Fluorescence-enhanced diffuse optical tomography is expected to be useful to the collection of functional information from small animal models. This technique is currently limited by the extent of tissue heterogeneity and management of the shape of the animals. We propose an approach based on the reconstruction of object heterogeneity, which provides an original solution to the two problems. Three evaluation campaigns are described: the first two were performed on phantoms designed to test the reconstructions in highly heterogeneous media and noncontact geometries; the third was conducted on mice with lung tumors to test fluorescence yield reconstruction feasibility in vivo.
This work is dedicated to the reduction of reconstruction artefacts due to motion occurring during the acquisition of computerized tomographic projections. This problem has to be solved when imaging moving organs such as the lungs or the heart. The proposed method belongs to the class of motion compensation algorithms, where the model of motion is included in the reconstruction formula. We address two fundamental questions. First what conditions on the deformation are required for the reconstruction of the object from projections acquired sequentially during the deformation, and second how do we reconstruct the object from those projections. Here we answer these questions in the particular case of 2D general time-dependent affine deformations, assuming the motion parameters are known. We treat the problem of admissibility conditions on the deformation in the parallel-beam and fan-beam cases. Then we propose exact reconstruction methods based on rebinning or sequential FBP formulae for each of these geometries and present reconstructed images obtained with the fan-beam algorithm on simulated data.
We present in vivo experiments conducted with a new fluorescence diffuse optical tomographic (fDOT) system on cancerous mice bearing mammary murine tumors. We first briefly present this new system that has been developed and its associated reconstruction method. Its main specificity is its ability to reconstruct the fluorescence yield even in heterogeneous and highly attenuating body regions such as lungs and to enable mouse inspection without immersion in optical index matching liquid (Intralipid and ink). Some phantom experiments validate the performance of this new system for heterogeneous media inspection. Its use for a mice study is then related. It consists in the follow-up of the lungs at different stages of tumor development after injection of RAFT-(cRGD)4-Alexa700. As expected, the reconstructed fluorescence increases along with the tumor stage. These results validate the use of our system for biological studies of small animals.
Abstract:We present the first experimental results of reflectance Diffuse Optical Tomography (DOT) performed with a fast-gated single-photon avalanche diode (SPAD) coupled to a time-correlated single-photon counting system. The Mellin-Laplace transform was employed to process time-resolved data. We compare the performances of the SPAD operated in the gated mode vs. the non-gated mode for the detection and localization of an absorbing inclusion deeply embedded in a turbid medium for 5 and 15 mm interfiber distances. We demonstrate that, for a given acquisition time, the gated mode enables the detection and better localization of deeper absorbing inclusions than the non-gated mode. These results obtained on phantoms demonstrate the efficacy of time-resolved DOT at small interfiber distances. By achieving depth sensitivity with limited acquisition times, the gated mode increases the relevance of reflectance DOT at small interfiber distance for clinical applications.
Dynamic cone-beam reconstruction algorithms are required to reconstruct three-dimensional (3D) image sequences on dynamic 3D CT combining multi-row two-dimensional (2D) detectors and sub-second scanners. The speed-up of the rotating gantry allows one to improve the temporal resolution of the image sequence, but at the same time, it implies increase in the dose delivered during a given time period to keep constant the signal-to-noise ratio associated with each frame. The alternative solution proposed in this paper is to process data acquisition on several half-turns in order to reduce the dose delivered per rotation with the same signal-to-noise ratio. In order to compensate for time evolution and motion artefacts, we propose to use a dynamic particle model to describe the object evolution during the scan. In this article, we first introduce the dynamic particle model and the dynamic CT acquisition model. Then, we explain the principle of the proposed dynamic cone-beam reconstruction algorithm. Lastly, we present preliminary results on simulated data.
We show how to apply the Mellin-Laplace transform to process time-resolved reflectance measurements for diffuse optical tomography. We illustrate this method on simulated signals incorporating the main sources of experimental noise and suggest how to fine-tune the method in order to detect the deepest absorbing inclusions and optimize their localization in depth, depending on the dynamic range of the measurement. To finish, we apply this method to measurements acquired with a setup including a femtosecond laser, photomultipliers and a time-correlated single photon counting board. Simulations and experiments are illustrated for a probe featuring the interfiber distance of 1.5 cm and show the potential of time-resolved techniques for imaging absorption contrast in depth with this geometry.
Diffuse optical tomography for medical applications can require probes with small dimensions involving short source-detector separations. Even though this configuration is seen at first as a constraint due to the challenge of depth sensitivity, we show here that it can potentially be an asset for spatial resolution in depth. By comparing two fiber optic probes on a test object, we first show with simulations that short source-detector separations improve the spatial resolution down to a limit depth. We then confirm these results in an experimental study with a state-of-the-art setup involving a fast-gated single-photon avalanche diode allowing maximum depth sensitivity. We conclude that short source-detector separations are an option to consider for the design of probes so as to improve image quality for diffuse optical tomography in reflectance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.