We have developed a pixellated high energy X-ray detector instrument to be used in a variety of imaging applications. The instrument consists of either a Cadmium Zinc Telluride or Cadmium Telluride (Cd(Zn)Te) detector bump-bonded to a large area ASIC and packaged with a high performance data acquisition system. The 80 by 80 pixels each of 250 μm by 250 μm give better than 1 keV FWHM energy resolution at 59.5 keV and 1.5 keV FWHM at 141 keV, at the same time providing a high speed imaging performance. This system uses a relatively simple wire-bonded interconnection scheme but this is being upgraded to allow multiple modules to be used with very small dead space. The readout system and the novel interconnect technology is described and how the system is performing in several target applications.
We present the results from a feasibility study which measures properties in the terahertz frequency range of excised cancerous, dysplastic and healthy colonic tissues from 30 patients. We compare their absorption and refractive index spectra to identify trends which may enable different tissue types to be distinguished. In addition, we present statistical models based on variations between up to 17 parameters calculated from the reflected time and frequency domain signals of all the measured tissues. These models produce a sensitivity of 82% and a specificity of 77% in distinguishing between healthy and all diseased tissues and a sensitivity of 89% and a specificity of 71% in distinguishing between dysplastic and healthy tissues. The contrast between the tissue types was supported by histological staining studies which showed an increased vascularity in regions of increased terahertz absorption.
Functional cranial near-infrared spectroscopy (NIRS) has been widely used to investigate the haemodynamic changes which occur in response to functional activation. The technique exploits the different absorption spectra of oxy- and deoxy-haemoglobin ([HbO2] [HHb]) in the near-infrared region to measure the changes in oxygenation and haemodynamics in the cortical tissue. The aim of this study was to use an optical topography system to produce topographic maps of the haemodynamic response of both frontal cortex (FC) and motor cortex (MC) during anagram solving while simultaneously monitoring the systemic physiology (mean blood pressure, heart rate, scalp flux). A total of 22 young healthy adults were studied. The activation paradigm comprised of 4-, 6- and 8- letter anagrams. 12 channels of the optical topography system were positioned over the FC and 12 channels over the MC. During the task 12 subjects demonstrated a significant change in at least one systemic variable (p < or = 0.05). Statistical analysis of task-related changes in [HbO2] and [HHb], based on a Student's t-test was insufficient to distinguish between cortical haemodynamic activation and systemic interference. This lead to false positive haemodynamic maps of activation. It is therefore necessary to use statistical testing that incorporates the systemic changes that occur during brain activation.
The use of THz radiation as a potential tool for medical imaging is of increasing interest. In this paper three methods of analysis of THz spectroscopic information for diagnosis of tissue pathologies at THz frequencies are presented. The frequency-dependent absorption coefficients, refractive indices and Debye relaxation times of pure water and pure lipids were measured and used as prior knowledge in the different theoretical methods for the determination of concentration. Three concentration analysis methods were investigated: (a) linear spectral decomposition, (b) spectrally averaged dielectric coefficient method and (c) the Debye relaxation coefficient method. These methods were validated on water and lipid emulsions by determining the concentrations of phantom chromophores and comparing to the known composition. The accuracy and resolution of each method were determined to assess the potential of each method as a tool for medical diagnosis at THz frequencies.
SummaryDue to its low beam current and charge compensation mechanism He-Ion scanning microscopy is a very promising tool for imaging biological cells. However, to obtain relevant information, the method used for sample preparation is also critical. In this work, we have used a Carl Zeiss Orion Plus helium-ion microscope to study the effect of sample gold coating on the morphology of human colorectal adenocarcinoma Caco2 cells. The fixative glutaraldehyde was used and the selective gold coating of the samples was investigated. A comparative study with standard scanning electron microscopy is presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.