This paper describes a method of direct sampling of fine urban aerosol using porous carbon films, to increase collection efficiency and retain the structural integrity of the aerosol. A nuclepore membrane filter was coated with carbon and washed with chloroform to leave a clean porous carbon film on a 200‐mesh transmission electron microscope copper grid. The grid was attached to a clean nuclepore filter using carbon cement. Sampling was conducted for 1 h at 1.9 L min−1 flow rate. The porous carbon grid with sample was then assayed using transmission electron microscopy, and negatives were suitable for image analysis. The collection of fine airborne particles using this method is appropriate for electron microscopy, with a minimum of interference to the structure of collected particles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.