Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths. Single-pixel X-ray detectors now have a resolving power of DeltaE < 5 eV for single 6-keV photons, and future X-ray astronomy missions anticipate the need for 1,000-pixel arrays. Here we report the demonstration of a superconducting detector that is easily fabricated and can readily be incorporated into such an array. Its sensitivity is already within an order of magnitude of that needed for CMB observations, and its energy resolution is similarly close to the targets required for future X-ray astronomy missions.
The authors have measured noise in thin-film superconducting coplanar waveguide resonators. This noise appears entirely as phase noise, equivalent to a jitter of the resonance frequency. In contrast, amplitude fluctuations are not observed at the sensitivity of their measurement. The ratio between the noise power in the phase and amplitude directions is large, in excess of 30 dB. These results have important implications for resonant readouts of various devices such as detectors, amplifiers, and qubits. They suggest that the phase noise is due to two-level systems in dielectric materials. © 2007 American Institute of Physics. ͓DOI: 10.1063/1.2711770͔ Thin-film superconducting microwave resonators are of interest for a number of applications, including the multiplexed readout of single electron transistors, 1 microwave kinetic inductance detectors ͑MKIDs͒, 2,3 normal metalinsulator-superconductor tunnel junction detectors, 4 superconducting quantum interference devices, 5,6 and qubits. 7,8 The device to be measured presents a variable dissipative or reactive load to the resonator, influencing the resonator quality factor Q r or frequency f r , respectively. Changes to both Q r and f r may be determined simultaneously by sensing the amplitude and phase of a microwave probe signal. 2 While several early demonstrations used hand-assembled lumpedelement circuits, 1,4,5 frequency-domain multiplexing of large arrays generally will require compact microlithographed high-Q r resonators. 1 Such resonators are also needed for strong coupling to charge qubits. 7 Noise in microlithographed resonators has been observed 2,3 and can be a limiting factor for device performance but is not well understood. In this letter, we report measurements of resonator noise, show how the noise spectra separate into amplitude and phase components, and discuss the physical origin of the noise.We studied quarter-wavelength coplanar waveguide ͑CPW͒ resonators 2 ͓Fig. 1͑a͔͒ with center strip widths w of 0.6-6 m and gaps g between the center strip and ground planes of 0.4-4 m, and with impedances Z 0 Ϸ 50 ⍀. Resonator lengths of 3 -7 mm produce resonance frequencies f r between 4 and 10 GHz. Frequency multiplexed arrays of up to 100 resonators are coupled to a single CPW feedline. The CPW circuits are patterned from a film of either Al ͑T c = 1.2 K͒ or Nb ͑T c = 9.2 K͒ on a crystalline substrate, either sapphire, Si, or Ge. The surfaces of the semiconductor substrates are not intentionally oxidized, although a native oxide due to air exposure is expected to be present.A microwave synthesizer at frequency f is used to excite a resonator. The transmitted signal is amplified with a cryogenic high electron mobility transistor ͑HEMT͒ amplifier and is compared to the original signal using an IQ mixer, whose output voltages I and Q are proportional to the in-phase and quadrature amplitudes of the transmitted signal 2,3 ͑see Fig. 2 inset͒. As f is varied, the output = ͓I , Q͔ T ͑the superscript T represents the transpose͒ traces out a resonance circle ͓Fi...
