PurposeThe aim of this study is to assess the influence exerted by the observer's dental specialization and compare patients' opinion with observers' opinion of the esthetics of maxillary single-tooth implants in the esthetic zone.MethodsForty-one adult patients, who were treated with a single implant in the esthetic zone, were enrolled in this study. Eight observers (2 periodontists, 2 prosthodontists, 2 orthodontists and 2 senior dental students) applied the pink esthetic score (PES)/white esthetic score (WES) to 41 implant-supported single restorations twice with an interval of 4 weeks. We used a visual analog scale (VAS) to assess the patient's satisfaction with the treatment outcome from an esthetic point of view.ResultsIn the PES/WES, very good and moderate intraobserver agreements were noted between the first and second rating. The mean total PES/WES was 11.19 ± 3.59. The mean PES was 5.17 ± 2.29 and mean WES was 6.02 ± 1.96. In the total PES/WES, the difference between the groups was not significant. However, in the WES, the difference between the groups was significant and prosthodontists were found to have assigned poorer ratings than the other groups. Periodontists gave higher ratings than prosthodontists and senior dental students. Orthodontists were clearly more critical than the other observers. The statistical analysis revealed statistically significant correlation between patients' esthetic perception and dentists' perception of the anterior tooth. However, the correlation between the total PES/WES and the VAS score for the first premolar was not statistically significant.ConclusionsThe PES/WES is an objective tool in rating the esthetics of implant supported single crowns and adjacent soft tissues. Orthodontists were the most critical observers, while periodontists were more generous than other observers. The statistical analysis revealed a statistically significant correlation between patients' esthetic perception and dentists' perception of the anterior tooth.
PurposeThe purpose of this study was to compare the phototoxic effects of blue light exposure on periodontal pathogens in both planktonic and biofilm cultures.MethodsStrains of Aggregatibacter actinomycetemcomitans, Fusobacterium nucleatum, and Porphyromonas gingivalis, in planktonic or biofilm states, were exposed to visible light at wavelengths of 400.520 nm. A quartz-tungsten-halogen lamp at a power density of 500 mW/cm2 was used for the light source. Each sample was exposed to 15, 30, 60, 90, or 120 seconds of each bacterial strain in the planktonic or biofilm state. Confocal scanning laser microscopy (CSLM) was used to observe the distribution of live/dead bacterial cells in biofilms. After light exposure, the bacterial killing rates were calculated from colony forming unit (CFU) counts.ResultsCLSM images that were obtained from biofilms showed a mixture of dead and live bacterial cells extending to a depth of 30-45 µm. Obvious differences in the live-to-dead bacterial cell ratio were found in P. gingivalis biofilm according to light exposure time. In the planktonic state, almost all bacteria were killed with 60 seconds of light exposure to F. nucleatum (99.1%) and with 15 seconds to P. gingivalis (100%). In the biofilm state, however, only the CFU of P. gingivalis demonstrated a decreasing tendency with increasing light exposure time, and there was a lower efficacy of phototoxicity to P. gingivalis as biofilm than in the planktonic state.ConclusionsBlue light exposure using a dental halogen curing unit is effective in reducing periodontal pathogens in the planktonic state. It is recommended that an adjunctive exogenous photosensitizer be used and that pathogens be exposed to visible light for clinical antimicrobial periodontal therapy.
PurposeThe purpose of this study was to evaluate the effects of implant shape and bone preparation on the primary stability of the implants using resonance frequency analysis.MethodsSixty bovine rib blocks were used for soft and hard bone models. Each rib block received two types of dental implant fixtures; a straight-screw type and tapered-screw type. Final drilling was done at three different depths for each implant type; 1 mm under-preparation, standard preparation, and 1 mm over-preparation. Immediately after fixture insertion, the implant stability quotient (ISQ) was measured for each implant.ResultsRegardless of the bone type, the ISQ values of the straight-screw type and tapered-screw type implants were not significantly different (P > 0.05). Depth of bone preparation had no significant effect on the ISQ value of straight-screw type implants (P > 0.05). For the tapered-screw type implants, under-preparation significantly increased the ISQ value (P < 0.05), whereas overpreparation significantly decreased the ISQ value (P < 0.05).ConclusionsWithin the limitations of this study, it is concluded that bone density seemed to have a prevailing effect over implant shape on primary stability. The primary stability of the tapered-screw type implants might be enhanced by delicate surgical techniques.
Periodontopathogens during orthodontic treatment were significantly reduced within 3 months of appliance removal. However, how long it takes to return to the preorthodontic composition of the subgingival microbiota and whether it happens at all remain to be seen.
PurposeThe purpose of this study was to evaluate the effect of photodynamic therapy (PDT) using erythrosine and a green light emitting diode (LED) light source on biofilms of Aggregatibacter actinomycetemcomitans attached to resorbable blasted media (RBM) and sandblasted, large-grit, acid-etched (SLA) titanium surfaces in vitro.MethodsRBM and SLA disks were subdivided into four groups, including one control group and three test groups (referred to as E0, E30, E60), in order to evaluate the effect of PDT on each surface. The E0 group was put into 500 µL of 20 µM erythrosine for 60 seconds without irradiation, the E30 group was put into erythrosine for 60 seconds and was then irradiated with a LED for 30 seconds, and the E60 group was put into erythrosine for 60 seconds and then irradiated with a LED for 60 seconds. After PDT, sonication was performed in order to detach the bacteria, the plates were incubated under anaerobic conditions on brucella blood agar plates for 72 hours at 37℃, and the number of colony-forming units (CFUs) was determined.ResultsSignificant differences were found between the control group and the E30 and E60 groups (P<0.05). A significantly lower quantity of CFU/mL was found in the E30 and E60 groups on both titanium disk surfaces. In confocal scanning laser microscopy images, increased bacterial death was observed when disks were irradiated for a longer period of time.ConclusionsThese findings suggest that PDT using erythrosine and a green LED is effective in reducing the viability of A. actinomycetemcomitans attached to surface-modified titanium in vitro.Graphical Abstract
PurposeThe purpose of this retrospective study was to evaluate the effect of patient compliance with supportive periodontal therapy (SPT) on tooth loss in Korean adults.MethodsThe periodontal records of 134 patients were reviewed for this study. They completed active periodontal treatment from 1999 to 2001 and were placed on a schedule of periodic follow-up visits for SPT. Patient compliance was classified into complete compliance (CC), erratic compliance (EC), and noncompliance (NC) groups. Re-examinations were carried out 11.0±0.8 years after the active periodontal treatment. The prognosis for each tooth was determined as good, questionable, or hopeless according to the bone loss observed in pretreatment radiographs.ResultsThe rate of tooth loss of the CC group was significantly lower than that of the NC group. The tooth loss/patient and the tooth loss/patient/year were not significantly different between the three groups. The rates of tooth loss in the good, questionable, and hopeless prognosis groups were 6.7%, 9.5%, and 13.2%, respectively. For the teeth with a good prognosis, the rate of tooth loss of the CC group was significantly lower than that of the NC group (0.4% vs. 5.1%). For the teeth with a questionable prognosis, the CC group showed a significantly lower rate of tooth loss than did the EC group (4.1% vs. 30.7%) or the NC group (4.1% vs. 25.6%). For the teeth with a hopeless prognosis, the rates of tooth loss were not significantly different among the three groups.ConclusionsWithin the limits of this study, the patients who showed a poor compliance with SPT were more likely to lose teeth than were the regularly compliant patients. However, the risk of tooth loss with a hopeless prognosis was high irrespective of the compliance.Graphical Abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.