Control of blood glucose (BG) in an acceptable range is a major therapy target for diabetes patients in both the hospital and outpatient environments. This review focuses on the state of point-of-care (POC) glucose monitoring and the accuracy of the measurement devices. The accuracy of the POC glucose monitor depends on device methodology and other factors, including sample source and collection and patient characteristics. Patient parameters capable of influencing measurements include variations in pH, blood oxygen, hematocrit, changes in microcirculation, and vasopressor therapy. These elements alone or when combined can significantly impact BG measurement accuracy with POC glucose monitoring devices (POCGMDs). In general, currently available POCGMDs exhibit the greatest accuracy within the range of physiological glucose levels but become less reliable at the lower and higher ranges of BG levels. This issue raises serious safety concerns and the importance of understanding the limitations of POCGMDs. This review will discuss potential interferences and shortcomings of the current POCGMDs and stress when these may impact the reliability of POCGMDs for clinical decision-making.
The clinical utility of cross-linked tetrameric hemoglobin solutions is limited by peripheral vasoconstriction thought to be due to scavenging of nitric oxide. In addition, transfusion of crude preparations of hemoglobin polymers can cause arterial hypertension. We tested the hypothesis that eliminating low-molecular-weight components from the polymer solution would prevent extravasation and its associated pressor response. A zero-link polymer of bovine hemoglobin was developed without chemical linkers left between the tetramers. Transfusion of unprocessed preparations of these polymers in rats resulted in appearance of the polymer in the renal hilar lymph. However, eliminating the low-molecular-weight components with a 300-kDa diafiltration resulted in an average hydrodynamic radius of 250 A and in undetectable levels of polymer in hilar lymph. Exchange transfusion in anesthetized rats and cats and in awake cats produced no increase in arterial pressure. In anesthetized cats, exchange transfusion with an albumin solution reduced hematocrit from 30 to 18%, increased cerebral blood flow, and dilated pial arterioles. In contrast, reducing hematocrit by transfusing the diafiltered polymer did not increase cerebral blood flow as pial arterioles constricted. These results are consistent with the hypothesis that the increase in arterial pressure associated with cell-free hemoglobin transfusion depends on hemoglobin extravasation. Constriction observed in the cerebrovascular bed with a nonextravasating hemoglobin polymer at low hematocrit is presumably a regulatory response to prevent overoxygenation at low blood viscosity.
Mean and local cerebral blood flows were lower during sevoflurane than during isoflurane anesthesia. This difference cannot be explained by differing changes in glucose utilization because glucose utilization was decreased to the same extent in both groups.
The effect of transfusing a nonextravasating, zero-link polymer of cell-free hemoglobin on pial arteriolar diameter, cerebral blood flow (CBF), and O2 transport (CBF x arterial O2 content) was compared with that of transfusing an albumin solution at equivalent reductions in hematocrit (approximately 19%) in anesthetized cats. The influence of viscosity was assessed by coinfusion of a high-viscosity solution of polyvinylpyrrolidone (PVP), which increased plasma viscosity two- to threefold. Exchange transfusion of a 5% albumin solution resulted in pial arteriolar dilation, increased CBF, and unchanged O2 transport, whereas there were no significant changes over time in a control group. Exchange transfusion of a 12% polymeric hemoglobin solution resulted in pial arteriolar constriction and unchanged CBF and O2 transport. Coinfusion of PVP with albumin produced pial arteriolar dilation that was similar to that obtained with transfusion of albumin alone. In contrast, coinfusion of PVP with hemoglobin converted the constrictor response to a dilator response that prevented a decrease in CBF. Pial arteriolar dilation to hypercapnia was unimpaired in groups transfused with albumin or hemoglobin alone but was attenuated in the largest vessels in albumin and hemoglobin groups coinfused with PVP. Unexpectedly, hypocapnic vasoconstriction was blunted in all groups after transfusion of albumin or hemoglobin alone or with PVP. We conclude that 1) the increase in arteriolar diameter after albumin transfusion represents a compensatory response that prevents decreased O2 transport at reduced O2-carrying capacity, 2) the decrease in diameter associated with near-normal O2-carrying capacity after cell-free polymeric hemoglobin transfusion represents a compensatory mechanism that prevents increased O2 transport at reduced blood viscosity, 3) pial arterioles are capable of dilating to an increase in plasma viscosity when hemoglobin is present in the plasma, 4) decreasing hematocrit does not impair pial arteriolar dilation to hypercapnia unless plasma viscosity is increased, and 5) pial arteriolar constriction to hypocapnia is impaired at reduced hematocrit independently of O2-carrying capacity.
