This study showed acceptable dimensional inter-arterial correlations between 3D printed models, 3D virtual models and authentic soft tissue anatomy of the central mesenteric vessels, and weaker inter-venous correlations between all the models, reflecting the highly variable nature of veins in situ.
Background
The impact of the position of the middle colic artery (MCA) bifurcation and the trajectory of the accessory MCA (aMCA) on adequate lymphadenectomy when operating colon cancer have as of yet not been described and/or analysed in the literature. The aim of this study was to determine the MCA bifurcation position to anatomical landmarks and to assess the trajectory of aMCA.
Methods
The colonic vascular anatomy was manually reconstructed in 3D from high-resolution CT datasets using Osirix MD and 3-matic Medical and analysed. CT datasets were exported as STL files and supplemented with 3D printed models when required.
Results
Thirty-two datasets were analysed. The MCA bifurcation was left to the superior mesenteric vein (SMV) in 4 (12.1%), in front of SMV in 17 (53.1%) and right to SMV in 11 (34.4%) models. Median distances from the MCA origin to bifurcation were 3.21 (1.18–15.60) cm. A longer MCA bifurcated over or right to SMV, while a shorter bifurcated left to SMV (r = 0.457, p = 0.009). The main MCA direction was towards right in 19 (59.4%) models. When initial directions included left, the bifurcation occurred left to or anterior to SMV in all models. When the initial directions included right, the bifurcation occurred anterior or right to SMV in all models. The aMCA was found in 10 (31.3%) models, following the inferior mesenteric vein (IMV) in 5 near the lower pancreatic border. The IMV confluence was into SMV in 18 (56.3%), splenic vein in 11 (34.4%) and jejunal vein in 3 (9.4%) models.
Conclusion
Awareness of the wide range of MCA bifurcation positions reported is crucial for the quality of lymphadenectomy performed. The aMCA occurs in 31.3% models and its trajectory is in proximity to the lower pancreatic border in one half of models, indicating that it needs to be considered when operating splenic flexure cancer.
Background
The splenic flexure is irrigated from two vascular areas, both from the middle colic and the left colic artery. The challenge for the surgeon is to connect these two vascular areas in an oncological safe procedure.
Materials and methods
The vascular anatomy, manually 3D reconstructed from 32 preoperative high-resolution CT datasets using Osirix MD, Mimics Medical and 3-matic Medical Datasets, were exported as STL-files, video clips, stills and supplemented with 3D printed models.
Results
Our first major finding was the difference in level between the middle colic and the inferior mesenteric artery origins. We have named this relationship a mesenteric inter-arterial stair. The middle colic artery origin could be found cranial (median 3.38 cm) or caudal (median 0.58 cm) to the inferior mesenteric artery. The lateral distance between the two origins was 2.63 cm (median), and the straight distance 4.23 cm (median). The second finding was the different trajectories and confluence pattern of the inferior mesenteric vein. This vein ended in the superior mesenteric/jejunal vein (21 patients) or in the splenic vein (11 patients). The inferior mesenteric vein confluence could be infrapancreatic (17 patients), infrapancreatic with retropancreatic arch (7 patients) or retropancreatic (8 patients). Lastly, the accessory middle colic artery was present in ten patients presenting another pathway for lymphatic dissemination.
Conclusion
The IMV trajectory when accessible, is the solution to the mesenteric inter-arterial stair. The surgeon could safely follow the IMV to its confluence. When the IMV trajectory is not accessible, the surgeon could follow the caudal border of the pancreas.
Graphical abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.