P Pu ur rp po os se e: : To evaluate the risk of retrograde embolization of flush solution in neonates and infants with routinely used electronic syringe pumps and infusion bag pump flush systems.
Saline tonometry has been replaced by automated air tonometry (TONOCAP ® ). As with saline tonometry there are some pitfalls to consider. We investigated the influence of different filling handicaps to the tonometry catheter sampling balloon on measurement of regional PCO 2 (PrCO 2 ). In an in vitro set-up, PrCO 2 was measured using the TONOCAP ® at intervals of 10 minutes from a 8F tonometry catheter sampling balloon placed in a container with constant PCO 2 (PcCO 2 ). Catheter alarms displayed by the TONOCAP® device were noted. The following experiments were performed: A) control measurement without modifications; B) adding deadspace of 7 ml into the sampling line; C) placing the sampling balloon in a 3 ml syringe; D) cross-clamping of the sampling balloon. Each experiment was performed four times using two catheters on two TONOCAP ® devices. Differences between PcCO 2 and PrCO 2 were calculated as Pc-rCO 2. Results are presented as mean±SD and were compared using ANOVA with Scheffe's correction. Pc-rCO 2 in the control set-up (A) amounted to 0.16±0.22%. Increasing catheter deadspace (B) resulted in a higher Pc-rCO 2 of 3.2±0.57% (P<0.0001). Restriction of balloon expansion (C) caused an Pc-rCO 2 gap of 1.17±0.36% (P<0.0001). With filling restriction (D) the Pc-rCO 2 gap increased to 3.87±0.29% (P<0.0001). The catheter alarms provided were not able to indicate all catheter problems and initial alarms disappeared although the problems continued. We conclude that impaired catheter deadspace to balloon volume relation can negatively influence accuracy of PrCO 2 measurement by the TONOCAP ®.
Infusion solutions can be significantly warmed by syringe pumps. This has potential impact on bacterial growth and the stability of drug solutions and blood products infused, as well as on the susceptibility to hydrostatic pressure changes within the infusion syringe.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.