A new formulation of volatile nanodroplets stabilized by a protein and polymer coating and loaded with magnetic nanoparticles is developed. The droplets show enhanced stability and phase conversion efficiency upon ultrasound exposure compared with existing formulations. Magnetic targeting, encapsulation, and release of an anticancer drug are demonstrated in vitro with a 40% improvement in cytotoxicity compared with free drug.
Oncolytic viruses (OV) could become the most powerful and selective cancer therapies. However, the limited transport of OV into and throughout tumors following intravenous injection means their clinical administration is often restricted to direct intratumoral dosing. Application of physical stimuli, such as focused ultrasound, offers a means of achieving enhanced mass transport. In particular, shockwaves and microstreaming resulting from the instigation of an ultrasound-induced event known as inertial cavitation can propel OV hundreds of microns. We have recently developed a polymeric cup formulation which, when delivered intravenously, provides the nuclei for instigation of sustained inertial cavitation events within tumors. Here we report that exposure of tumors to focused ultrasound after intravenous coinjection of cups and oncolytic vaccinia virus , leads to substantial and significant increases in activity. When cavitation was instigated within SKOV-3 or HepG2 xenografts, reporter gene expression from vaccinia virus was enhanced 1,000-fold (P < 0.0001) or 10,000-fold (P < 0.001), respectively. Similar increases in the number of vaccinia virus genomes recovered from tumors were also observed. In survival studies, the application of cup mediated cavitation to a vaccinia virus expressing a prodrug converting enzyme provided significant (P < 0.05) retardation of tumor growth. This technology could improve the clinical utility of all biological therapeutics including OV.
In the present proof of principle study, we evaluated the homogenous angular spectrum method for passive acoustic mapping (AS-PAM) of microbubble oscillations using simulated and experimental data. In the simulated data we assessed the ability of AS-PAM to form 3D maps of a single and multiple point sources. Then, in the two dimensional limit, we compared the 2D maps from AS-PAM with alternative frequency and time domain passive acoustic mapping (FD- and TD-PAM) approaches. Finally, we assessed the ability of AS-PAM to visualize microbubble activity in vivo with data obtained during 8 different experiments of FUS-induced blood-brain barrier disruption in 3 nonhuman primates, using a clinical MR-guided FUS system. Our in silico results demonstrate AS-PAM can be used to perform 3D passive acoustic mapping. 2D AS-PAM as compared to FD- PAM and TD-PAM is 10 and 200 times faster respectively and has similar sensitivity, resolution, and localization accuracy, even when the noise was 10-fold higher than the signal. In-vivo, the AS-PAM reconstructions of emissions at frequency bands pertinent to the different types of microbubble oscillations were also found to be more sensitive than TD-PAM. AS-PAM of harmonic-only components predicted safe blood-brain barrier disruption, whereas AS-PAM of broadband emissions correctly identified MR-evident tissue damage. The disparity (3.2mm) in the location of the cavitation activity between the three methods was within their resolution limits. These data clearly demonstrate that AS-PAM is a sensitive and fast approach for PAM, thus providing a clinically relevant method to guide therapeutic ultrasound procedures.
Microbubble enhancement of thrombolysis is supported by a broad range of in vitro and in vivo evidence that demonstrates improved lysis compared to conventional drug treatment or ultrasound without microbubbles. Clinically, this is shown by accelerated recanalisation of occluded arteries; however, further research is needed to ensure patient safety. Before such techniques can enter widespread clinical practice, an improved understanding of the role of microbubbles in sonothrombolysis is required, in addition to demonstration of significant improvement over existing treatments and the development of reliable real-time monitoring protocols.
