Knowledge of human blood-flow waveforms is required for in vitro investigations and numerical modelling. Parameters of interest include: velocity and flow waveform shapes, inter- and intra-subject variability and frequency content. We characterized the blood-velocity waveforms in the left and right common carotid arteries (CCAs) of 17 normal volunteers (24 to 34 years), analysing 3560 cardiac cycles in total. Instantaneous peak-velocity (Vpeak) measurements were obtained using pulsed-Doppler ultrasound with simultaneous collection of ECG data. An archetypal Vpeak waveform was created using velocity and timing parameters at waveform feature points. We report the following timing (post-R-wave) and peak-velocity parameters: cardiac interbeat interval (T(RR)) = 0.917 s (intra-subject standard deviation = +/- 0.045 s); cycle-averaged peak-velocity (V(CYC)) = 38.8 cm s(-1) (+/-1.5 cm s(-1)); maximum systolic Vpeak = 108.2 cm s(-1) (+/-3.8 cm s(-1)) at 0.152 s (+/-0.008 s); dicrotic notch Vpeak = 19.4 cm s(-1) (+/-2.9 cm s(-1)) at 0.398 s (+/-0.007 s). Frequency components below 12 Hz constituted 95% of the amplitude spectrum. Flow waveforms were computed from Vpeak by analytical solution of Womersley flow conditions (derived mean flow = 6.0 ml s(-1)). We propose that realistic, pseudo-random flow waveform sequences can be generated for experimental studies by varying, from cycle to cycle, only T(RR) and V(CYC) of a single archetypal waveform.
To examine the early changes of articular cartilage and subchondral bone in the DMM mouse model of osteoarthritis, mice were subjected to DMM or SHAM surgery and sacrificed at 2-, 5- and 10-week post-surgery. Catwalk gait analyses, Micro-Computed Tomography, Toluidine Blue, Picrosirius Red and Tartrate-Resistant Acid Phosphatase (TRAP) staining were used to investigate gait patterns, joint morphology, subchondral bone, cartilage, collagen organization and osteoclasts activity, respectively. Results showed OA progressed over 10-week time-course. Gait disparity occurred only at 10-week post-surgery. Osteophyte formed at 2-week post-surgery. BMDs of DMM showed no statistical differences comparing to SHAM at 2 weeks, but BV/TV is much higher in DMM mice. Increased BMD was clearly found at 5- and 10-week post-surgery in DMM mice. TRAP staining showed increased osteoclast activity at the site of osteophyte formation of DMM joints at 5- and 10-week time points. These results showed that subchondral bone turnover might occurred earlier than 2 weeks in this mouse DMM model. Gait disparity only occurred at later stage of OA in DMM mice. Notably, patella dislocation could occur in some of the DMM mice and cause a different pattern of OA in affected knee.
Microcomputed tomography (Micro-CT) has the potential to noninvasively image the structure of organs in rodent models with high spatial resolution and relatively short image acquisition times. However, motion artifacts associated with the normal respiratory motion of the animal may arise when imaging the abdomen or thorax. To reduce these artifacts and the accompanying loss of spatial resolution, we propose a prospective respiratory gating technique for use with anaesthetized, free-breathing rodents. A custom-made bed with an embedded pressure chamber was connected to a pressure transducer. Anaesthetized animals were placed in the prone position on the bed with their abdomens located over the chamber. During inspiration, the motion of the diaphragm caused an increase in the chamber pressure, which was converted into a voltage signal by the transducer. An output voltage was used to trigger image acquisition at any desired time point in the respiratory cycle. Digital radiographic images were acquired of anaesthetized, free-breathing rats with a digital radiographic system to correlate the respiratory wave form with respiration-induced organ motion. The respiratory wave form was monitored and recorded simultaneously with the x-ray radiation pulses, and an imaging window was defined, beginning at end expiration. Phantom experiments were performed to verify that the respiratory gating apparatus was triggering the micro-CT system. Attached to the distensible phantom were 100 microm diameter copper wires and the measured full width at half maximum was used to assess differences in image quality between respiratory-gated and ungated imaging protocols. This experiment allowed us to quantify the improvement in the spatial resolution, and the reduction of motion artifacts caused by moving structures, in the images resulting from respiratory-gated image acquisitions. The measured wire diameters were 0.135 mm for the stationary phantom image, 0.137 mm for the image gated at end deflation, 0.213 mm for the image gated at peak inflation, and 0.406 mm for the ungated image. Micro-CT images of anaesthetized, free-breathing rats were acquired with a General Electric Healthcare eXplore RS in vivo micro-CT system. Images of the thorax were acquired using the respiratory cycle-based trigger for the respiratory-gated mode. Respiratory gated-images were acquired at inspiration and end expiration, during a period of minimal respiration-induced organ motion. Gated images were acquired with a nominal isotropic voxel spacing of 44 microm in 20-25 min (80 kVp, 113 mAs, 300 ms imaging window per projection). The equivalent ungated acquisitions were 11 min in length. We observed improved definition of the diaphragm boundary and increased conspicuity of small structures within the lungs in the gated images, when compared to the ungated acquisitions. In this work, we have characterized the externally monitored respiratory wave form of free-breathing, anaesthetized rats and correlated the respiration-induced organ motion to the respiratory cycle...
