The FLV and the GLV showed the strongest abilities to detect GCL in patients with NAION. In addition, peripapillary NFL thickness was comparable to macular GCC thickness in detecting GCL. Therefore, macular GCC scans may provide a good alternative or a complementary practice to NFL scans in the detection of GCL in patients with NAION.
Fasting significantly decreases tear production and increases tear osmolarity; however, it does not deteriorate corneal topographic parameters and ocular aberrations in healthy subjects.
The decreased choroidal thickness of patients with migraine might be related to the vascular pathology of the disease. Further studies are needed to evaluate the etiopathologic relationship between choroidal thickness and migraine.
The results of Lenstar LS 900 noncontact biometry correlated with the results of UP. It may be used as an alternative method to UP for measuring CCT. Because of the mild underestimation of CCT by Lenstar, the measurements should be carefully evaluated in patients whose intraocular pressure must strictly be monitored.
Objectives:To evaluate the correlation of cataract surgical simulator and real-life surgical experience and its contribution to surgical training.Materials and Methods:Sixteen doctors in our department were divided into three groups based on their surgical experience. After being familiarized with the device, the participants were evaluated while performing the navigation, forceps, bimanual practice, anti-tremor and capsulorhexis stages. The capsulorhexis stage was repeated five times. Participants were also assessed while performing capsulorhexis again with their non-dominant hand. The influence of repetition and surgical experience on the recorded points was evaluated. P values below 0.05 were considered statistically significant.Results:There was correlation between the participants’ surgical experience and their scores in the capsulorhexis module. Their dominant hand was more successful than the non-dominant hand in capsulorhexis (p=0.004). Capsulorhexis scores increased with repetition (p=0.001).Conclusion:Results achieved with the cataract surgery simulation device correlate with surgical experience. The increase in performance upon repeated practice indicates that the simulator supports surgical training.
In our study, the systemic administration of Cisplatin and Paclitaxel affected the peripapillary RNFL thicknesses and visual field indices as revealed by FDT perimetry. OCT and FDT perimetry may be adjunctive tools for the screening of ocular toxicity in patients treated with these agents.
Objectives:To examine changes in corneal endothelial cell density (ECD) in different stages of keratoconus and evaluate its correlation with corneal tomographic parameters.Materials and Methods:Two hundred six patients with keratoconus were enrolled in the study. Corneal topography was performed by Sirius (CSO, Italy), which has a rotating Scheimpflug camera and a Placido disc topographer. Automatic endothelial analysis was done with the non-contact endothelial microscope (20x probe) of Confoscan-4 (NIDEK, Japan). The eyes were classified into stages based on steepest keratometric value as follows: mild <45 D; moderate 45-52 D; severe >52 D and according to thinnest cornea thickness (TCT) as <400 μm, 400-450 μm, and >450 μm. Tomographic and endothelial cell parameters were compared among the groups using Kruskal-Wallis test and the correlations between them were analyzed using Spearman correlation.Results:The study included 391 eyes of 100 male (24.29±7.7 years, range 11-47 years) and 106 female (26.26±7.5 years, range 13-45 years) patients (p=0.07). Mean ECD values were 2628±262 cells/mm2, 2541.9±260.4 cells/mm2, and 2414.6±384.3 cells/mm2 in mild, moderate, and severe keratoconus, respectively (p<0.001) and 2592.3±277 cells/mm2, 2502±307 cells/mm2 and 2348±296 cells/mm2 in corneas with TCT values >450 µm, 400-450 µm, and <400 µm, respectively (p<0.001). ECD showed significant negative correlation with keratometric and elevation parameters and positive correlation with pachymetric parameters (p<0.05).Conclusion:As endothelial cell numbers seem to decrease with the progression of keratoconus, specular/confocal microscopy screening should be carried out, especially in eyes with advanced stages and corneas with TCT <400 µm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.