggest responder and non-responder behaviour is a result of the addition of clonidine.
In patients with acute respiratory distress syndrome (ARDS), permissive hypercapnia is a strategy to decrease airway pressures to prevent ventilator-induced lung damage by lowering tidal volumes and tolerating higher arterial carbon dioxide tension. However, in experimental studies hypercapnia impairs myocardial contractility and hemodynamic function. We investigated the effect of short-term permissive hypercapnia on myocardial contractility and hemodynamics in patients with ARDS. We hypothesized that the administration of tromethamine (THAM), a buffer which does not increase carbon dioxide production, would modify these changes. In 12 patients with ARDS, permissive hypercapnia was implemented for 2 h with a target Pa(CO(2))of 80 mm Hg. Patients were randomized to have respiratory acidosis corrected by THAM (pH-corrected group), or not corrected (pH-uncorrected group). Hemodynamic responses were measured, and transesophageal echocardiography (TEE) was used to determine myocardial contractility. Permissive hypercapnia resulted in significant decreases in systemic vascular resistance (SVR) and increases in cardiac output (Q). Myocardial contractility decreased in both groups but significantly less in the pH-corrected group (approximately 10%) than in the pH-uncorrected group (approximately 18%, p < 0.05). Mean arterial pressure decreased and mean pulmonary arterial pressure increased significantly only in the pH-uncorrected group. All values returned to baseline conditions 1 h after permissive hypercapnia was terminated. Our study demonstrates a reversible depression of myocardial contractility and hemodynamic alterations during rapid permissive hypercapnia which were attenuated by buffering with THAM. This may have applicability to the clinical strategy of permissive hypercapnia and allow the benefit of decreased airway pressures to be realized while minimizing the adverse hemodynamic effects of hypercapnic acidosis.
We demonstrate by using magnetic resonance imaging that the mechanism of a three-in-one block is one of lateral, caudal, and slight medial spread of a local anesthetic with subsequent blockade of the femoral, the lateral femoral cutaneous, and the anterior branch of the obturator nerves. It does not involve cephalad spread of the local anesthetic with blockade of the lumbar plexus.
Total hip or knee replacement surgeries are common orthopedic interventions that can be performed with spinal anesthesia (SA) or general anesthesia (GA). No study has investigated the economic aspects associated with the two anesthetic techniques for this common surgery. We randomized 40 patients to receive either SA or GA and analyzed the drug and supply costs for anesthesia und recovery. Anesthesia-related times, hemodynamic variables, and pain scores were also recorded. Total costs per case without personnel costs were almost half in the SA group compared with the GA group; this was a result of less cost for anesthesia (P < 0.01) and for recovery (P < 0.05). This finding was supported by a sensitivity analysis. There were no relevant differences regarding anesthesia-related times. Patients in the GA group were admitted to the postanesthesia care unit with a higher pain score and needed more analgesics than patients in the SA group (both P < 0.01). We conclude that SA is a more cost-effective alternative to GA in patients undergoing hip or knee replacement, as it is associated with lower fixed and variable costs. Moreover, SA seems to be more effective, as patients in the SA group showed lower postoperative pain scores during their stay in the postanesthesia care unit.
Objective To determine which bedside method of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity.Design Prospective randomised blinded study.Setting Department of anaesthesia in tertiary academic hospital.Participants 160 consecutive patients (American Society of Anesthesiologists category I or II) aged 19-75 scheduled for elective gynaecological or urological surgery.Interventions Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube was fibreoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. To determine whether the tube was properly positioned in the trachea, in each patient first year residents and experienced anaesthetists were randomly assigned to independently perform bilateral auscultation of the chest (auscultation); observation and palpation of symmetrical chest movements (observation); estimation of the position of the tube by the insertion depth (tube depth); or a combination of all three (all three).Main outcome measures Correct and incorrect judgments of endotracheal tube position.Results 160 patients underwent 320 observations by experienced and inexperienced anaesthetists. First year residents missed endobronchial intubation by auscultation in 55% of cases and performed significantly worse than experienced anaesthetists with this bedside test (odds ratio 10.0, 95% confidence interval 1.4 to 434). With a sensitivity of 88% (95% confidence interval 75% to 100%) and 100%, respectively, tube depth and the three tests combined were significantly more sensitive for detecting endobronchial intubation than auscultation (65%, 49% to 81%) or observation(43%, 25% to 60%) (P<0.001). The four tested methods had the same specificity for ruling out endobronchial intubation (that is, confirming correct tracheal intubation). The average correct tube insertion depth was 21 cm in women and 23 cm in men. By inserting the tube to these distances, however, the distal tip of the tube was less than 2.5 cm away from the carina (the recommended safety distance, to prevent inadvertent endobronchial intubation with changes in the position of the head in intubated patients) in 20% (24/118) of women and 18% (7/42) of men. Therefore optimal tube insertion depth was considered to be 20 cm in women and 22 cm in men.Conclusion Less experienced clinicians should rely more on tube insertion depth than on auscultation to detect inadvertent endobronchial intubation. But even experienced physicians will benefit from inserting tubes to 20-21 cm in women and 22-23 cm in men, especially when high ambient noise precludes accurate auscultation (such as in emergency situations or helicopter transport). The highest sensitivity and specificity for ruling out endobronchial intubation, however, is achieved by combining tube depth, auscultation of the lungs, and observation of...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.