Focused ultrasound (FUS) with microbubbles can temporally open the blood-brain barrier (BBB), and the cavitation activities of microbubbles play a key role in the BBB-opening process. Previous attempts used contrast-enhanced magnetic resonance imaging (CE-MRI) to correlate the mechanical index (MI) with the scale of BBB-opening, but MI only partially gauged acoustic activities, and CE-MRI did not fully explore correlations of pharmacodynamic/pharmacokinetic behaviors. Recently, the cavitation index (CI) has been derived to serve as an indicator of microbubble-ultrasound stable cavitation, and may also serve as a valid indicator to gauge the level of FUS-induced BBB opening. This study investigates the feasibility of gauging FUS-induced BBB opened level via the two indexes, MI and CI, through dynamic contrast-enhanced (DCE)-MRI analysis as well as passive cavitation detection (PCD) analysis. Pharmacodynamic/pharmacokinetic parameters derived from DCE-MRI were characterized to identify the scale of FUS-induced BBB opening. Our results demonstrated that DCE-MRI can successfully access pharmacodynamic/pharmacokinetic BBB-opened behavior, and was highly correlated both with MI and CI, implying the feasibility in using these two indices to gauge the scale of FUS-induced BBB opening. The proposed finding may facilitate the design toward using focused ultrasound as a safe and reliable noninvasive CNS drug delivery.
Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r (2) = 0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.
Background: Epilepsy is a neurological disorder characterized by abnormal neuron discharge, and onethird of epilepsy patients suffer from drug-resistant epilepsy (DRE). The current management for DRE includes epileptogenic lesion resection, disconnection, and neuromodulation. Neuromodulation is achieved through invasive electrical stimulus including deep brain stimulation, vagus nerve stimulation, or responsive neurostimulation (RNS). As an alternative therapy, transcranial focused ultrasound (FUS) can transcranially and non-invasively modulate neuron activity. Objective: This study seeks to verify the use of FUS pulsations to suppress spikes in an acute epileptic small-animal model, and to investigate possible biological mechanisms by which FUS pulsations interfere with epileptic neuronal activity. Methods: The study used a total of 76 Sprague-Dawley rats. For the epilepsy model, rats were administered pentylenetetrazol (PTZ) to induce acute epileptic-like abnormal neuron discharges, followed by FUS exposure. Various ultrasound parameters were set to test the epilepsy-suppressing effect, while concurrently monitoring and analyzing electroencephalogram (EEG) signals. Animal behavior was monitored and histological examinations were conducted to evaluate the hazard posed by ultrasound exposure and the expression of neuronal activity markers. Western blotting was used to evaluate the correlation between FUS-induced epileptic suppression and the PI3K-mTOR signaling pathway. Results: We observed that FUS pulsations effectively suppressed epileptic activity and observed EEG spectrum oscillations; the spike-suppressing effect depended on the selection of ultrasound parameters and highly correlated with FUS exposure level. Expression level changes of c-Fos and GAD65 were confirmed in the cortex and hippocampus, indicating that FUS pulsations deactivated excitatory cells and activated GABAergic terminals. No tissue damage, inflammatory response, or behavioral abnormalities were observed in rats treated with FUS under these exposure parameters. We also found that the FUS pulsations down-regulated the S6 phosphorylation and decreased pAKT expression. Conclusion: Our results suggest that pulsed FUS exposure effectively suppresses epileptic spikes in an acute epilepsy animal model, and finds that ultrasound pulsation interferes with neuronal activity and affects the PTZ-induced PI3K-Akt-mTOR pathway, which might help explain the mechanism underlying ultrasound-related epileptic spike control.
Focused ultrasound (FUS) with the presence of microbubbles induces blood brain barrier (BBB) opening in targeted areas and facilitates drug delivery. However, recent studies have indicated that FUS-BBB opening with excessive exposure levels may be associated with inflammatory response and cellular/tissue damage. Multiple weekly FUS exposures have been shown to be safe for human subjects. However the effect of more frequent FUS exposures is still unknown. This study examines whether frequent focused ultrasound blood brain barrier opening is associated with aggravated behavioral, histopathologic change or brain tissue damage. Two protocols of focused ultrasound blood brain barrier opening were devised using different microbubble doses (0.15 µl/kg and 0.4 µl/kg). Focused ultrasound exposure at a threshold level of BBB-opening, below-threshold level, or above level for intracerebral hemorrhage were delivered every 2 days. Animal behavioral and physiological changes were examined and recorded. Brain tissue was examined for hemorrhage and apoptosis. Results indicate that frequent exposure of excessive focused ultrasound (1.4 mechanical index) produced minor and short-term behavioral changes despite significant tissue damage, while frequent BBB opening with threshold or below-threshold FUS exposure (0.33–0.8 mechanical index) did not cause behavioral or histological change. Immunofluorescent examination of rat brain tissue indicated that excessive doses of microbubble administration induce an apparent cellular apoptotic response, which may be exacerbated by intracerebral hemorrhage. Experimental results suggest that frequent focused ultrasound blood brain barrier opening with sufficient ultrasound exposure level and a microbubble dose can be safe and pose minimal risk to brain tissue.