We present measurements of the temperature-dependent frequency shift of five niobium superconducting coplanar waveguide microresonators with center strip widths ranging from 3 to 50 m, taken at temperatures in the range of 100-800 mK, far below the 9.2 K transition temperature of niobium. These data agree well with the two-level system ͑TLS͒ theory. Fits to this theory provide information on the number of TLSs that interact with each resonator geometry. The geometrical scaling indicates a surface distribution of TLSs and the data are consistent with a TLS surface layer thickness of the order of a few nanometers, as might be expected for a native oxide layer. © 2008 American Institute of Physics. ͓DOI: 10.1063/1.2906373͔Superconducting microresonators have attracted substantial interest for low temperature detector applications due to the possibility of large-scale microwave frequency multiplexing.1-7 Such resonators are also being used in quantum computing experiments [8][9][10] and for sensing nanomechanical motion. 11 We previously reported that excess frequency noise is universally observed in these resonators and suggested that two-level systems ͑TLSs͒ in dielectric materials 14,15 may be responsible for this noise.12 TLS effects are also observed in superconducting qubits.9 The TLS hypothesis is strongly supported by the observed temperature dependence of the noise and also by the observation of temperature-dependent resonance frequency shifts that closely agree with the TLS theory. 13 To make further progress, it is essential to constrain the location of the TLSs, to determine whether they exist in the bulk substrate or in surface layers, perhaps oxides on the exposed metal or substrate surfaces, or in the interface layers between the metal films and the substrate. In this paper, we provide direct experimental evidence for a surface distribution of TLSs.TLSs are abundant in amorphous materials 14,15 and have electric dipole moments that couple to the electric field E ជ of our resonators. For microwave frequencies and at temperatures T between 100 mK and 1 K, the resonant interaction dominates over relaxation, which leads to a temperaturedependent variation of the dielectric constant given bywhere is the frequency, ⌿ is the complex digamma function, and ␦ = Pd 2 / 3⑀ represents the TLS-induced dielectric loss tangent at T = 0 for weak nonsaturating fields. Here, P and d are the two-level density of states and dipole moment, as introduced by Phillips. 16 Equation ͑1͒ has been extensively used to derive values of Pd 2 in amorphous materials. If TLSs are present in superconducting microresonators, their contribution to the dielectric constant described by Eq. ͑1͒ could be observable as a temperature-dependent shift in the resonance frequency. Indeed, it has recently been suggested that the small anomalous low-temperature frequency shifts often observed in superconducting microresonators may be due to TLS effects, 17,18 and, in fact, excellent fits to the TLS theory can be obtained. 13 Assuming that the TLSs ar...
Titanium nitride (TiN x ) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < T c < 5 K); b) the normal-state resistivity is large, ρ n ∼ 100 µΩ cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Resonators using reactively sputtered TiN films show remarkably low loss (Q i > 10 7 ) and have noise properties similar to resonators made using other materials, while the quasiparticle lifetimes are reasonably long, 10−200 µs. TiN microresonators should therefore reach sensitivities well below 10 −19 W Hz −1/2 .
We present measurements of the low-temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths s r ranging from 3 to 20 m. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as 1 / s r 1.6 . We show that this geometrical scaling is readily explained by a simple semiempirical model which assumes a surface distribution of independent two-level system fluctuators. These results allow the resonator geometry to be optimized for minimum noise. © 2008 American Institute of Physics. ͓DOI: 10.1063/1.2937855͔ Thin-film superconducting microresonators are of great interest for a number of applications ͑see Refs. 1-4 and references therein͒. Excess frequency noise is universally observed in these resonators 2,5,6 and is very likely caused by two-level systems ͑TLSs͒ in dielectric materials. 3,7 Indeed, the TLS hypothesis is supported by the observed dependence of the noise on resonator internal power 7,8 and temperature. 