Two conflicting theories exist concerning the stress pattern for the proximal lateral aspect of the human femur. According to the classic theory of Pauwels, a bending moment on the femur leads to compression medially and to tension laterally. The alternative theory is that muscle forces contribute to a moment-free loading of the femur, with both the medial and lateral cortices subjected to compression. To examine these theories, we measured the strain at the external surface of the proximal lateral aspect of the femur of two female patients undergoing surgery for "snapping hip syndrome." During the surgical procedure, a strain-gauge rosette was bonded to the lateral aspect of the femur and the cortical strains were monitored while the patient performed a series of activities. In both patients, principle tensile strain increased significantly during one-legged stance, walking, and stair climbing as compared with that during two-legged stance. During each loading situation, the principal tensile strain was aligned within 22 degrees to the longitudinal femoral axis. Dynamic strain measurements consistently revealed tensile axial strain at the lateral aspect of the femur during each activity. The present study supports the classic bending theory of Pauwels and demonstrates that the proximal lateral aspect of the femur is subjected to tension during the stance phase of gait.
Hydroxyapatite-coated standard anatomical and customised femoral stems are designed to transmit load to the metaphyseal part of the proximal femur in order to avoid stress shielding and to reduce resorption of bone. In a randomised in vitro study, we compared the changes in the pattern of cortical strain after the insertion of hydroxyapatite-coated standard anatomical and customised stems in 12 pairs of human cadaver femora. A hip simulator reproduced the physiological loads on the proximal femur in single-leg stance and stair-climbing. The cortical strains were measured before and after the insertion of the stems. Significantly higher strain shielding was seen in Gruen zones 7, 6, 5, 3 and 2 after the insertion of the anatomical stem compared with the customised stem. For the anatomical stem, the hoop strains on the femur also indicated that the load was transferred to the cortical bone at the lower metaphyseal or upper diaphyseal part of the proximal femur. The customised stem induced a strain pattern more similar to that of the intact femur than the standard, anatomical stem.
The results were comparable in most respects. Unprotected weight-bearing was achieved earlier after IM nailing. Anterior knee pain was frequent after nailing.
This randomized study was performed to compare wear and migration of five different cemented total hip joint articulations in 150 patients. The patients received either a Charnley femoral stem with a 22.2 mm head or a Spectron EF femoral stem with a 28 mm head. The Charnley articulated with a g-sterilized Charnley Ogee acetabular cup. The Spectron EF was used with either EtOsterilized non-cross-linked polyethylene (Reflection All-Poly) or highly cross-linked (Reflection All-Poly XLPE) cups, combined with either cobalt chrome (CoCr) or Oxinium femoral heads. The patients were followed with repeated RSA measurements for 2 years. After 2 years, the EtO-sterilized non-cross-linked Reflection All-Poly cups had more than four times higher proximal penetration than its highly cross-linked counterpart. Use of Oxinium femoral heads did not affect penetration at 2 years compared to heads made of CoCr. Further follow-up is needed to evaluate the benefits, if any, of Oxinium femoral heads in the clinical setting. The Charnley Ogee was not outperformed by the more recently introduced implants in our study. We conclude that this prostheses still represents a standard against which new implants can be measured. Osteolysis induced by wear debris of ultra-high molecular weight polyethylene (UHMWPE) is considered the most common cause for failure of total hip arthroplasties (THA). 1 Sterilization technique and UHMWPE quality are related to wear. 2 Sterilization with gamma irradiation in air breaks the polymer chains and generates free radicals. Free radicals may combine with each other creating cross-links between adjacent molecules, which reduces abrasive wear. However, they entail the disadvantage of oxidative degradation of polyethylene (PE) when exposed to the body's oxidative environment, which may lead to deterioration of mechanical properties. 3 To address the problem, sterilization methods in inert environments with ethylene oxide (EtO) or gas plasma were introduced. However, these methods do not have the benefits of cross-linking, and an earlier report showed increase in early in vivo wear after EtO sterilization. 4 Highly cross-linked polyethylenes (HXLPE) provides a considerable reduction of wear compared to conventional polyethylene (PE). 5,6 The common denominator of HXLPEs is an increased cross-linking by high dosage irradiation, and the reduction of oxidative degradation by eliminating the free radicals through thermal stabilization. The Reflection XLPE liner (Smith & Nephew, Memphis, TN) used in cementless THA has shown promising results in vitro 7 and in vivo. 8 The cemented version of this implant is the Reflection All-Poly XLPE cup. To our knowledge, no clinical studies exist on this implant.Concerns of PE wear have also been addressed by introducing alternative femoral head materials. Oxidized zirconium (Oxinium, Smith & Nephew) was introduced in the last decade for use in THA. 7 Oxinium has a metal core and an approximately 5 mm thick zirconia ceramic surface. During the manufacturing process, heati...
