Purpose Magnetic activated cell sorting (MACS) eliminates apoptotic spermatozoa based on the presence of externalized phosphatidylserine residues. We evaluated the outcome of male fertility treatment when intracytoplasmic sperm injection (ICSI) into human oocytes was performed with non-apoptotic MACS-selected spermatozoa. Methods 196 couples were treated by ICSI following spermatozoa preparation by MACS (study group; 122 couples) or density gradient centrifugation (DGC) (control group; 74 couples). Fertilization, cleavage, pregnancy, and implantation rates were analyzed. Results The percentage of sperm with normal morphology after MACS selection was improved. Cleavage and pregnancy rates were higher, respectively, in the study group than in control. A slightly higher implantation rate was also observed in the study group. Conclusions MACS selection of human spermatozoa increased cleavage and pregnancy rates in oligoasthenozoospermic ART cases. This novel method for selecting nonapoptotic spermatozoa for ICSI is safe and reliable, and may improve the assisted reproduction outcome.
Reproductive health of humans and animals exposed to daily irradiants from solar/cosmic particles remains largely understudied. We evaluated the sensitivities of bovine and mouse oocytes to bombardment by krypton-78 (1 Gy) or ultraviolet B (UV-B; 100 microjoules). Mouse oocytes responded to irradiation by undergoing massive activation of caspases, rapid loss of energy without cytochrome-c release, and subsequent necrotic death. In contrast, bovine oocytes became positive for annexin-V, exhibited cytochrome-c release, and displayed mild activation of caspases and downstream DNAses but with the absence of a complete cell death program; therefore, cytoplasmic fragmentation was never observed. However, massive cytoplasmic fragmentation and increased DNA damage were induced experimentally by both inhibiting RAD51 and increasing caspase 3 activity before irradiation. Microinjection of recombinant human RAD51 prior to irradiation markedly decreased both cytoplasmic fragmentation and DNA damage in both bovine and mouse oocytes. RAD51 response to damaged DNA occurred faster in bovine oocytes than in mouse oocytes. Therefore, we conclude that upon exposure to irradiation, bovine oocytes create a physiologically indeterminate state of partial cell death, attributed to rapid induction of DNA repair and low activation of caspases. The persistence of these damaged cells may represent an adaptive mechanism with potential implications for livestock productivity and long-term health risks associated with human activity in space.
Immature dendritic cells (IDc), ‘dexosomes’, are promising natural nanomaterials for cancer diagnose and therapy. Dexosomes were isolated purely from small-scale-up production by using t25-cell-culture flasks. Total RNA was measured as 1.43 ± 0.33 ng/106 cell. Despite the fact that they possessed a surface that is highly abundant in protein, this did not become a significant effect on the DOX loading amount. Ultrasonication was used for doxorubicin (DOX) loading into the IDc dexosomes. In accordance with the literature, three candidate DOX formulations were designed as IC50 values; dExoIII, 1.8 µg/mL, dExoII, 1.2 µg/mL, and dExoI, 0.6 µg/mL, respectively. Formulations were evaluated by MTT test against highly metastatic A549 (CCL-185; ATTC) cell line. Confocal images of unloaded (naïve) were obtained by CellMaskTM membrane staining before DOX loading. Although, dexosome membranes were highly durable subsequent to ultrasonication, it was observed that dexosomes could not be stable above 70 °C during the SEM-image analyses. dExoIII displayed sustained release profile. It was found that dynamic light scattering (DLS) and nanoparticle tracking analysis (NTA) results were in good agreement with each other. Zeta potentials of loaded dexosomes have approximately between −15 to −20 mV; and, their sizes are 150 nm even after ultrasonication. IDcJAWSII dexosomes can be able to be utilized as the “BioNanoMaterial” after DOX loading via ultrasonication technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.