Mass spectrometry-based screening can be applied to a wide range of targets, including those intractable targets that use substrates such as lipids, fatty acids, phospholipids, steroids, prostaglandins, and other compounds not generally amenable to conventional screening techniques. The major limitation to this approach is throughput, making HTS via mass spectrometry impractical. We present a mass spectrometry-based technique and hardware for lead discovery applications. Mass spectrometry enables the design of label-free assays using biologically native substrates for a wide range of enzymatic targets. This system can be used for the direct quantification of analytes in complex reaction mixtures with typical throughputs of 4-5 s per sample. A mass spectrometry-based assay was developed to identify inhibitors of acetylcholinesterase, an enzyme with clinical importance in Alzheimer's disease. The system was used to screen a small chemical library. Several potent inhibitors were identified, and the IC(50) values of the inhibitors were determined.
Small molecule high-throughput screening in drug discovery today is dominated by techniques which are dependent upon artificial labels or reporter systems. While effective, these approaches can be affected by certain experimental limitations, such as conformational restrictions imposed by the selected label or compound fluorescence/quenching. Label-free approaches potentially address many of these issues by allowing researchers to investigate more native systems without fluorescence- or luminescence-based readouts. However, due to throughput and expense constraints, label-free methods have been largely relegated to a supporting role as the basis of secondary assays. In this review, we describe recent improvements in impedance-based, optical biosensor-based, automated patch clamp and mass spectrometry technologies that have enhanced their ease of use and throughput and, hence, their utility for primary screening of small- to medium-sized compound libraries. The ultimate maturation of these techniques will enable drug discovery researchers to screen large chemical libraries against minimally manipulated biological systems.
Label-free in vitro potency assays are an emerging field in drug discovery to enable more physiological conditions, to improve the readout quality, and to save time. For this approach mass spectrometry (MS) is a powerful technology to directly follow physiological processes. The speed of this methodology, however, was for a long time not compatible with chemiluminescence- or fluorescence-based assays. Recent advances in matrix-assisted laser desorption/ionization (MALDI) instrumentation paved the way for high-throughput MS analysis of label-free assays for large compound libraries, whereas electrospray ionization (ESI)-based mass spectrometers equipped with RapidFire autosamplers were limited to medium throughput. Here we present a technological advancement of the RapidFire device to enable cycle times of 2.5 s per sample. This newly developed BLAZE-mode substantially boosted the ESI-MS analysis speed, providing an alternative technology for label-free high-throughput screening.
Mass spectrometry is an emerging format for label-free high-throughput screening. The main limitation of mass spectrometry is throughput, due to the requirement to purify samples prior to ionization. Here the authors compare an automated high-throughput mass spectrometry (HTMS) system (RapidFire) with the scintillation proximity assay (SPA). The cancer therapy target AKT1/PKBalpha was screened against a focused library of kinase inhibitors and IC50 values determined for all compounds that exhibit > 50% inhibition. A selection of additional compounds that exhibited
Mass spectrometry-based screening can be applied to a wide range of targets, including those intractable targets that use substrates such as lipids, fatty acids, phospholipids, steroids, prostaglandins, and other compounds not generally amenable to conventional screening techniques. The major limitation to this approach is throughput, making HTS via mass spectrometry impractical. We present a mass spectrometry-based technique and hardware for lead discovery applications. Mass spectrometry enables the design of label-free assays using biologically native substrates for a wide range of enzymatic targets. This system can be used for the direct quantification of analytes in complex reaction mixtures with typical throughputs of 4-5 s per sample. A mass spectrometry-based assay was developed to identify inhibitors of acetylcholinesterase, an enzyme with clinical importance in Alzheimer's disease. The system was used to screen a small chemical library. Several potent inhibitors were identified, and the IC(50) values of the inhibitors were determined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.