We have compared the changes in the pattern of the principal strains in the proximal femur after insertion of eight uncemented anatomical stems and eight customised stems in human cadaver femora. During testing we aimed to reproduce the physiological loads on the proximal femur and to simulate single-leg stance and stair-climbing. The strains in the intact femora were measured and there were no significant differences in principal tensile and compressive strains in the left and right femora of each pair. The two types of femoral stem were then inserted randomly into the left or right femora and the cortical strains were again measured. Both induced significant stress shielding in the proximal part of the metaphysis, but the deviation from the physiological strains was most pronounced after insertion of the anatomical stems. The principal compressive strain at the calcar was reduced by 90% for the anatomical stems and 67% for the customised stems. Medially, at the level of the lesser trochanter, the corresponding figures were 59% and 21%. The anatomical stems induced more stress concentration on the anterior aspect of the femur than did the customised stems. They also increased the hoop strains in the proximomedial femur. Our study shows a consistently more physiological pattern of strain in the proximal femur after insertion of customised stems compared with standard, anatomical stems.
BackgroundHip fractures in older people are associated with high morbidity, mortality, disability and reduction in quality of life. Traditionally people with hip fracture are cared for in orthopaedic departments without additional geriatric assessment. However, studies of postoperative rehabilitation indicate improved efficiency of multidisciplinary geriatric rehabilitation as compared to traditional care. This randomized controlled trial (RCT) aims to investigate whether an additional comprehensive geriatric assessment of hip fracture patients in a special orthogeriatric unit during the acute in-hospital phase may improve outcomes as compared to treatment as usual in an orthopaedic unit.Methods/designThe intervention of interest, a comprehensive geriatric assessment is compared with traditional care in an orthopaedic ward. The study includes 401 home-dwelling older persons >70 years of age, previously able to walk 10 meters and now treated for hip fracture at St. Olav Hospital, Trondheim, Norway. The participants are enrolled and randomised during the stay in the Emergency Department. Primary outcome measure is mobility measured by the Short Physical Performance Battery (SPPB) at 4 months after surgery. Secondary outcomes measured at 1, 4 and 12 months postoperatively are place of residence, activities of daily living, balance and gait, falls and fear of falling, quality of life and depressive symptoms, as well as use of health care resources and survival.DiscussionWe believe that the design of the study, the randomisation procedure and outcome measurements will be of sufficient strength and quality to evaluate the impact of comprehensive geriatric assessment on mobility and other relevant outcomes in hip fracture patients.Trials registrationClinicalTrials.gov, NCT00667914
We have compared the changes in the pattern of the principal strains in the proximal femur after insertion of eight uncemented anatomical stems and eight customised stems in human cadaver femora. During testing we aimed to reproduce the physiological loads on the proximal femur and to simulate single-leg stance and stair-climbing.The strains in the intact femora were measured and there were no significant differences in principal tensile and compressive strains in the left and right femora of each pair. The two types of femoral stem were then inserted randomly into the left or right femora and the cortical strains were again measured. Both induced significant stress shielding in the proximal part of the metaphysis, but the deviation from the physiological strains was most pronounced after insertion of the anatomical stems.The principal compressive strain at the calcar was reduced by 90% for the anatomical stems and 67% for the customised stems. Medially, at the level of the lesser trochanter, the corresponding figures were 59% and 21%. The anatomical stems induced more stress concentration on the anterior aspect of the femur than did the customised stems. They also increased the hoop strains in the proximomedial femur. Our study shows a consistently more physiological pattern of strain in the proximal femur after insertion of customised stems compared with standard, anatomical stems. [Br] 2001;83-B:921-9. J Bone Joint Surg
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.