The global COVID-19 pandemic has led to a worldwide shortage of ventilators. This shortage has initiated discussions on how to support multiple patients with a single ventilator (ventilator splitting). Ventilator splitting is incompletely tested, experimental and the effects have not been fully characterised. This study investigated the effect of ventilator splitting on system variables (inspiratory pressure, flow and volume) and the possibility of different ventilation targets for each limb using only standard hospital equipment. Experiments were conducted on two test lungs with different compliances (0.02 l.cmH 2 O À1 and 0.04 l.cmH 2 O À1 ). The ventilator was used in both pressure and volume control modes and was set to ventilate the low compliance lungs at end-tidal volumes of 500 AE 20 ml. A flow restrictor apparatus consisting of a Hoffman clamp and tracheal tube was connected in series to the inspiratory limb of the high compliance test lungs and the resistance modified to achieve end-tidal volumes of 500 AE 20 ml. The restriction apparatus successfully modified the inspiratory pressure, minute ventilation and volume delivered to the high compliance test lungs in both pressure control (27.3-17.8 cmH 2 O, 15.2-8.0 l.min À1 and 980-499 ml, respectively) and volume control (21.0-16.7 cmH 2 O, 10.7-7.9 l.min À1 and 659-498 ml, respectively) ventilation modes. Ventilator splitting is not condoned by the authors. However, these experiments demonstrate the capacity to simultaneously ventilate two test lungs of different compliances, and using only standard hospital equipment, modify the delivered pressure, flow and volume in each test lung.
Rotary ventricular assist devices (VADs) are used to provide mechanical circulatory support. However, their lack of preload sensitivity in constant speed control mode (CSC) may result in ventricular suction or venous congestion. This is particularly true of biventricular support, where the native flow-balancing Starling response of both ventricles is diminished. It is possible to model the Starling response of the ventricles using cardiac output and venous return curves. With this model, we can create a Starling-like physiological controller (SLC) for VADs which can automatically balance cardiac output in the presence of perturbations to the circulation. The comparison between CSC and SLC of dual HeartWare HVADs using a mock circulation loop to simulate biventricular heart failure has been reported. Four changes in cardiovascular state were simulated to test the controller, including a 700 mL reduction in circulating fluid volume, a total loss of left and right ventricular contractility, reduction in systemic vascular resistance ( SVR) from 1300 to 600 dyne s/cm5, and an elevation in pulmonary vascular resistance ( PVR) from 100 to 300 dyne s/cm5. SLC maintained the left and right ventricular volumes between 69-214 mL and 29-182 mL, respectively, for all tests, preventing ventricular suction (ventricular volume = 0 mL) and venous congestion (atrial pressures > 20 mm Hg). Cardiac output was maintained at sufficient levels by the SLC, with systemic and pulmonary flow rates maintained above 3.14 L/min for all tests. With the CSC, left ventricular suction occurred during reductions in SVR, elevations in PVR, and reduction in circulating fluid simulations. These results demonstrate a need for a physiological control system and provide adequate in vitro validation of the immediate response of a SLC for biventricular support.
Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only a systemic circulation with no autoregulatory responses and limited validation. This study aimed to develop, and validate against human data, an advanced MCL with systemic, pulmonary, cerebral, and coronary circulations with autoregulatory responses. The biventricular MCL was constructed with pneumatically controlled hydraulic circulations with Starling responsive ventricles and autoregulatory cerebral and coronary circulations. Hemodynamic repeatability was assessed and complemented by validation using impedance cardiography data from 50 healthy humans. The MCL successfully simulated patient scenarios including rest, exercise, and left heart failure with and without cardiovascular device support. End-systolic pressure-volume relationships for respective healthy and heart failure conditions had slopes of 1.27 and 0.54 mm Hg mL −1 (left ventricle), and 0.18 and 0.10 mm Hg mL −1 (right ventricle), aligning with the literature. Coronary and cerebral autoregulation showed a strong correlation (R 2 : .99) between theoretical and experimentally derived circuit flow. MCL repeatability was demonstrated with correlation coefficients being statistically significant (P < .05) for all simulated conditions while MCL hemodynamics aligned well with human data. This advanced MCL is a valuable tool for inexpensive and controlled evaluation of cardiovascular devices.