Small interfering RNA (siRNA) has significant therapeutic potential but its clinical translation has been severely inhibited by a lack of effective delivery strategies. Previous work has demonstrated that perfluorocarbon nanodroplets loaded with magnetic nanoparticles can facilitate the intracellular delivery of a conventional chemotherapeutic drug. The aim of this study is to determine whether a similar agent can provide a means of delivering siRNA, enabling efficient transfection without degradation of the molecule. Chitosandeoxycholic acid nanoparticles containing perfluoropentane and iron oxide (d 0 = 7.5 ± 0.35 nm) with a mean hydrodynamic diameter of 257.6 ± 10.9 nm are produced. siRNA (AllStars Hs cell death siRNA) is electrostatically bound to the particle surface and delivery to lung cancer cells and breast cancer cells is investigated with and without ultrasound exposure (500 kHz, 1 MPa peakto-peak focal pressure, 40 cycles per burst, 1 kHz pulse repetition frequency, 10 s duration). The results show that siRNA functionality is not impaired by the treatment protocol and that the nanodroplets are able to successfully promote siRNA uptake, leading to significant apoptosis (52.4%) 72 h after ultrasound treatment.
Magnetic targeting of microbubbles functionalized with superparamagnetic nanoparticles has been demonstrated previously for diagnostic (B-mode) ultrasound imaging and shown to enhance gene delivery in vitro and in vivo. In the present work, passive acoustic mapping (PAM) was used to investigate the potential of magnetic microbubbles for localizing and enhancing cavitation activity under focused ultrasound. Suspensions of magnetic microbubbles consisting of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), air and 10 nm diameter iron oxide nanoparticles were injected into a tissue mimicking phantom at different flow velocities (from 0 to 50 mm s(-1)) with or without an applied magnetic field. Microbubbles were excited using a 500 kHz single element focused transducer at peak negative focal pressures of 0.1-1.0 MPa, while a 64 channel imaging array passively recorded their acoustic emissions. Magnetic localization of microbubble-induced cavitation activity was successfully achieved and could be resolved using PAM as a shift in the spatial distribution and increases in the intensity and sustainability of cavitation activity under the influence of a magnetic field. Under flow conditions at shear rates of up to 100 s(-1) targeting efficacy was maintained. Application of a magnetic field was shown to consistently increase the energy of cavitation emissions by a factor of 2-5 times over the duration of exposures compared to the case without targeting, which was approximately equivalent to doubling the injected microbubble dose. These results suggest that magnetic targeting could be used to localize and increase the concentration of microbubbles and hence cavitation activity for a given systemic dose of microbubbles or ultrasound intensity.
Ultrasound (US), in combination with microbubbles, has been found to be a potential alternative to viral therapies for transfecting biological cells. The translation of this technique to the clinical environment, however, requires robust and systematic optimization of the acoustic parameters needed to achieve a desired therapeutic effect. Currently, a variety of different devices have been developed to transfect cells in vitro, resulting in a lack of standardized experimental conditions and difficulty in comparing results from different laboratories. To overcome this limitation, we propose an easy-to-fabricate and cost-effective device for application in US-mediated delivery of therapeutic compounds. It comprises a commercially available cell culture dish coupled with a silicon-based "lid" developed in-house that enables the device to be immersed in a water bath for US exposure. Described here are the design of the device, characterization of the sound field and fluid dynamics inside the chamber and an example protocol for a therapeutic delivery experiment.
Microbubbles are currently in clinical use as ultrasound contrast agents and under active investigation as mediators of ultrasound therapy. To improve the theranostic potential of microbubbles, nanoparticles can be attached to the bubble shell for imaging, targeting and/or enhancement of acoustic response. Existing methods for fabricating particle-loaded bubbles, however, require the use of polymers, oil layers or chemical reactions for particle incorporation; embed/attach the particles that can reduce echogenicity; impair biocompatibility; and/or involve multiple processing steps. Here, we describe a simple method to embed nanoparticles in a phospholipid-coated microbubble formulation that overcomes these limitations. Magnetic nanoparticles are used to demonstrate the method with a range of different microbubble formulations. The size distribution and yield of microbubbles are shown to be unaffected by the addition of the particles. We further show that the microbubbles can be retained against flow using a permanent magnet, can be visualised by both ultrasound and magnetic resonance imaging (MRI) and can be used to transfect SH-SY5Y cells with fluorescent small interfering RNA under the application of a magnetic field and ultrasound field.Electronic supplementary materialThe online version of this article (doi:10.1007/s13346-017-0366-7) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.