The underlying physical properties of microfluidic tools have led to new biological insights through the development of microsystems that can manipulate, mimic and measure biology at a resolution that has not been possible with macroscale tools. Microsystems readily handle sub-microlitre volumes, precisely route predictable laminar fluid flows and match both perturbations and measurements to the length scales and timescales of biological systems. The advent of fabrication techniques that do not require highly specialized engineering facilities is fuelling the broad dissemination of microfluidic systems and their adaptation to specific biological questions. We describe how our understanding of molecular and cell biology is being and will continue to be advanced by precision microfluidic approaches and posit that microfluidic tools — in conjunction with advanced imaging, bioinformatics and molecular biology approaches — will transform biology into a precision science.
To measure protein isoforms in individual mammalian cells we report single-cell resolution isoelectric focusing (scIEF) and high-selectivity immunoprobing. Microfluidic design and photoactivatable materials establish the tunable pH gradients required by IEF and precisely control transport and handling of each 17 pL cell lysate during analysis. scIEF resolves protein isoforms with resolution down to single-charge unit differences, including both endogenous cytoplasmic and nuclear proteins from individual mammalian cells.
Degas-driven flow is a novel phenomenon used to propel fluids in poly(dimethylsiloxane) (PDMS)-based microfluidic devices without requiring any external power. This method takes advantage of the inherently high porosity and air solubility of PDMS by removing air molecules from the bulk PDMS before initiating the flow. The dynamics of degas-driven flow are dependent on the channel and device geometries and are highly sensitive to temporal parameters. These dependencies have not been fully characterized, hindering broad use of degas-driven flow as a microfluidic pumping mechanism. Here, we characterize, for the first time, the effect of various parameters on the dynamics of degas-driven flow, including channel geometry, PDMS thickness, PDMS exposure area, vacuum degassing time, and idle time at atmospheric pressure before loading. We investigate the effect of these parameters on flow velocity as well as channel fill time for the degas-driven flow process. Using our devices, we achieved reproducible flow with a standard deviation of less than 8% for flow velocity, as well as maximum flow rates of up to 3 nL∕s and mean flow rates of approximately 1-1.5 nL∕s. Parameters such as channel surface area and PDMS chip exposure area were found to have negligible impact on degas-driven flow dynamics, whereas channel cross-sectional area, degas time, PDMS thickness, and idle time were found to have a larger impact. In addition, we develop a physical model that can predict mean flow velocities within 6% of experimental values and can be used as a tool for future design of PDMS-based microfluidic devices that utilize degas-driven flow.
We describe a novel isoelectric point photoswitching phenomenon in both wild-type Aequorea victoria (av) GFP and the E222G mutant Aequorea coerulescens (ac) GFP. A combination of time-resolved microfluidic isoelectric focusing (IEF) and in situ antibody blotting IEF were employed to monitor dark (non-fluorescent) and bright (fluorescent) GFP populations. Through IEF, each population was observed to exhibit distinct isoelectric points (pI) and, thus, distinct formal electrostatic charges. Experimentally observed interconversion between the dark, higher pI and bright, lower pI GFP populations is tightly controlled by differential UV and blue light exposure. The stoichiometry and kinetics of charge transfer tied to this reversible photobleaching process are deduced. In concert with a reaction-transport model of bistable reversible charge and fluorescence photoswitching, the on-chip measurements of population interconversion rates suggest the potential for both rheostatic and discrete switch-like modulation of the electrostatic charge of GFPs depending on the illumination profile. We estimate that 3–4 formal charges distinguish the bright and dark populations of avGFP, compared to one charge for those of acGFP. Given the proposed role of E222 as a bridge between internal and exit hydrogen bond clusters within the GFP β-barrel, the difference in charge switching magnitude between the two mutants provides intriguing evidence for the proton wire hypothesis of proton transport within the GFP structure, and of proton exchange with the bulk solvent. Our facile dynamic and probed IEF assays should find widespread use in analytical screening and quantitative kinetic analysis of photoswitching and other charge switching processes in response to stimuli including light, temperature, or binding/cleavage events.
By combining isoelectric focusing (IEF) with subsequent gel electrophoresis, two-dimensional electrophoresis (2DE) affords more specific characterization of proteins than each constituent unit separation. In a new approach to integrating the two assay dimensions in a microscope slide-sized glass device, we introduce microfluidic 2DE using photopatterned polyacrylamide (PA) gel elements housed in a millimeter-scale, 20 micron-deep chamber. The microchamber minimizes information loss inherent to channel network architectures commonly used for microfluidic 2DE. To define the IEF axis along a ‘lane’ at the top of the chamber, we used free solution carrier ampholytes and immobilized acrylamido buffers in the PA gels. This approach yielded high resolution (0.1 pH units) and rapid (<20 min) IEF. Next, protein transfer to the second dimension was accomplished using chemical mobilization perpendicular to the IEF axis. Mobilization drove focused proteins off the IEF lane and into a region for protein gel electrophoresis. Using fluorescently labeled proteins, we observed transfer induced band broadening factors ~7.5-fold lower than those observed in microchannel networks. Both native polyacrylamide gel electrophoresis (PAGE) and pore-limit electrophoresis (PLE) were studied as the second assay dimension and completed in <15 min. PLE yields protein molecular mass information without the need for ionic surfactant or reducing agents, simplifying device design and operation. Microchamber-based 2DE unifies two independent separation dimensions in a single device with minimal transfer-associated information losses. Peak capacities for the total assay ranged from 256 to 35 with <1 hr assay duration. The rapid microchamber 2DE assay has the potential to bridge an existing gap in targeted proteomics for protein biomarker validation and systems biology that may complement recent innovation in mass spectrometry.
To measure protein isoforms in individual mammalian cells,w er eport single-cell resolution isoelectric focusing (scIEF) and high-selectivity immunoprobing.M icrofluidic design and photoactivatable materials establish the tunable pH gradients required by IEF and precisely control the transport and handling of each 17-pL cell lysate during analysis.T he scIEF assay resolves protein isoforms with resolution down to as ingle-charge unit, including both endogenous cytoplasmic and nuclear proteins from individual mammalian cells.
MicroRNAs (miRNA) are short, noncoding RNAs that have been implicated in many diseases, including cancers. Because miRNAs are dysregulated in disease, miRNAs show promise as highly stable biomarkers. Formalin-fixed, paraffin-embedded (FFPE) tissue is a valuable sample type to assay for biomolecules because it is a convenient storage method and is often used by pathologists for histological staining. However, extracting biomolecules from FFPE tissue is challenging because of the presence of cellular and extracellular proteins, formaldehyde cross-links, and paraffin. Moreover, most protocols to measure miRNA in FFPE tissue are time-consuming and laborious. Here, we report a simple protocol to directly measure miRNA from formalin-fixed cells, FFPE tissue sections after paraffin is removed, and FFPE tissue sections using encoded hydrogel microparticles fabricated using stop flow lithography. Measurements by these particles show agreement between formalin-fixed cells and fresh cells, and measurement of FFPE tissue with paraffin is 10% less than FFPE tissue when paraffin is removed before the assay. When normal and tumor FFPE tissue are compared using this microparticle assay, we observe differential miRNA signal for oncogenic miRNAs and tumor suppressing miRNAs. This approach reduces assay times, reduces the use of hazardous chemicals to remove paraffin, and provides a sensitive, quantitative, and multiplexed measurement of miRNA in FFPE tissue.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.