The power spectrum of heart rate variability contains low frequency (LF = 0.08-0.12 Hz) and high frequency (HF = 0.18-0.30 Hz) components said to represent neurocardiac rhythms. To verify whether such a relationship exists we report a unique study where the heart rate autospectrum was determined in a 28-year-old epileptic male patient with an implanted vagal electrical stimulator. The stimulator was activated at 20 Hz, 300 microseconds pulse, and 1.25 V. Continuous ECG and respiratory waveform records were obtained over 45 minutes every 8 hours (7-8 AM; 3-4 PM; 11-12 PM) with the stimulator ON, then 24 hours OFF and then 24 hours ON again. The overall LF:HF peak ratio increased from 0.64 to 1.99 (P less than 0.001) after the stimulator was turned OFF. There was a dramatic increase in the LF peak power (greater than 60%) and a corresponding decrease in the HF peak power (greater than 65%) when the stimulator was turned OFF. These values were reversed when the stimulator was turned ON again. In the early morning and late evening hours, there was a significant rightward shift in the LF peak power frequency (average 0.057 to 0.075 Hz) whenever the stimulator was ON. Otherwise, there were no significant circadian variations in any of the autospectral components. The results demonstrate an unequivocal relationship between selective vagal nerve electrostimulation and alterations in the heart rate autospectrum.
(1) A relationship exists between selective vagal nerve electrostimulation and the HRA; and (2) high stimulation frequency of the vagus nerve in man is associated with sustained augmentation of cardiac vagal tone throughout a 24-hour cycle.
suMMARY Baclofen was given intrathecally to six patients with severe lower limb spasticity due to traumatic spinal cord injury. The effects of the drug on spasticity and the ratio between the maximum amplitude of the H reflex and the M response from the soleus (Hmax/Mmax ratio) were assessed. In each patient, spasticity was reduced following intrathecal baclofen and in four patients there was a reduction in the amplitude of the H reflex and Hmax/Mmax ratio. These results suggest that the Hmax/Mmax ratio may be helpful in establishing optimum drug dosage, particularly when the drug is used on a chronic basis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.