Groundwater, as the world's most important reserve of available fresh water, is known to be affected by urbanization. Managing this resource in a sustainable way is critical for water resource management. Groundwater recharge rates in urban areas remain however still poorly understood and under-researched and knowledge about these rates and their expected changes under increasing urbanization is therefore of primary importance. This study aims to give insight into urban groundwater recharge by performing water budget calculations for four different time periods for an urban study site in northern Switzerland. In order to take into account uncertainty in parameter values a Monte Carlo (MC) approach was carried out. Our study highlights a strong positive correlation between groundwater recharge rates and the extent of the urban area. In detail, at the study site urban areas expanded from 6% in 1880 to 44% in 2009, leading to an increase in the mean groundwater recharge rate. However, the increase amount in recharge remains uncertain and varies between 29% and 67% depending on the parameter combination originating from the MC approach. Based on our water budget calculations, the transformation of natural landscapes into impervious areas leads to an increase in groundwater recharge rates due to the reduction of evapotranspiration that more than compensates for the increase in runoff. Furthermore, water main leakages contribute to an increase in recharge rates. Overall, we demonstrate that a better understanding of groundwater recharge changes in urban areas is required to move towards a sustainable water management. We hope that this example will encourage the hydrogeological community to pay more attention to urban groundwater recharge. Highlights • Urban groundwater recharge rate assessment through water budget calculations • Urbanization leads to a reduction of evapotranspiration • Water leakages contribute to recharge rates increase (up to 10% at the study site) • Increasing groundwater recharge rates due to urbanization at Dübendorf, Switzerland
Knowledge about the residence times of artificially infiltrated water into an aquifer and the resulting flow paths is essential to developing groundwater-management schemes. To obtain this knowledge, a variety of tracers can be used to study residence times and gain information about subsurface processes. Although a variety of tracers exists, their interpretation can differ considerably due to subsurface heterogeneity, underlying assumptions, and sampling and analysis limitations. The current study systematically assesses information gained from seven different tracers during a pumping experiment at a site where drinking water is extracted from an aquifer close to contaminated areas and where groundwater is artificially recharged by infiltrating surface water. We demonstrate that the groundwater residence times estimated using dye and heat tracers are comparable when the thermal retardation for the heat tracer is considered. Furthermore, major ions, acesulfame, and stable isotopes (δH and δO) show that mixing of infiltrated water and groundwater coming from the regional flow path occurred and a vertical stratification of the flow system exist. Based on the concentration patterns of dissolved gases (He, Ar, Kr, N, and O) and chlorinated solvents (e.g., tetrachloroethene), three temporal phases are observed in the ratio between infiltrated water and regional groundwater during the pumping experiment. Variability in this ratio is significantly related to changes in the pumping and infiltration rates. During constant pumping rates, more infiltrated water was extracted, which led to a higher dilution of the regional groundwater. An infiltration interruption caused however, the ratio to change and more regional groundwater is extracted, which led to an increase in all concentrations. The obtained results are discussed for each tracer considered and its strengths and limitations are illustrated. Overall, it is demonstrated that aquifer heterogeneity and various subsurface processes necessitate application of multiple tracers to quantify uncertainty when identifying flow processes.
A null‐space Monte‐Carlo (NSMC) approach was applied to account for uncertainty in the calibration of the hydraulic conductivity (K) field for a three‐dimensional groundwater flow model of a major water supply system in Switzerland. The approach generates different parameter realizations of the K field using the pilot point methodology. Subsequently, particle tracking (PT) was applied to each calibrated model, and the resulting particles are interpreted as the spatial pathline density distribution of multiple sources. The adopted approach offers advantages over classical PT which does not provide a means for treating uncertainty originating from the incomplete description of subsurface heterogeneity. Uncertainty in the K field is shown to strongly influence the spatial pathline distribution. Pathline spreading is particularly evident in locations where the information content of the head observations does not sufficiently constrain the estimated parameters. Despite the predictive uncertainty, the pumped drinking water at the study site is most likely dominated by artificially‐infiltrated groundwater originating from the local infiltration canals. The model suggests that within the well field, the central pumping wells could be extracting regional groundwater, although the probability is relatively low. Nevertheless, a rigorous uncertainty assessment is still required since only a few realizations resulted in flow paths that support the field observations. Model results should therefore not be based on only one model realization; rather, an uncertainty analysis should be carried out to provide a sufficiently large suite of equally probable simulations that include all potential sources and pathways.
Stable isotopes of water, organic micropollutants and hydrochemistry data are powerful tools for identifying different water types in areas where knowledge of the spatial distribution of different groundwater is critical for water resource management. An important question is how the assessments change if only one or a subset of these tracers is used. In this study, we estimate spatial artificial infiltration along an infiltration system with stage-discharge relationships and classify different water types based on the mentioned hydrochemistry data for a drinking water production area in Switzerland. Managed aquifer recharge via surface water that feeds into the aquifer creates a hydraulic barrier between contaminated groundwater and drinking water wells. We systematically compare the information from the aforementioned tracers and illustrate differences in distribution and mixing ratios. Despite uncertainties in the mixing ratios, we found that the overall spatial distribution of artificial infiltration is very similar for all the tracers. The highest infiltration occurred in the eastern part of the infiltration system, whereas infiltration in the western part was the lowest. More balanced infiltration within the infiltration system could cause the elevated groundwater mound to be distributed more evenly, preventing the natural inflow of contaminated groundwater. Dedicated to Professor Peter Fritz on the occasion of his 80th birthday.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.