Pathologic complete response (pCR) is a predictor for favorable outcome after neoadjuvant treatment in early breast cancer. Modulation of gene expression may also provide early readouts of biological activity and prognosis, offering the possibility for timely response‐guided treatment adjustment. The role of early transcriptional changes in predicting response to neoadjuvant chemotherapy plus bevacizumab was investigated. One‐hundred‐and‐fifty patients with large, operable and locally advanced HER2‐negative breast cancer received epirubicin and docetaxel, with the addition of bevacizumab. Patients underwent tumor biopsies at baseline, after Cycle 2 and at the time of surgery. The primary end point, pCR, and its relation with the secondary endpoints event‐free survival (EFS), overall survival (OS) and gene expression profiles, are reported. The pCR rate was 13% (95% CI 8.6–20.2), with significantly more pCRs among triple‐negative [28% (95% CI 14.8–45.4)] than among hormone receptor positive (HR+) tumors [9% (95% CI 4.6–16.3); (OR = 3.9 [CI = 1.5–10.3])]. pCR rates were not associated with EFS or OS. PAM50 subtypes significantly changed after Cycle 2 (p = 0.03) and an index of absolute changes in PAM50 correlations between these time‐points was associated with EFS [HR = 0.62 (CI = 0.3–1.1)]. In univariable analyses, signatures for angiogenesis, proliferation, estrogen receptor signaling, invasion and metastasis, and immune response, measured after Cycle 2, were associated with pCR in HR+ tumors. Evaluation of changes in molecular subtypes and other signatures early in the course of neoadjuvant treatment may be predictive of pCR and EFS. These factors may help guide further treatment and should be considered when designing neoadjuvant trials.
Background Contrast-enhanced ultrasound (CEUS) has gained interest because of its ability to gather vascular information in diverse organs. There is still a subject of debate concerning its value in breast lesions, especially as a differential diagnostic tool. Purpose To investigate whether kinetic parameters of CEUS can differentiate between malignant and benign breast lesions. Material and Methods We evaluated 75 malignant and 21 benign lesions in the breast or axilla. Contrast harmonic imaging (CHI) US was performed after the injection of a bolus dose of 2.4 mL of Sono Vue® (Bracco, Milano, Italy). The following parameters were calculated for kinetic analysis: initial slope, time to peak enhancement, wash-out ratios W21 and W50 (relative decrease in signal intensity from the peak enhancement to 21 s and 50 s, respectively). Results A significant difference was found between the benign and malignant lesions in time-to-peak ( P value <0.05) and wash-out ratios W21 ( P value <0.001) and W50 ( P value <0.001). The mean time-to-peak was 9.3 s for malignant and 14.6 s for benign lesions. The mean signal drop from peak to signal intensity measured at 50 s was 85% for malignant and 66% for benign lesions. There was no difference in absolute values of peak signal intensity and initial slope. The most significant difference between standardized benign and malignant wash-out curves was found at 21 s but statistical significance was reached in the range of 14–50 s. Conclusion Real-time CEUS can evolve into a new non-invasive option for differentiate malignant from benign breast lesions.
Background One of the big challenges in onco-radiology is to find a reliable imaging method that may predict early response during the first cycles of any neoadjuvant chemotherapy. Purpose To evaluate the use of real-time harmonic contrast-enhanced ultrasound (CEUS) in predicting early response in breast cancer tumors under neoadjuvant chemotherapy (NAC) treatment. Material and Methods Nineteen consecutive patients with invasive breast cancer were evaluated with a bolus dose of 2.4 mL contrast agent using CEUS, before and after two cycles of epirubicin and docetaxel. The lognormal function was used for quantitative analysis of kinetic data to evaluate early response. Results There was statistically significant difference in time-to-peak ( t) between responders and non-responders (two sample t-test, P = 0.027) where t was significantly longer at the week 5 than at the baseline scan among responders when compared to non-responders. Conclusion In-flow of intravascular contrast agent in tumors is significantly slower in responders at real-time harmonic CEUS, and might be effectively used for the evaluation of early response to chemotherapy in invasive breast cancer. However, further investigations in a larger and more heterogeneous population should be performed to corroborate the reliability of the method.
Invasive breast carcinomas exhibiting earlier peak enhancement and faster elimination of microbubble contrast agent at CEUS are found to be associated with established predictors of poor prognosis.
CEUS using real-time harmonic imaging in order to evaluate breast tumors should be performed with bolus administration of contrast agent in order to achieve better intensity/time curve outcomes.
The purpose of this study was to determine the safety and efficacy of percutaneous ultrasound (US) guided preferential radiofrequency ablation (PRFA) of unifocal human invasive breast carcinoma with largest radiological diameters of up to 16 mm. Thirty-three patients were enrolled in a study to be treated prior to scheduled partial mastectomy. A needle-shaped treatment electrode, successively developed in two different sizes, was placed into the center of the lesions using ultrasound guidance. A temperature of 85 degrees C was maintained for 10 min. The analysis of the resected specimen was performed using conventional histopathological methods with the aim to determine the size of the lesion as well as the potential viability of tumor cells. Of the 33 patients enrolled 31 were treated. In 26 (84%) patients a complete ablation of the tumor was achieved. Ultrasound guided preferential radiofrequency ablation of small breast carcinoma is feasible and patient friendly. The success rate depends on accurate preoperative diagnostic imaging as well as an exact position of the needle electrode.
Background Automated breast volume scanner (ABVS) is an ultrasound (US) device with a wide scanner that sweeps over a large area of the breast and the acquired transverse images are sent to a workstation for reconstruction and review. Whether ABVS is as reliable as handheld US is, however, still not established. Purpose To compare the sensitivity and specificity of ABVS to handheld breast US for detection of breast cancer, in the situation of recall after mammography screening. Material and Methods A total of 113 women, five with bilateral suspicious findings, undergoing handheld breast US due to a suspicious mammographic finding in screening, underwent additional ABVS. The methods were assessed for each breast and each detected lesion separately and classified into two categories: breasts with mammographic suspicion of malignancy and breasts with a negative mammogram. Results Twenty-six cancers were found in 25 women. In the category of breasts with a suspicious mammographic finding (n = 118), the sensitivity of both handheld US and ABVS was 88% (22/25). The specificity of handheld US was 93.5% (87/93) and ABVS was 89.2% (83/93). In the category of breasts with a negative mammography (n = 103), the sensitivity of handheld US and ABVS was 100% (1/1). The specificity of handheld US was 100% (102/102) and ABVS was 94.1% (96/102). Conclusion ABVS can potentially replace handheld US in the investigation of women recalled from mammography screening due to a suspicious finding. Due to the small size of our study population, further investigation with larger study populations is necessary before the implementation of such practice.
The optimal way to evaluate kinetic features of invasive breast tumors using real-time CEUS is with an injection of contrast agent of either 2.4 mL or 4.8 mL.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.