Mechanical assist devices in refractory cardiac arrest are increasingly employed. We compared the hemodynamics and organ perfusion during cardiac arrest with either veno-arterial extracorporeal membrane oxygenation (ECMO) or biventricular assisted circulation combining left- and right-sided impeller devices (BiPella) in an acute experimental setting. Twenty pigs were randomized in two equal groups receiving circulatory support either by ECMO or by BiPella during 40 minutes of ventricular fibrillation (VF) followed by three attempts of cardioversion, and if successful, 60 minute observation with spontaneous, unsupported circulation. Hemodynamic variables were continuously recorded. Tissue perfusion was evaluated by fluorescent microsphere injections. Cardiac function was visualized by intracardiac echocardiography. During VF device output, carotid flow, kidney perfusion, mean aortic pressure (AOPmean), and mean left ventricular pressure (LVPmean) were all significantly higher in the ECMO group, and serum-lactate values were lower compared with the BiPella group. No difference in myocardial or cerebral perfusion was observed between groups. In 15 animals with sustained cardiac function for 60 minutes after return of spontaneous circulation, left ventricular subendocardial blood flow rate averaged 0.59 ± 0.05 ml/min/gm during VF compared with 0.31 ± 0.07 ml/min/gm in five animals with circulatory collapse (p = 0.005). Corresponding values for the midmyocardium was 0.91 ± 0.06 vs. 0.65 ± 0.15 ml/min/gm (p = 0.085). Both BiPella and ECMO could sustain vital organ function. ECMO provided a more optimal systemic circulatory support related to near physiologic output. Myocardial tissue perfusion and sustained cardiac function were related to coronary perfusion pressure during VF, irrespective of mode of circulatory support.
Introduction: Venoarterial extracorporeal membrane oxygenation is widely used as mechanical circulatory support for severe heart failure. A major concern with this treatment modality is left ventricular distension due to inability to overcome the afterload created by the extracorporeal membrane oxygenation circuit. The present porcine study evaluates coronary circulation, myocardial perfusion and ventricular distension during venoarterial extracorporeal membrane oxygenation. Methods: Ten anesthetized open-chest pigs were cannulated and put on cardiopulmonary bypass. Heart failure was achieved by 90 minutes of aortic cross-clamping with insufficient cardioplegic protection. After declamping, the animals were supported by venoarterial extracorporeal membrane oxygenation for 3 hours. Continuous haemodynamic measurements were performed at baseline, during cardiopulmonary bypass/aortic cross-clamping and during venoarterial extracorporeal membrane oxygenation. Fluorescent microsphere injections at baseline and after 1, 2 and 3 hours on venoarterial extracorporeal membrane oxygenation evaluated myocardial perfusion. Left ventricular function and distension were assessed by epicardial echocardiography. Results: The myocardial injury caused by 90 minutes of ischaemia resulted in a poorly contracting myocardium, necessitating venoarterial extracorporeal membrane oxygenation in all animals. The circulatory support maintained the mean arterial blood pressure within a satisfactory range. A hyperaemic left anterior descending coronary artery flow while on extracorporeal membrane oxygenation was observed compared to baseline. Myocardial tissue perfusion measured by microspheres was low, especially in the subendocardium. Echocardiography revealed myocardial tissue oedema, a virtually empty left ventricle, and a left ventricular output that remained negligible throughout the extracorporeal membrane oxygenation run. Conclusion: Coronary artery blood flow is maintained during venoarterial extracorporeal membrane oxygenation after cardiopulmonary bypass and cardioplegic arrest despite severely affected performance of the left ventricle. Myocardial perfusion decreases, however, presumably due to rapid development of myocardial tissue oedema.
Myocardial protection for two hours of polarizing cardioplegic arrest with STH-POL in oxygenated blood is non-inferior compared to STH-2 blood cardioplegia. STH-POL cardioplegia alleviates the mismatch between myocardial function and perfusion after weaning from CPB.
ObjectivesRheumatic heart disease (RHD) is a major burden in low-income and middle-income countries (LMICs). Cardiac surgery is the only curative treatment. Little is known about patients with severe chronic RHD operated in LMICs, and challenges regarding postoperative follow-up are an important issue. At Tikur Anbessa Specialised Hospital, Addis Ababa, Ethiopia, we aimed to evaluate the course and 12-month outcome of patients with severe chronic RHD who received open-heart surgery, as compared with the natural course of controls waiting for surgery and undergoing only medical treatment.MethodsClinical data and outcome measures were registered in 46 patients operated during five missions from March 2016 to November 2019, and compared with the first-year course in a cohort of 49 controls from the same hospital’s waiting list for surgery. Adverse events were death or complications such as stroke, other thromboembolic events, bleeding, hospitalisation for heart failure and infectious endocarditis.ResultsSurvival at 12 months was 89% and survival free from complications was 80% in the surgical group. Despite undergoing open-heart surgery, with its inherent risks, outcome measures of the surgical group were non-inferior to the natural course of the control group in the first year after inclusion on the waiting list (p≥0.45). All except six surgical patients were in New York Heart Association class I after 12 months and 84% had resumed working.ConclusionsCardiac surgery for severe chronic RHD is feasible in LMICs if the service is structured and planned. Rates of survival and survival free from complications were similar to those of controls at 12 months. Functional level and resumption of work were high in the surgical group. Whether the patients who underwent cardiac surgery will have better long-term prognosis, in line with what is known in high-income countries, needs to be evaluated in future studies.
Introduction Left ventricular distension is a major concern with postcardiotomy veno-arterial extracorporeal membrane oxygenation (VA-ECMO) supporting a critical heart failure after cardiac surgery. This porcine study evaluates the effects of left ventricular venting on cardiac function during ECMO-supported circulation and after weaning from ECMO. Methods Twenty anaesthetised open-chest pigs were put on cardiopulmonary bypass with aortic cross-clamping and suboptimal cardioplegic arrest for 40 min. After declamping and defibrillation, the animals were supported by VA-ECMO for 180 min either with or without additional left ventricular venting. Continuous haemodynamic evaluations were performed at baseline and at cardiac arrest, during VA-ECMO and for 120 min after weaning from circulatory support. Left ventricular perfusion and function were evaluated with microspheres, pressure-volume loops and epicardial echocardiography at baseline and after 1 and 2 h with unsupported circulation. Results In vented animals both mean aortic and left ventricular peak systolic pressure increased at the end of the ECMO-supported period compared to those not vented and remained increased also after weaning. Both at 60 min and 120 min after weaning from circulatory support, left ventricular stroke work and pressure-volume area were increased in vented compared to not vented animals. At 120 min left ventricular stroke volume was increased in vented compared to not vented animals, myocardial perfusion did not differ. The left ventricular mechanical efficiency, defined as the ratio between pressure volume area and myocardial perfusion, was increased (53.2 ± 5 vs 36.2 ± 2.1 J/mL/g, p = 0.011) in vented- compared to not vented hearts. Conclusion This experimental study demonstrate that left ventricular venting during post-cardiotomy veno-arterial ECMO for 3 h attenuates deterioration of left ventricular function and haemodynamics early after weaning from circulatory support.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.