The high cost of ventricular assist devices results in poor cost‐effectiveness when used as a short‐term bridging solution, thus a low‐cost alternative is desirable. The present study aimed to develop an intraventricular balloon pump (IVBP) for short‐term circulatory support, and to evaluate the effect of balloon actuation timing on the degree of cardiac support provided to a simulated in vitro severe heart failure (SHF) patient. A silicone IVBP was designed to avoid contact with internal left ventricular (LV) features (ie, papillary muscles, chordae, aortic, and mitral valves) based on LV computed tomography data of 10 SHF patients with dilated cardiomyopathy. The hemodynamic effects of varying balloon inflation and deflation timing parameters (inflation duty [D] and end‐inflation point [σ]) were evaluated in a purpose‐built systemic mock circulatory loop. Three IVBP actuation timing categories were defined: co‐, transitional, and counterpulsation. Compared to the SHF baseline, co‐pulsation increased aortic flow from 3.5 to 5.2 L/min, mean arterial pressure from 72.1 to 94.8 mmHg and ejection fraction from 14.4% to 21.5%, while mean left atrial pressure decreased from 14.6 to 10 mmHg. Transitional and counterpulsation resulted in a double ventricular pulse and extended the duration of increased ventricular pressure, potentially impeding diastolic filling and coronary perfusion. This in vitro study showed the IVBP could restore the hemodynamic balance of a simulated SHF patient with dilated cardiomyopathy to healthy levels.
Left ventricular (LV) distention and pulmonary congestion are major complications inherent to venoarterial extracorporeal membrane oxygenation (ECMO). This study aimed to quantitatively compare the hemodynamic differences between common circulatory unloading methods for ECMO. Ten circulatory unloading techniques were evaluated on a mock circulatory loop simulating acute LV failure supported by ECMO. Simulated unloading techniques included: surgical and percutaneous pulmonary artery (PA) venting, surgical left atrial venting, surgical and percutaneous LV venting, atrial septal defect, partial support ventricular assist device, intraaortic balloon pump, and temporary VAD with inline oxygenator (tVAD). The most LV unloading occurred with the surgically placed LV vent and tVAD, which reduced LV end-diastolic volume from 295 to 167 ml and 82 ml, respectively. Meanwhile, the PA surgical vent was the most effective at reducing mean PA pressure from 21.0 to 10.6 mm Hg, and the tVAD was most effective at reducing left atrial pressure from 13.3 to 4.4 mm Hg. The major limitation of this study was the use of a mock circulatory loop, which simulated lower left atrial pressure than is typically seen clinically. This study identified clinically significant hemodynamic variability between the different circulatory unloading techniques evaluated. However, the applicability of these techniques will vary with different patient disease etiology. Further studies on ECMO unloading will help to quantify hemodynamic benefits and establish treatment guidelines.
No abstract
Rotary ventricular assist devices (VADs) are less sensitive to preload than the healthy heart, resulting in inadequate flow regulation in response to changes in patient cardiac demand. Starling-like physiological controllers (SLCs) have been developed to automatically regulate VAD flow based on ventricular preload. An SLC consists of a cardiac response curve (CRC) which imposes a nonlinear relationship between VAD flow and ventricular preload, and a venous return line (VRL) which determines the return path of the controller. This study investigates the importance of a physiological VRL in SLC of dual rotary blood pumps for biventricular support. Two experiments were conducted on a physical mock circulation loop (MCL); the first compared an SLC with an angled physiological VRL (SLC-P) against an SLC with a vertical VRL (SLC-V). The second experiment quantified the benefit of a dynamic VRL, represented by a series of specific VRLs, which could adapt to different circulatory states including changes in pulmonary (PVR) and systemic (SVR) vascular resistance versus a fixed physiological VRL which was calculated at rest. In both sets of experiments, the transient controller responses were evaluated through reductions in preload caused by the removal of fluid from the MCL. The SLC-P produced no overshoot or oscillations following step changes in preload, whereas SLC-V produced 0.4 L/min (12.5%) overshoot for both left and right VADs. Additionally, the SLC-V had increased settling time and reduced controller stability as evidenced by transient controller oscillations. The transient results comparing the specific and standard VRLs demonstrated that specific VRL rise times were improved by between 1.2 and 4.7 s ( = 3.05 s), while specific VRL settling times were improved by between 2.8 and 16.1 seconds ( = 8.38 s) over the standard VRL. This suggests only a minor improvement in controller response time from a dynamic VRL compared to the fixed VRL. These results indicate that the use of a fixed physiologically representative VRL is adequate over a wide variety of physiological conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.