In this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system while providing low and stable pacing thresholds. (Funded by Medtronic; Micra Transcatheter Pacing Study ClinicalTrials.gov number, NCT02004873.).
Low-intensity anticoagulation with warfarin prevented cerebral infarction in patients with nonrheumatic atrial fibrillation without producing an excess risk of major hemorrhage. This benefit extended to patients over 70 years of age.
AimsAn estimated 10 000–15 000 pacemaker and implantable cardioverter–defibrillator (ICD) leads are extracted annually worldwide using specialized tools that disrupt encapsulating fibrous tissue. Additional information is needed regarding the safety of the devices that have been approved for lead extraction. The aim of this study was to determine whether complications due to device-assisted lead extraction might be more hazardous than published data suggest, and whether procedural safety precautions are effective.Methods and resultsWe searched the US Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database from 1995 to 2008 using the search terms ‘lead extraction and death’ and ‘lead extraction and injury’. Additional product specific searches were performed for the terms ‘death’ and ‘injury’. Between 1995 and 2008, 57 deaths and 48 serious cardiovascular injuries associated with device-assisted lead extraction were reported to the FDA. Owing to underreporting, the FDA database does not contain all adverse events that occurred during this period. Of the 105 events, 27 deaths and 13 injuries occurred in 2007–2008. During these 2 years, 23 deaths were linked with excimer laser or mechanical dilator sheath extractions. The majority of deaths and injuries involved ICD leads, and most were caused by lacerations of the right atrium, superior vena cava, or innominate vein. Overall, 62 patients underwent emergency surgical repair of myocardial perforations and venous lacerations and 35 (56%) survived.ConclusionThese findings suggest that device-assisted lead extraction is a high-risk procedure and that serious complications including death may not be mitigated by emergency surgery. However, skilled standby cardiothoracic surgery is essential when performing pacemaker and ICD lead extractions. Although the incidence of these complications is unknown, the results of our study imply that device-assisted lead extractions should be performed by highly qualified physicians and their teams in specialized centres.
Neurally mediated hypotension and bradycardia are believed to be common causes of syncope. We used the "upright-tilt test" (duration, less than or equal to 10 minutes) with or without an infusion of exogenous catecholamine (isoproterenol [1 to 5 micrograms per minute], given intravenously) to elicit bradycardia, hypotension, or both in 24 patients with recurrent syncope and in 18 control subjects. A conventional electrophysiologic test performed before the tilt test was positive in 9 of the 24 patients, revealing arrhythmias that may have caused recurrent syncope, but was negative and thus nondiagnostic in 15 patients. The tilt test alone (i.e., without isoproterenol) induced symptomatic bradycardia or hypotension in 1 of the 9 patients with positive electrophysiologic tests (11 percent), 4 of the 15 patients with negative electrophysiologic tests (27 percent), and none of the controls. When the isoproterenol infusion was administered during the tilt test, 9 of the 11 patients with negative electrophysiologic and tilt tests had syncope, marked slowing of the heart rate, and hypotension. In contrast, isoproterenol was associated with tachycardia and only a slight decline in arterial pressure in the 8 remaining patients with positive electrophysiologic tests and the 18 control subjects, and syncope developed in only 1 of the 8 patients with positive electrophysiologic tests and negative tilt tests (13 percent) and 2 of the 18 control subjects (11 percent). We conclude that an isoproterenol infusion administered in conjunction with the upright-tilt test may be useful for identifying susceptibility to neurally mediated recurrent syncope.
Background-Improvements in cardiac mapping are required to advance our understanding and treatment of arrhythmias.This study validated a new noncontact multielectrode array catheter and accompanying analysis system to provide electroanatomic mapping of the entire left ventricular (LV) endocardium during a single beat. Methods and Results-A 9F 64-electrode balloon array catheter with an inflated size of 1.8ϫ4.6 cm was used to simultaneously record electrical potentials generated by the heart and locate a standard electrophysiology (EP) catheter within the same chamber. By use of the recorded location of the EP-catheter tip, LV geometry was determined. Array potentials served as inputs to a high-order boundary-element method to produce 3360 potential points on the endocardial surface translatable into electrograms or color-coded activation maps. Three methods of validation were used: (1) driven electrodes in an in vitro tank were located; (2) waveforms generated from the array catheter were compared with catheter contact waveforms in canine LV; and (3)
Background-Endocardial mapping of sustained arrhythmias has traditionally been performed with a roving diagnostic catheter. Although this approach is adequate for many tachyarrhythmias, it has limitations. The purpose of this study was to evaluate a novel noncontact mapping system for assessing atrial tachyarrhythmias. Methods and Results-The mapping system consists of a 9F multielectrode-array balloon catheter that has 64 active electrodes and ring electrodes for emitting a locator signal. The locator signal was used to construct a 3-dimensional right atrial map; it was independently validated and was highly accurate. Virtual electrograms were calculated at 3360 endocardial sites in the right atrium. We evaluated right atrial activation by positioning the balloon catheter in the mid right atrium via a femoral venous approach. Experiments were performed on 12 normal mongrel dogs. The mean correlation coefficient between contact and virtual electrograms was 0.80Ϯ0.12 during sinus rhythm. Fifty episodes of atrial flutter induced in 11 animals were evaluated. In the majority of experiments, complete or almost complete reentrant circuits could be identified within the right atrium. Mean correlation coefficient between virtual and contact electrograms was 0.85Ϯ0.17 in atrial flutter. One hundred fifty-six episodes of pacing-induced atrial fibrillation were evaluated in 11 animals. Several distinct patterns of right atrial activation were seen, including single-activation wave fronts and multiple simultaneous-activation wave fronts. Mean correlation coefficient between virtual and contact electrograms during atrial fibrillation was 0.81Ϯ0.18. The accuracy of electrogram reconstruction was lower at sites Ͼ4.0 cm from the balloon center and at sites with a high spatial complexity of electrical activation. Conclusions-This novel noncontact mapping system can evaluate conduction patterns during sinus rhythm, demonstrate reentry during atrial flutter, and describe right atrial activation during atrial fibrillation. The accuracy of electrogram reconstruction was good at sites Ͻ4.0 cm from the balloon center, and thus the system has the ability to perform high-resolution multisite mapping of atrial tachyarrhythmias in vivo. (Circulation. 1999;99:1906-1913
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.