The infection burden associated with CIED implantation is increasing over time and is associated with prolonged hospital stays and high financial costs.
The replacement burden for PMs has remained constant, while the replacement burden for ICDs has decreased. This is likely due to the stability of the patient population receiving PMs and technology maturity. Alternatively, the indications for ICD implantation have broadened, resulting in an increased number of primary ICD implantations. The age and comorbidities are increasing in those patients receiving ICDs while the PM population is stable. These data suggest that monitoring of replacement burden is warranted, given the changing populations, their disparate clinical outcomes, and economic implications to the health care system.
There is a steady growth in the use of permanent pacemakers in the United States. Although DDD device use is increasing, whereas single-chamber ventricular pacemaker use is decreasing. Patients are becoming older and have more medical comorbidities. These trends have important health care policy implications.
Monthly review of HF device diagnostic data identifies patients at a higher risk of HF hospitalizations within the subsequent month. (PARTNERS HF: Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure; NCT00279955).
Atrial arrhythmias occur frequently in the denervated transplanted heart, often in the absence of significant rejection. Late atrial fibrillation may be associated with an increased all-cause mortality.
Background-The planar QRS-T angle can be easily obtained from standard 12-lead ECGs, but its predictive ability is not established. We sought to determine the predictive ability of the planar QRS-T angle in patients with nonischemic cardiomyopathy and to assess QRS-T angle behavior over time.
Methods and Results-Baseline QRS-T angles from 455 patients in the Defibrillators in Nonischemic CardiomyopathyTreatment Evaluation (DEFINITE) trial were measured. All patients had nonischemic cardiomyopathy, New York Heart Association class I to III heart failure, and nonsustained ventricular tachycardia or frequent ventricular ectopy. The primary end point (a composite of total mortality, appropriate implantable cardioverter-defibrillator shock, or resuscitated cardiac arrest) occurred in 25 of 172 patients (14.5%) with a QRS-T angle Յ90°and in 72 of 283 patients (25.4%) with a QRS-T angle Ͼ90°(hazard ratio, 1.93; 95% confidence interval, 1.23 to 3.05; Pϭ0.002). A QRS-T angle Ͼ90°remained a significant predictor of the primary end point (Pϭ0.039) after adjustment for treatment group, age, gender, QRS duration, left bundle-branch block, left ventricular ejection fraction, New York Heart Association class III, atrial fibrillation, and diabetes mellitus. The secondary end point (total mortality) occurred in 17 of the 172 patients (9.9%) with a QRS-T angle Յ90°and in 49 of the 283 patients (17.3%) with a QRS-T angle Ͼ90°(hazard ratio, 1.79; 95% confidence interval, 1.03 to 3.10; Pϭ0.016). A sample of 152 patients with multiple follow-up ECGs was analyzed to assess temporal QRS-T angle behavior. Changes in the QRS-T angle correlated with changes in left ventricular ejection fraction and QRS duration over time (PϽ0.001).
Conclusions-A planar QRS-T angle
AimsTo test recommended implantable cardioverter defibrillator (ICD) follow-up methods by ‘in-person evaluations’ (IPE) vs. ‘remote Home Monitoring’ (HM).Methods and resultsICD patients were randomized 2:1 to automatic HM or to Conventional monitoring, with follow-up checks scheduled at 3, 6, 9, 12, and 15 months post-implant. Conventional patients were evaluated with IPE only. Home Monitoring patients were assessed remotely only for 1 year between 3 and 15 month evaluations. Adherence to follow-up was measured. HM and Conventional patients were similar (age 63 years, 72% male, left ventricular ejection fraction 29%, primary prevention 73%, DDD 57%). Conventional management suffered greater patient attrition during the trial (20.1 vs. 14.2% in HM, P = 0.007). Three month follow-up occurred in 84% in both groups. There was 100% adherence (5 of 5 checks) in 47.3% Conventional vs. 59.7% HM (P < 0.001). Between 3 and 15 months, HM exhibited superior (2.2×) adherence to scheduled follow-up [incidence of failed follow up was 146 of 2421 (6.0%) in HM vs. 145 of 1098 (13.2%) in Conventional, P < 0.001] and punctuality. In HM (daily transmission success rate median 91%), transmission loss caused only 22 of 2275 (0.97%) failed HM evaluations between 3 and 15 months; others resulted from clinic oversight. Overall IPE failure rate in Conventional [193 of 1841 (10.5%) exceeded that in HM [97 of 1484 (6.5%), P < 0.001] by 62%, i.e. HM patients remained more loyal to IPE when this was mandated.ConclusionAutomatic remote monitoring better preserves patient retention and adherence to scheduled follow-up compared with IPE.Clinical trial registrationNCT00336284.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.