We hypothesized that an exogenous bone growth factor could augment healing of a tendon graft in a bone tunnel in a rabbit anterior cruciate ligament-reconstruction model. Seventy rabbits underwent bilateral anterior cruciate ligament reconstructions with a semitendinosus tendon graft. One limb received a collagen sponge carrier vehicle containing a mixture of bone-derived proteins while the contralateral limb was treated with either no sponge or a sponge without bone-derived proteins. The reconstruction was evaluated at 2, 4, or 8 weeks with histologic, biomechanical, and magnetic resonance imaging analysis. Histologic analysis demonstrated that specimens treated with bone-derived proteins had a more consistent, dense interface tissue and closer apposition of new bone to the graft, with occasional formation of a fibrocartilaginous interface, when compared with control specimens. The treated specimens had significantly higher load-to-failure rates than did control specimens. Treatment with bone-derived proteins resulted in an average increase in tensile strength of 65%. The treated specimens were stronger than control specimens at each time point, but the difference was greatest at 8 weeks. On the basis of signal characteristics and new bone formation, magnetic resonance imaging was useful for predicting which limb was treated, the site of failure, and the limbs with higher load-to-failure values. This study demonstrates the potential for augmenting tendon healing in an intraarticular bone tunnel using an osteoinductive growth factor.
Based on results of this study, and given the low turnover of collagen in ligaments, it is unlikely that a 2- to 3-day per month increase in circulating estrogen would result in rapid, clinically significant alterations in material properties of the anterior cruciate ligament in vivo. The etiology of noncontact anterior cruciate ligament injuries is complex and multifactorial in nature, meriting further investigation.
Patients may present with a primary complaint of intra-articular knee masses causing mechanical symptoms of snapping or locking. If the history, physical examination, laboratory tests, and imaging studies point to a benign process, acceptable treatment consists of arthroscopic excision and postoperative pathology analysis. As reported in several case series, the final diagnosis can be pigmented villonodular synovitis, localized nodular synovitis, hemangioma, lipoma, or rheumatoid nodules. In this case presentation, a 39-year-old man with no previous medical conditions and a negative preoperative chest radiograph underwent arthroscopic surgery for a single intra-articular knee mass. The unexpected diagnosis, after pathology review and further medical work-up, was arthritis secondary to chronic sarcoidosis.
Background
Perianchor cyst formation (PCF) can occur after arthroscopic rotator cuff repair with poly-L-lactic acid (PLLA) anchors; however, little is known about PCF after all-suture anchor (ASA) use.
Methods
We reviewed patients who underwent double-row arthroscopic rotator cuff repair from 2012 to 2017 with ASAs implanted in the medial row and PLLA anchors in the lateral row. We evaluated PCF (graded on magnetic resonance imaging) and compared physical examination and functional surveys between patients with PCF (WC) and without PCF (WoC) at long-term follow-up.
Results
Among twenty-two patients (23 shoulders), 93% of PLLA anchors (vs. 79% ASA) displayed a grade 0 PCF,
P
= .100. No PLLA anchors had a grade 3 or 4 PCF, compared to 11% of ASAs,
P
= .158. At a mean postoperative follow-up time of 113 weeks, there was no significant difference between WC and WoC cohorts with regard to range of motion, rotator cuff strength, American Shoulder and Elbow Surgeons survey scores, or retear rates. However, the WoC cohort had a significantly higher University of California at Los Angeles shoulder survey score at final follow-up (34.3 WoC vs. 30.9 WC,
P
= .024).
Conclusion
No difference was found in PCF between ASAs and PLLA anchors. At long-term follow-up, WoC patients had significantly improved functional outcome scores, based on the University of California at Los Angeles survey, but equivalent range of motion and rotator cuff strength examinations compared with WC patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.