Chemical speciation of binary complexes of Ca(II), Zn(II) and Mn(II) with L-proline is investigated pH-metrically in acetonitrile-water mixtures. The stability constants are calculated using the computer program MINIQUAD75. The best-fit chemical models are selected based on statistical parameters and residual analysis. The models for the binary species contained ML + , MLH 2+ and ML 2 H + for Ca(II), Zn(II) and Mn(II). The trend in variation of stability constants with change in the dielectric constant of the medium is explained on the basis of structure forming nature of acetonitrile. Distribution of the species with pH at different variations (0.0-60.0% v/v) in acetonitrile-water mixtures is also presented.
Objective: The present paper describes a simple, accurate, and precise reversed-phase high-performance liquid chromatography (HPLC) method for rapid and simultaneous quantification of dolutegravir (DTG) and rilpivirine (RPV) in bulk and pharmaceutical dosage form and rat plasma.
Methods: The chromatographic separation was achieved on Phenomenex C18 (150x4.6mm, 5μm). Mobile phase contained a mixture of 0.1% Ortho phosphoric acid and acetonitrile in the rato of 60:40 v/v, flow rate 1.0ml/min and ultraviolet detection at 262nm.
Results: The retention time of DTG and RPV was 4.35 min and 7.73 min, respectively. The proposed method shows a good linearity in the concentration range of 10–150 μg/ml for DTG and 5–75 μg/ml for RPV under optimized conditions. Precision and recovery study results are in between 98 and 102%. In the entire robustness conditions, percentage relative standard deviation is <2.0%. Degradation has minimum effect in stress condition and solutions are stable up to 24 h. DTG and RPV drugs are release 98% at 2 h in rat body.
Conclusion: This method is validated for different analytical performance parameters like linearity. Precision, accuracy, limit of detection, limit of quantification, robustness, and pharmacokinetic study were determined according to the International Conference of Harmonization (ICH) Q2B guidelines. All the parameters of validation were found in the acceptance range of ICH guidelines. The same method is also applied for plasma samples study in bioanalytical work.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.