Hemiarthroplasty is a common treatment for femoral neck fractures in the elderly population. The main complications are periprosthetic dislocation and infection, which potentially impact morbidity and quality of life and may contribute to mortality. This procedure can be technically demanding, and adequate closure of the capsule and soft tissue cannot be emphasized enough. One advantage of a bipolar prosthesis is that it can be easily converted to a total hip arthroplasty without replacing the femoral component and with approximately the same complication rates as a revision total hip arthroplasty. Cement should be used when the patient is osteoporotic or has a Dorr type-C canal because there is a significant reduction in risk of fracture. The addition of a collared stem is helpful if there is a crack in the calcar extending from the fracture. The procedure is as follows. (1) The patient is placed in the lateral decubitus position. (2) The surgical site is prepared and draped to above the iliac crest and mid-sacrum. (3) A posterior approach is utilized. (4) The hip is dislocated. (5) A cut is made at the femoral neck. (6) The implant is templated with the femoral head. (7) The femur is broached. (8) The trial implant is placed. (9) The femur is cemented. (10) Trial implants are removed and cement is placed. (11) The final stem implant is placed in 5° to 10° of anteversion. (12) The final head and neck implants are trialed and then placed. (13) Implant position and range of motion are tested. (14) The surgical wound is irrigated. (15) Short external rotators are repaired. The posterior approach, which is often used, is known for increased rates of dislocation. The rate of dislocation can be minimized with repair of the posterior capsule and posterior soft tissue. Proper placement of the implants is of the utmost importance to minimize complications. Other contributing factors that lead to dislocation are implant malpositioning and patient factors.
Infection following open fracture is a significant source of morbidity and mortality. Therefore, a central tenet of treatment is to minimize the risk of infection. The initial risk of infection is determined by wound characteristics, such as size, soft tissue coverage, vascular injury, and contamination. While no consensus exists on optimal antibiotic regimen, early administration of prophylactic antibiotics, within an hour of injury, when possible, has been shown definitively to decrease the risk of infection. Infection risk is further reduced by early irrigation with normal saline and aggressive debridement of devitalized tissue. Patient factors that increase risk of infection following open fracture include diabetes mellitus, smoking, male gender, and lower extremity fracture.
Disclosure: The authors indicated that no external funding was received for any aspect of this work. The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSEST/A223).
Disclosure: The authors indicated that no external funding was received for any aspect of this work. The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSEST/A225).
Objective: We present a technical trick for surgical treatment of with (Schatzker IV) medial tibial plateau fractures treated with a standardized operative protocol with early radiographic and clinical outcomes.Methods: Skeletally mature patients with a medial tibial plateau fracture (Schatzker IV) admitted to an academic level 1 trauma center between 2002 and 2017 were identified by institutional database review. Screening of operative reports selected patients treated with a single anteromedial approach following a standard surgical protocol by a single surgeon. Data relevant to initial injury characteristics, patient comorbidities, operative management, and follow-up were extracted by chart review. Preoperative and postoperative clinical documentation and radiographs were examined to measure specific injury and outcome variables. Radiographic and clinical outcomes were validated by one fellowship-trained orthopedic trauma surgeon and 2 orthopedic trauma fellows.Results: Review of 335 patients with tibial plateau fractures during the study period identified a series of 17 high-energy, medial partial articular fractures that met the inclusion criteria. Injury pattern included articular depression in all patients, meniscal injury in 59%, ligamentous injury in 65% and none had compartment syndrome. Immediate radiographic analysis showed restoration of the articular surface, condylar width, and mechanical alignment for all patients. No patient experienced wound healing complications, soft tissue infection or skin necrosis. Median time to radiographic fracture consolidation was 12.9 weeks and ambulation without achieved at 18.9 weeks. Conclusions:The use of a standard anteromedial approach to the knee via medial parapatellar arthrotomy with full-thickness medial skin flap for isolated high-energy medial column tibial plateau fractures offers improved visualization and facilitates reduction and fixation of the lateral and anterior articular impaction while enabling immediate repair or reconstruction of associated meniscal and ligamentous (anterior cruciate ligament, posterior cruciate ligament, medial collateral ligament) pathology. Short-term and mid-term follow-up demonstrates good clinical and radiographic patient outcomes. This approach is a safe and reliable option for treatment of this unique and challenging injury pattern.
Objective: Collection of bone graft with the Reamer-Irrigator-Aspirator (RIA) system has become common practice across the field of orthopaedic surgery. While RIA bone graft is typically obtained from native long bones, grafting material can likewise be harvested from long bones that have previously undergone the placement and removal of an intramedullary nail, a process termed rereamed RIA (RRR). The purpose of this study was to evaluate the total protein and growth factor concentrations present in native-RIA (NR) compared with RRR samples.Methods: NR and RRR bone grafts were collected intraoperatively with the RIA system and processed to evaluate both the aqueous and the hard tissue components. Total protein concentration and specific growth factors were analyzed using standard bicinchoninic acid and multiplex assays, respectively. Analyte levels were then normalized to the total amount of protein detected.Results: Total protein levels were comparable between NR and RRR samples for both the aqueous filtrate and the hard tissue samples. When normalized, while levels of bone morphogenic protein-2 and vascular endothelial growth factor were comparable in the hard tissue component, the aqueous filtrate from the RRR sample was found to have elevated levels of growth factors, with bone morphogenic protein-2 reaching statistical significance.Conclusions: This study demonstrates that ample protein is found within both NR and RRR samples, with comparable or elevated levels of osteogenic growth factors found within RRR samples. Future, larger, prospective studies will be required to evaluate the osteogenic potential and clinical efficacy of NR and RRR cancellous bone grafts to validate their equivalency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.