1999
DOI: 10.1161/01.cir.99.6.829
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a New Noncontact Catheter System for Electroanatomic Mapping of Left Ventricular Endocardium

Abstract: Background-Improvements in cardiac mapping are required to advance our understanding and treatment of arrhythmias.This study validated a new noncontact multielectrode array catheter and accompanying analysis system to provide electroanatomic mapping of the entire left ventricular (LV) endocardium during a single beat. Methods and Results-A 9F 64-electrode balloon array catheter with an inflated size of 1.8ϫ4.6 cm was used to simultaneously record electrical potentials generated by the heart and locate a standa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
117
2
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 148 publications
(120 citation statements)
references
References 12 publications
0
117
2
1
Order By: Relevance
“…Non-contact mapping systems utilize a multi-electrode array (MEA) catheter to simultaneously record endocardial activation over multiple areas [74]. The array is situated on a balloon with 64 electrodes allowing high-density mapping from a single heartbeat.…”
Section: Tissue Characterizationmentioning
confidence: 99%
“…Non-contact mapping systems utilize a multi-electrode array (MEA) catheter to simultaneously record endocardial activation over multiple areas [74]. The array is situated on a balloon with 64 electrodes allowing high-density mapping from a single heartbeat.…”
Section: Tissue Characterizationmentioning
confidence: 99%
“…Simultaneous unipolar AEGs can be collected using high-density NCM [17]. DF analysis of such simultaneous unipolar atrial signals during persAF could help to reveal the spatiotemporal distribution of the atrial activations.…”
Section: Clinical Significancementioning
confidence: 99%
“…Additionally, proper atrial phase mapping can only be achieved with simultaneous atrial recordings [11]. Currently, multi-electrode array (MEA) and baskets provide simultaneous global unipolar AEG measurements [17]. However, there are no commercial solutions for online DF analyses for simultaneous unipolar AEGs.…”
Section: Introductionmentioning
confidence: 99%
“…10,11,14 The system consists of a 64-multielectrode array (MEA) mounted on a 7.5-mL inflatable balloon on a 9F catheter, an amplifier system, and a Silicon Graphics Workstation. For left ventricular study, the MEA was introduced under fluoroscopic guidance from the left femoral artery via the retrograde transaortic route into the ventricle.…”
Section: Noncontact Mappingmentioning
confidence: 99%
“…Previous validation studies were confined to assessment of intracardiac activation, 10,11 and therefore, NCM has not yet been validated as a clinical tool to characterize repolarization changes. In the present study, we compared repolarization timings measured by reconstructed UEs with MAP recordings recorded simultaneously at the same sites in the human left or right ventricle.…”
mentioning
confidence: 99%