3 In a recent paper 4 ͑paper A hereafter͒, we presented measurements of the TLS-induced low-temperature frequency shifts of five niobium ͑T c = 9.2 K͒ coplanar waveguide ͑CPW͒ resonators with varying center strip widths s r . From the observed geometrical scaling of the frequency shifts ͑ϳ1 / s r ͒, we showed that the TLS must be located in a thin ͑few nanometer͒ layer on the surface of the CPW. In this letter, we propose a semiempirical TLS noise model that assumes this surface distribution, and we show that the model explains our measurements of the geometrical scaling of the noise.The device used for the experiment in this paper is exactly the same device used in paper A. In brief, the chip contains five CPW quarter-wavelength resonators ͑Z 0 Ϸ 50 ⍀, f r Ϸ 6 GHz͒ made by patterning a 120 nm thick Nb film deposited on a c-plane crystalline sapphire substrate. Each resonator is capacitively coupled to a common feedline, using a CPW coupler ͑coupling quality factor Q c ϳ 50 000͒ of length l c Х 200 m and with a common center-strip width of s c =3 m. The coupler is then widened into the resonator body, with a center-strip width of s r = 3, 5, 10, 20, or 50 m, and a length of l r ϳ 5 mm. The noise was measured using a standard IQ homodyne technique; 2,3 both the measurement setup and the analysis of the noise data are identical to our previous work. 7 The device is cooled in a dilution refrigerator to a base temperature of 55 mK. The fractional frequency noise spectra S ␦f ͑ ͒ / f r 2 of the five resonators were measured for microwave readout power P w in the range −61 to − 73 dBm; the −65 dBm spectra are shown in Fig. 1͑a͒. We clearly see that the noise has a common spectral shape but decreases as the center strip becomes wider. Unfortunately, the data for the lowest-noise ͑50 m͒ resonator are influenced by the noise floor of our cryogenic microwave amplifier, so we exclude this resonator from further discussion. The noise levels at = 2 kHz were retrieved from the n...
ABSTRACT. We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on microwave kinetic inductance detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs are nearly ideal, noiseless photon detectors, as they do not suffer from read noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is an integral field spectrograph (IFS) containing a lens-coupled 2024 pixel MKID array yielding a 20″ × 20″ field of view and has been deployed on the Palomar 200 inch and Lick 120 inch telescopes for 24 nights of observing. We present initial results showing that ARCONS and its MKID arrays are now a fully operational and powerful tool for astronomical observations.
Abstract:Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a photon-variable superconducting inductance in a lithographed microresonator, and is capable of functioning as a photon detector across the electromagnetic spectrum as well as a particle detector. Here we describe the first successful effort to create a photon-counting, energy-resolving ultraviolet, optical, and near infrared MKID focal plane array. These new Optical Lumped Element (OLE) MKID arrays have significant advantages over semiconductor detectors like charge coupled devices (CCDs). They can count individual photons with essentially no false counts and determine the energy and arrival time of every photon with good quantum efficiency. Their physical pixel size and maximum count rate is well matched with large telescopes. These capabilities enable powerful new astrophysical instruments usable from the ground and space. MKIDs could eventually supplant semiconductor detectors for most astronomical instrumentation, and will be useful for other disciplines such as quantum optics and biological imaging.
Design and analysis of multi-color confocal microscopy with a wavelength scanning detector Rev. Sci. Instrum. 83, 053704 (2012) Short wavelength thermography: Theoretical and experimental estimation of the optimal working wavelength J. Appl. Phys. 111, 084903 (2012) Hole shape effect induced optical response to permittivity change in palladium sub-wavelength hole arrays upon hydrogen exposure J. Appl. Phys. 111, 084502 (2012) Few-photon-level two-dimensional infrared imaging by coincidence frequency upconversion Appl. Phys. Lett. 100, 151102 (2012) Channelling optics for high quality imaging of sensory hair Rev. Sci. Instrum. 83, 045001 (2012) Additional information on Rev. Sci. Instrum. Microwave kinetic inductance detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at microwave frequencies, allowing the construction and readout of large arrays. Due to the microwave FDM, MKIDs do not require the complex cryogenic multiplexing electronics used for similar detectors, such as transition edge sensors, but instead transfer this complexity to room temperature electronics where they present a formidable signal processing challenge. In this paper, we describe the first successful effort to build a readout for a photon counting optical/near-IR astronomical instrument, the ARray Camera for Optical to Nearinfrared Spectrophotometry. This readout is based on open source hardware developed by the Collaboration for Astronomy Signal Processing and Electronics Research. Designed principally for radio telescope backends, it is flexible enough to be used for a variety of signal processing applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.