A rapid, accurate and reliable reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of naproxen and its photodegradation products in methanol was developed and validated. An Inertsil 5-ODS-3V column (5 microm, C18, 250 x 4.6 mm i.d.) was used with a mobile phase of acetonitrile-methanol-1% HOAc in H2O (40:20:40, v/v/v). UV detection was set at 230 nm. The developed method satisfies system suitability criteria, peak integrity and resolution for the parent drug and its photoproducts. The intraday and interday standard deviations of five replicate determinations for five consecutive days at the working concentrations of 5.0, 10, 25, 50, and 100 microm were 0.23-0.98 with coefficients of variance (CVs) of between 0.96 and 4.56% for the former, and 0.14-1.15 with CVs of between 1.13 and 3.82% for the latter. The percentage recoveries were determined to be 98.34, 99.19, 100.18, 102.97 and 99.81%, respectively, at the five concentrations between 5.0 and 100 microm. The limit of quantitation of naproxen was determined to be 0.29 microg/mL, while the detection limit was 64 ng/mL. Four major photoproducts were observed from the HPLC chromatogram using a Panchum PR-2000 reactor which equipped with 8 W x 16 low-pressure quartz mercury lamps as the light source for irradiation of a naproxen sample in methanol. The structures of the photoproducts were confirmed by LC-ESI MS.
A high-performance liquid chromatographic (HPLC) assay method for assessing the degradation of tolmetin (TLM) is developed and validated under acidic, basic, and photoirradiated conditions. The HPLC method includes an Inertsil 5 ODS-3V column (250- x 4.6-mm i.d.), guard column of Inertsil 7 ODS-3V (50- x 4.6-mm i.d.), mobile phase of CH(3)OH-1% HOAc (64:36, v/v), and UV detection at 254 nm. The developed method satisfies the system suitability criteria, peak integrity, and resolution for the parent drug and its degradants. The established assay method exhibits good selectivity and specificity suitable for stability measurements. From the intra- and interday tests of six replicates, the coefficients of variation are between 0.20% and 1.77% for the former, and 0.12% and 3.40% for the latter. Recoveries are found to be 98.7-101.7%. TLM is determined to be more reactive when exposed to light and acidic conditions, yet TLM is stable in a basic medium. A kinetic study of the photodegradation of TLM shows that it follows an apparent first-order reaction in three alcoholic solvents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.