Paediatric patients undergoing surgical procedures commonly require some volume of blood or blood component replacement in the perioperative period. Paediatric patients undergoing major surgery associated with substantial blood loss should be evaluated pre-operatively. Pre-operative correction of anaemia may be done considering the age, plasma volume status, clinical status and comorbidities. Maximum allowable blood loss (MABL) for surgery must be calculated, and appropriate quantity of blood and blood components should be arranged. Intraoperative monitoring of blood loss should be done, and volume of transfusion should be calculated in a protocol based manner considering the volemia and the trigger threshold for transfusion for the patient and the MABL. Early haemostasis should be achieved by judicious administration of red blood cells, blood components and pharmacological agents.
BackgroundSudden loss of airway in patients in the lateral position has always been proven to be difficult to manage with conventional laryngoscopy. We performed a randomized controlled trial to prove the success rate of ventilation and intubation in the lateral position via intubating laryngeal mask airway (ILMA).MethodsNinety patients were divided into three groups of 30 patients each, positioned supine, right lateral, and left lateral randomly. Each group comprised of both sexes of American Society of Anesthesiologists grade I and II, aged between 18-55 years with normal airway posted for surgery under general anesthesia. Patients were pre-medicated with fentanyl followed by induction with propofol and neuromuscular blockade with rocuronium. ILMA was inserted and blind tracheal intubation via ILMA was done. The success rate, time taken and the number of adjusting maneuvers used for both procedures were recorded. The data was tabulated and analyzed using ANOVA (analysis of variance), multiple 't' test and chi square.ResultsThe success rate of intubation (96%) and time taken in insertion and intubation was found to be quite similar in all the three groups.ConclusionsWe conclude that the ILMA has an important role to play in the emergency management of airways in patients in the lateral position in terms of ease, success rate and time taken.
We conclude that despite a small, transient increase in serum triglycerides and pancreatic enzymes, short-term propofol administration in recommended dosages in children of ASA status I and II aged between 1 month and 36 months does not produce any clinically significant effect on serum lipids and pancreatic enzymes.
Abstract:Esophageal Atresia (EA) with Tracheoesophageal fistula (TEF) can be complicated by aspiration, respiratory distress and other congenital anomalies. We present a case of 1 day old neonate posted for Tracheoesophageal fistula repair who was found to have subglottic stenosis after induction of anaesthesia. A Cormac -Lehane grade 1 direct laryngoscopic view was obtained following induction of anaesthesia, however it was not possible to intubate the patient with even smallest size 2.0 mm endotracheal tube. Ventilation with size 1 Laryngeal mask airway was adequate. Failed intubation with smallest size endotracheal tube led us to suspect subglottic stenosis. In view of necessity of endotracheal intubation in EA with TEF surgery, this case highlights the importance of management of unexpected subglottic stenosis in neonate in an emergency setting.
Background:Ambu® Aura-i™, a recently introduced second generation supraglottic airway device has been designed to function as an independent ventilatory device as well as a conduit for passage of conventional cuffed tracheal tubes through it. There is dearth of literature on experience of tracheal intubation through intubating laryngeal mask airway (ILMA) in paediatric age group. This study was conducted to study the ventilatory effectiveness and the intubating characteristics of Ambu® Aura-i™ in paediatric patients.Aim:To study the effectiveness of Ambu ® Aura-i ™ as a supraglottic device for its ventilatory effectiveness and intubation characteristics in paediatric patients.Objectives:To study the Ventilatory effectiveness of Ambu ® Aura-i ™ in terms of: 1) Time taken in insertion of Ambu ® Aura-i ™. 2) No of attempts made for successful insertion of Ambu ® Aura-i™. 3) Tidal volume attained on positive pressure ventilation. 4) Etco2, Spo2 and Leak pressure achieved. To study the Intubating characterstics of Ambu ® Aura-i ™ in terms of :- 1) Grade of alignment of the ventilating orifice achieved in relation to the larynx in the fibre optic view. 2) Time taken in intubation through Ambu ® Aura-i ™. 3) Number of attempts made in intubation. 4) Time taken for removal of the Ambu ® Aura-i ™ after intubation through it has been accomplished.Method:Sixty three children undergoing elective surgery under general anaesthesia requiring intubation of trachea, weighing between 5-30 kg were stratified into 3 groups (n= 21) each. Ambu® Aura-i™ size 1.5 , 2.0 ,2.5 were used based on their body weight for airway management. Ventilatory effectiveness was studied in terms of success rate, number of attempts made at insertion, time taken in insertion, tidal volume delivered and leak pressure achieved. Intubating characterstics studied during fibreoptic guided tracheal intubation included grade of alignment of the ventilating orifice achieved in relation to the larynx in fibre optic view, time taken in fibreoptic guided tracheal intubation, success rate and number of attempts made at intubation. Time taken in removal of the device and complications observed were also recorded.Results:Ambu® Aura-i™ insertion, fibreoptic guided tracheal intubation and device removal were successful in all the patients in first attempt. The mean time taken in successful device insertion was 10.83±2.04 sec. The mean tidal volume delivered was 7.88±1.33 ml/kg body weight and mean leak pressure achieved was 16.27±5.2 cm H2O. The fibreoptic guided intubation was possible in first attempt in 100% of the patients (n=63). The Fibre optic view was grade 1 in 82.55% patients (n=52 /63) and grade 2 in 17.46% (n=11/ 63) patients. The mean time taken in fibre optic guided intubation was 12.68 ±2.82 sec. The mean time taken in removal of the device over the tracheal tube was 12.27 sec. There was no significant incidence of trauma to soft tissues, sore throat, laryngospasm or hoarseness of voice.Conclusion:On the basis of observations of this study, we conclude that...
Background and aim The primary aim of the study was to compare the intubation characteristics and effectiveness of intubating laryngeal mask airway (ILMA) and Ambu® Aura-i™ as a conduit for facilitating fiberoptic-guided intubation. Methods Eighty patients were enrolled in the randomized-controlled hospital-based study. After inducing general anesthesia, an appropriately sized ILMA (group 1)/Ambu Aura-I (group 2) was placed. Fiberoptic assessment of the glottic view was done followed by fiberoptic-guided tracheal intubation. The time taken for the insertion of ILMA/Ambu Aura-i, glottic view grading, time taken for fiberoptic-guided intubation, ease of intubation, time taken for the removal of ILMA/Ambu Aura-i were recorded. Data analysis was done using the two-tailed independent t-test, paired t-test, and Fisher's exact probability test. Result Anthropometric and airway parameters were similar in both groups. The success rate of the insertion of both devices was 100%. In group 1, the mean time taken for the insertion was 20.53±1.91, and it was 13.98±2.4 in group 2 (P<0.001S). Fiberoptic assessment of the glottic view in group 1 (ILMA group) was grade 1 in 80% of the patients, whereas it was 92% in group 2 (Ambu Aura-i) (P=0.54). The mean time taken for fiberoptic-guided intubation was 14.95±1.85 in group 1 and 14.15±1.37 in group 2 (P>0.001). No significant difference was observed according to the number of attempts in intubating through ILMA/Ambu Aura-i. Seventy-five percent (75%) in group 1 and 87.5% in group 2 were successfully inserted on the first attempt (= 0.33). The time taken for the removal of the device was 11.87 +1.265 seconds in group 1 and 11.25±1.58 seconds in group 2 (P=0.054). Conclusion The Ambu Aura-i scores superiorly over ILMA in requiring less time for successful insertion on the basis of statistical analysis and hence appears to be a better independent ventilatory device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.