Ultrasound (US) has been found to rejuvenate and invigorate the hair follicles, increase the size of hair shafts, and promote new hair growth. Our present study found that dual-frequency US-mediated microbubble (MB) cavitation significantly enhanced minoxidil (Mx) delivery in both in vitro and in vivo models, while increasing the hair growth efficacy compared to single-frequency US sonication. the in vitro experiments showed that cavitation activity was enhanced more significantly during dual-frequency sonication than single-frequency sonication in higher concentration of MBs. The pigskin penetration depth in the group in which dual-frequency US was combined with MBs was 1.54 and 2.86 times greater than for single-frequency US combined with MBs and in the control group, respectively; the corresponding increases in the release rate of Mx at 18 hours in in vitro Franz-diffusioncell experiments were 24.9% and 43.7%. During 21 days of treatment in C57BL/6J mice experiments, the growth rate at day 11 in the group in which dual-frequency US was combined with MBs increased by 2.07 times compared to single-frequency US combined with MBs. These results indicate that dualfrequency US-mediated MB cavitation can significantly increase both skin permeability and transdermal drug delivery. At the same US power density, hair growth was greater in the group with dual-frequency US plus MBs than in the group with single-frequency US plus MBs, without damaging the skin in mice.
Combination therapy with focused ultrasound (FUS) and a neuroprotective agent, BNG-1, was examined in an acute carotid thrombotic occlusion model using LED irradiation in rat to improve the thrombolytic effect of rt-PA. Seven treatment groups included (A) intravenous bolus injection of 0.45 mg/kg rt-PA, (B) intravenous bolus injection of 0.9 mg/kg, (C) sonothrombolysis with FUS alone, (D) oral administration of 2 g/kg BNG-1 for 7 days alone, (E) A + D, (F) A + C, and (G) A + C + D. Four comparison groups were made including (H) 0.45 mg/kg rt-PA 20% bolus +80% IV fusion + FUS, (I) 0.9 mg/kg rt-PA with 10% bolus + 90% intravenous fusion, (J) B + C, (K) B + D. At 7 days after carotid occlusion, small-animal carotid ultrasound and 7 T MR angiography showed the recanalization rate of ≤50% stenosis was 50% in group B and 83% in group I, but 0% in groups A and C and 17% in group D. Combination therapy improved recanalization rate to 50–63% in groups E and F, to 67–83% in groups J and K, and to 100% in groups G and H. Our study demonstrated combination therapy with different remedies can be a feasible strategy to improve the thrombolytic effect of rt-PA.
Focused ultrasound phased array systems have attracted increased attention for brain therapy applications. However, such systems currently lack a direct and real-time method to intraoperatively monitor ultrasound pressure distribution for securing treatment. This study proposes a dual-mode ultrasound phased array system design to support transmit/receive operations for concurrent ultrasound exposure and backscattered focal beam reconstruction through a spherically focused ultrasound array. A 256-channel ultrasound transmission system was used to transmit focused ultrasonic energy (full 256 channels), with an extended implementation of multiple-channel receiving function (up to 64 channels) using the same 256-channel ultrasound array. A coherent backscatter-received beam formation algorithm was implemented to map the point spread function (PSF) and focal beam distribution under a free-field/transcranial environment setup, with the backscattering generated from a strong scatterer (a point reflector or a microbubble-perfused tube) or a weakly scattered tissue-mimicking graphite phantom. Our results showed that PSF and focal beam can be successfully reconstructed and visualized in free-field conditions and can also be transcranially reconstructed following skull-induced aberration correction. In vivo experiments were conducted to demonstrate its capability to preoperatively and semiquantitatively map a focal beam to guide blood-brain barrier opening. The proposed system may have potential for real-time guidance of ultrasound brain intervention, and may facilitate the design of a dual-mode ultrasound phased array for brain therapeutic applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.