BACKGROUND:Measurement of serum androgens is important in adult, geriatric, pediatric endocrinology, and oncology patients. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for simultaneous measurement of androstenedione, dehydroepiandrosterone (DHEA), and testosterone in these patients.
High-sensitivity measurement of serum estrogens is important in adult and pediatric endocrinology and oncology. We developed a high-sensitivity liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for simultaneous measurement of estrone (E1) and estradiol (E2). Aliquots of 200 muL of serum were spiked with internal standard, extracted, derivatized with dansyl chloride, and analyzed by LC-MS/MS using 2-dimensional chromatographic separation. Total imprecision for the method was less than 11%; the limit of quantitation was 1 pg/mL. Reference intervals were established with samples from more than 900 healthy postmenopausal women, men, girls, and boys. Concentrations of estrogens in children reached adult levels by Tanner stage 3. In men and postmenopausal women, the median concentrations of total estrogens (E1 + E2) were 39 and 22 pg/mL, and the median E2/E1 ratios were 0.98 and 0.55, respectively. The method requires a small sample volume and has adequate sensitivity and specificity for analyzing estrogens in samples from postmenopausal women, men, and children.
Electrospray ionization has grown to be one of the most commonly used ionization techniques for mass spectrometry, and efforts continue to improve its performance. Typically, the sprayer tip must be very close to the entrance orifice of the mass spectrometer in order to maximize the conduction of ions from the sprayer into the mass spectrometer. However, because of space-charge repulsion, most ions never reach the sampling orifice. In this work, an industrial air amplifier, for which the working mechanism is based on venturi and coanda effects, was added between an electrospray ionization source and a time-of-flight mass spectrometer. When a series of reserpine solutions (0.5, 1.0, 5.0, and 10.0 microM) were monitored using mass spectrometry, an over 5-fold increase in m/z 609.3 ion intensity was measured for a separation distance of 14 mm between the electrospray tip and interface capillary inlet, as compared to when the electrospray tip was in its normal position 1 mm in front of the inlet without the amplifier. When a voltage was applied to the air amplifier to further assist in focusing the electrosprayed ions, an approximately 18-fold increase in m/z 609.3 ion intensity was obtained. In addition, a 34-fold reduction in method detection limit was observed.
BACKGROUND:Measurements of free thyroxine (FT 4 ) and free triiodothyronine (FT 3 ) are important for the diagnosis and monitoring of thyroid diseases. Considerable differences among methods limit their clinical utility, however, and accurate methods are needed for various clinical specimens. We describe a direct equilibrium dialysis (ED)-liquid chromatography (LC)/ tandem mass spectrometry (MS/MS) method for FT 4 and FT 3 .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.