Inhibition of glutamine synthesis reduces astrocyte swelling and associated physiological abnormalities during acute ammonium acetate infusion in anesthetized rats. We tested the hypothesis that inhibition of glutamine accumulation during more prolonged ammonium acetate infusion in unanesthetized rats reduces cortical astrocyte swelling and immunohistochemical changes in astrocytic proteins. Rats received a continuous i.v. infusion of either sodium acetate or ammonium acetate for 24 h to increase plasma ammonia from about 30-400 μmol/l. Cohorts were pretreated with vehicle or L-methionine-S-sulfoximine (MSO; 0.83 mmol/kg). MSO reduced glutamine synthetase activity by 57% and glutamine synthetase immunopositive cell number by 69%, and attenuated cortical glutamine accumulation by 71%. Hyperammonemia increased the number of swollen astrocytes in cortex and MSO reduced this increase to control values. The number of glial fibrillary acidic protein immunopositive cells in cortex was greater in hyperammonemic rats and the increase in superficial cortical layers was attenuated by MSO. Immunoreactivity for the gap junction protein connexin-43 in the neuropil, assessed by optical density, was greater in the hyperammonemic group compared with controls, but this increase was not attenuated by MSO. No changes in the optical density of GLT1 glutamate transporter immunoreactivity in cortex were detected in any group. We conclude that glutamine synthetase inhibition reduces astrocyte swelling and ameliorates some of the reactive astroglial cytoskeletal alterations seen at 24 h of hyperammonemia, but that gap junction changes in astrocytes occur independently of glutamine accumulation and swelling. Keywords ammonia; astrocyte; connexin; cerebral edema; glial fibrillary acidic protein; glutamine Astrocyte swelling is a distinctive feature of the histological finding in humans who die from severe liver disease or urea cycle disorders. Experimental models of liver dysfunction and hyperammonemia are also marked by watery swelling of astrocytes and cellular hypertrophy of astrocyte cell bodies without necessarily presenting with overt neuronal pathology. Thus, hyperammonemia is considered to be a major factor contributing to the cellular changes seen in severe hepatic encephalopathy (Norenberg, 1998 Tracer studies reveal that blood-borne ammonia is rapidly incorporated into brain glutamine, and that this process is markedly slowed in vivo by inhibiting glutamine synthetase (GS) with methionine sulfoximine (MSO), thereby disrupting compartmentation of nitrogen metabolism (Cooper et al., 1979). Based on the observations 1) that increased brain glutamine concentration is one of the most consistent biochemical change seen both clinically and experimentally with liver disease, urea cycle disorders or pure hyperammonemia (Cooper, 2001), and 2) that GS is enriched in astrocytes (Norenberg and Martinez-Hernandez, 1979), we postulated that glutamine accumulated in astrocytes may act as an osmolyte that contributes to astrocyte swelli...
SUMMARYEach organ possesses specific properties for controlling microvascular perfusion. Such specificity provides an opportunity to design transfusion fluids that target thrombo-embolic or vasospasminduced ischemia in a particular organ or that optimize overall perfusion from systemic shock. The role of viscosity in the design of these fluids might be underestimated, because viscosity is rarely monitored or considered in critical care decisions. Studies linking viscosity-dependent changes of microvascular perfusion to outcome-relevant data suggest that whole blood viscosity is negligible as a determinant of microvascular perfusion under physiological conditions when autoregulation is effective. Because autoregulation is driven to maintain oxygen supply constant, the organism will compensate for changes in blood viscosity to sustain oxygen delivery. In contrast, under pathological conditions in the brain and elsewhere, increases of overall viscosity should be avoided -including all the situations where vascular autoregulatory mechanisms are inoperative due to ischemia, structural damage or physiologic dysfunction. As latter conditions are not to identify with high certainty, the risks that accompany therapeutic correction of blood viscosity are outweighing the benefits. The ability to bedside monitor blood viscosity and to link changes in viscosity to outcome parameters in various clinical conditions would provide more solid foundation for evidence-based clinical management.
Residency programs are charged with teaching, assessing, and documenting resident competency for a multitude of skills throughout the course of residency training. An innovative, competition-based objective structured clinical examination event was designed in our department to objectively assess the skill level of anesthesiology residents. After conducting the identical event for 2 years in postgraduate year 1 (PGY1) and postgraduate year 2 (PGY2) residents, we tested the hypothesis that the event can provide adequate standardization to appropriately document progression in technical and nontechnical skills. Twenty-one residents participated in both events during their PGY1 and PGY2 years: n = 10, 2012/2013, n = 11, 2013/2014. The PGY1 participants in 2012 were retested in 2013 (as PGY2 residents) during an identical event, and their performance was compared as a group and on an individual level. The PGY1 residents in 2013 did the same in 2014. Four workstations were analyzed to determine whether improvement in performance occurred between the PGY1 and the PGY2 years: (1) preoperative assessment, (2) operating room anesthesia station checkout, (3) peripheral IV and endotracheal tube placement, and (4) transfer of care in the postanesthesia care unit. The performances of PGY1 and PGY2 residents were compared. The assessments were performed by anesthesiology faculty using checklists, time to complete task, and Likert scale ratings. Data analysis showed improved technical anesthesia skills (operating room setup, peripheral IV, and endotracheal tube placement) and more complete anesthesia-related information management in the preoperative assessment and postoperative transition of care in the postanesthesia care unit in PGY2 residents compared with the PGY1 performance of the same residents. The described event is a valuable tool for objective assessment of multiple anesthesia skills and possible milestones during residency.
Differences in the physicochemical properties of desflurane compared with isoflurane are not associated with major differences in the effects of both volatile anesthetics on cerebral glucose utilization, blood flow, and the coupling between LCBF and LCGU.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.