Gas-liquid jets injected into fluidized beds of particles/catalyst find applications in many industrial processes. The effective distribution and mixing of the feed droplets with the entrained bed particles is vital in improving the process efficiency. The present study utilizes a sophisticated digital X-ray imaging system to study the internal flow structure of jets injected into fluidized beds. The system is equipped with an X-ray image intensifier (XRII) and optical detectors, which convert the transmitted X-ray photons into digital images of up to 60 frames s-1. The imaging technique provides useful information such as the jet expansion angle and the penetration distance. These are functional quantities in optimizing the performance of feed nozzles, and in modeling the jet-fluidized bed interactions.In this work, the horizontal injection of gas, gas-liquid, and liquid jets into fluidized beds is investigated. The results indicate that the jet expansion (half-angle) is considerably reduced for a gas-liquid jet (5-7 degrees) when compared to that of a gas jet (10-15 degrees). The gas-liquid jet also appears to penetrate more than a gas jet with the same momentum. When a liquid feed is introduced into a fluidized bed of particles, the particles may agglomerate if they are wet-enough to form liquid bridges. Improper feed distribution may be a direct contributor to enhanced agglomeration. In this regard, radio-opaque tracers mixed with the feed liquid are injected to track the formation and the movement of agglomerates. The tracer experiments show that the agglomerates are generated at the end of the jet region, close to its maximum penetration distance. A brief discussion on the modifications required to achieve improved contrast for the acquired images, and the effect of some important X-ray parameters are also included in the present study.
Predator loss and climate change are hallmarks of the Anthropocene yet their interactive effects are largely unknown. Here, we show that massive calcareous reefs, built slowly by the alga Clathromorphum nereostratum over centuries to millennia, are now declining because of the emerging interplay between these two processes. Such reefs, the structural base of Aleutian kelp forests, are rapidly eroding because of overgrazing by herbivores. Historical reconstructions and experiments reveal that overgrazing was initiated by the loss of sea otters, Enhydra lutris (which gave rise to herbivores capable of causing bioerosion), and then accelerated with ocean warming and acidification (which increased per capita lethal grazing by 34 to 60% compared with preindustrial times). Thus, keystone predators can mediate the ways in which climate effects emerge in nature and the pace with which they alter ecosystems.
Precise, noninvasive analysis and quantification of in vivo body composition is essential for research involving longitudinal, small-animal disease models. We investigated the feasibility and precision of a rapid, flat-panel μCT scanner to report whole body adipose tissue volume (ATV), lean tissue volume (LTV), skeletal tissue volume (STV), and bone mineral content (BMC) in 25 postmortem female and 52 live male Sprague-Dawley rats. μCT images, acquired in three 90-mm segments and reconstructed with 308 μm of isotropic voxel spacing, formed contiguous image volumes of each entire rat specimen. Three signal-intensity thresholds (determined to be -186, 5, and 155 HU) were used to classify each voxel as adipose, lean, or skeletal tissue, respectively. Tissue masses from the volume fractions of ATV, LTV, and STV were calculated from assumed tissue densities of 0.95, 1.05, and 1.92 g/cm(-3), respectively. A CT-derived total mass was calculated for each rat and compared with the gravimetrically measured mass, which differed on average for the postmortem female and the live male group by 2.5 and 1.1%, respectively. To evaluate the accuracy of the CT-derived body composition technique, following the live male study excised muscle tissue in the lower right leg of all rats in group B were compared with the image-derived LT measurement of the same regional compartment and found to differ on average by 2.2%. Through repeated CT measurements of postmortem specimens, the whole body ATV, LTV, STV, and BMC measurement analysis gave a precision value of ±0.6, 1.9, 1.7, and 0.5% of the average value, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.