The aim of the present study was to evaluate the bond strength (BS) of root canal fillings to root dentin using the reciprocating file-matched single-cone or lateral compaction techniques with resin-based and calcium-silicate-based sealers. Maxillary canine roots were prepared and filled using one of the following approaches: Reciproc R40 file and R40 single cone, WaveOne Large file and Large single cone, or ProTaper up to F4 file with lateral compaction. The root filling was performed using AH Plus, Epiphany SE or MTA Fillapex (n = 10). Three 1-mm-thick slices were obtained from each third of each root. Two slices were subjected to a push-out test, and the other slices were prepared for scanning electron microscopy (SEM) to examine the dentin-sealer interface. Data (in MPa) from the push-out tests were analyzed using a two-way ANOVA and Tukey's test (p < 0.05). Failure modes (adhesive, cohesive or mixed) were evaluated at ×25 magnification. The single-cone techniques resulted in lower BS values than the lateral compaction technique. For lateral compaction, AH Plus and Epiphany SE showed the highest and lowest BS values, respectively. Slight differences were observed between sealers when the single-cone techniques were used. A tendency to reduce the BS toward the apical third was observed. Adhesive failures were predominant for all experimental conditions. A closer adaption of the filling material on the root dentin was observed for the AH Plus and lateral compaction techniques. The Reciproc and WaveOne techniques were associated with lower BS values than the lateral compaction technique. However, the effect of the root canal filling technique appears to be sealer-dependent.
The aim of this study was to evaluate the influence of drying protocols (DP) on the apical sealing (AS) and on the bond strength (BS) of teeth filled with different sealers. The root canals of one hundred and fifty-six roots of maxillary canines were prepared with Reciproc rotary files (R50). The teeth were randomly divided into four groups (n = 39), according to the DP: GI-paper points; GII-70% isopropyl alcohol + aspiration with NaviTip points; GIII-95% ethanol + paper points; GIV-EndoVac + paper points. Each group was divided into subgroups, according to the sealer used: AH Plus, Sealapex and MTA Fillapex, using a single-cone technique. Evaluation of AS and BS was performed with fluid filtration (FF) and push-out (PO) methods, respectively. The PO test consisted of sectioning the roots, and subjecting a single slice from each third to testing and analysis for failure type. The data was submitted to two-way and three-way variance analysis (ANOVA) and Tukey (α = 5%). The AS showed no drying protocol influence. The FF results revealed a statistically significant difference between MTA and Sealapex (p < 0.05) sealers. The BS test values showed that there was no statistical significant difference among the canal thirds (p > 0.05), but that there was such a difference among the sealers (p < 0.05), among the protocols (p < 0.05), and in the interaction between sealers and protocols (p < 0.05). AH Plus revealed the highest BS values among the sealers; the highest BS results for the sealers occurred with the specimens used with isopropyl alcohol, compared with ethanol and EndoVac.
Direitos para esta edição cedidos à Atena Editora pelos autores. Todo o conteúdo deste livro está licenciado sob uma Licença de Atribuição Creative Commons. Atribuição-Não-Comercial-NãoDerivativos 4.0 Internacional (CC BY-NC-ND 4.0).O conteúdo dos artigos e seus dados em sua forma, correção e confiabilidade são de responsabilidade exclusiva dos autores, inclusive não representam necessariamente a posição oficial da Atena Editora. Permitido o download da obra e o compartilhamento desde que sejam atribuídos créditos aos autores, mas sem a possibilidade de alterá-la de nenhuma forma ou utilizá-la para fins comerciais. Todos os manuscritos foram previamente submetidos à avaliação cega pelos pares, membros do Conselho Editorial desta Editora, tendo sido aprovados para a publicação com base em critérios de neutralidade e imparcialidade acadêmica.A Atena Editora é comprometida em garantir a integridade editorial em todas as etapas do processo de publicação, evitando plágio, dados ou resultados fraudulentos e impedindo que interesses financeiros comprometam os padrões éticos da publicação. Situações suspeitas de má conduta científica serão investigadas sob o mais alto padrão de rigor acadêmico e ético.
CAMILO, C. C. A. Evaluation of single-cone obturation techniques of reciprocating systems with different sealers related to the apical sealing and bond strength to dentin. 2014. 82 p. Tese
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.