Aim: To evaluate treatment options after surgical revision of adjustable transobturator male system (ATOMS) and the results of further incontinence implantation. Materials and Methods: A retrospective multicenter study evaluating patients with surgical revision of ATOMS in academic institutions. Causes and factors affecting revision-free interval were studied and also the frequency of device explant and placement of second ATOMS or artificial urinary sphincter (AUS) at surgeon discretion. Operative results, complications (Clavien-Dindo), and efficacy (postoperative pad-test, pad-count, patient satisfaction, and patient global impression of improvement [PGI-I scale]) of each treatment option were compared. Results: Seventy-eight out of 902 patients (8.65%) with ATOMS underwent surgical revision at 4.1 ± 2.4 years mean follow-up and 75 (8.3%) were explanted. The main causes for revision included persistence of incontinence (35.9%) and scrotal port erosion (34.6%). Independent risk factors of the shortened revision-free interval were previous anti-incontinence surgery (HR, 1.83; 95% CI, 1.06-3.16; p = 0.007) and port erosion (HR, 1.83; 95% CI, 1.06-3.16; p = 0.0027). Fifty-eight (6.4%) received a second implant: 31 repeated ATOMS and 27 AUS. Operative time was longer for AUS (p = .003). The visual analog scale of pain at hospital discharge (p = 0.837) and postoperative complications (p = 0.154) were equivalent. The predominant cuff size for AUS was 4.5 cm (59.3%). Mean follow-up after the second implant was 29.1 ± 25.8 months. Postoperative efficacy of secondary treatment results favored ATOMS based on pad-test (p = 0.016), pad-count (p = 0.029), patient satisfaction (p = 0.04), and PGI-I (p = 0.025). Conclusions: ATOMS surgical revision due to different reasons generally leads to device explant. Rescue treatment is possible with ATOMS or AUS. No difference in postoperative complications was detected between secondary devices, but efficacy favors repeating ATOMS implantation.
Bladder dysfunction is characterized by urgency, frequency (pollakisuria, nocturia), and dysuria and may lead to urinary incontinence. Most of these symptoms can be attributed to disturbed bladder sensitivity. There is growing evidence that, besides the urothelium, suburothelial interstitial cells (suICs) are involved in bladder afferent signal processing. The massive expansion of the bladder during the filling phase implicates mechanical stress delivered to the whole bladder wall. Little is known about the reaction of suICs upon mechanical stress. Therefore, we investigated the effects of mechanical stimulation in cultured human suICs. We used fura-2 calcium imaging as a major physiological readout. We found spontaneous intracellular calcium activity in 75 % of the cultured suICs. Defined local pressure application via a glass micropipette led to local increased calcium activity in all stimulated suICs, spreading over the whole cell. A total of 51% of the neighboring cells in a radius of up to 100 µm from the stimulated cell showed an increased activity. Hypotonic ringer and shear stress also induced calcium transients. We found an 18-times increase in syncytial activity compared to unstimulated controls, resulting in an amplification of the primary calcium signal elicited in single cells by 50%. Our results speak in favor of a high sensitivity of suICs for mechanical stress and support the view of a functional syncytium between suICs, which can amplify and distribute local stimuli. Previous studies of connexin expression in the human bladder suggest that this mechanism could also be relevant in normal and pathological function of the bladder in vivo.
In this review, we focused on putatively interesting biomarkers of interstitial cystitis/bladder pain syndrome (IC/BPS) in relation to the etiopathology of this disease. Since its etiopathology is still under discussion, the development of novel biomarkers is critical for the correct classification of the patients in order to open personalized treatment options, on the one hand, and to separate true IC/BPS from the numerous confusable diseases with comparable symptom spectra on the other hand. There is growing evidence supporting the notion that the classical or Hunner-type IC (HIC) and the non-Hunner-type IC (NHIC) are different diseases with different etiopathologies and different pathophysiology at the full-blown state. While genetic alterations indicate close relationship to allergic and autoimmune diseases, at present, the genetic origin of IC/BPS could be identified. Disturbed angiogenesis and impairment of the microvessels could be linked to altered humoral signaling cascades leading to enhanced VEGF levels which in turn could enhance leucocyte and mast cell invasion. Recurrent or chronic urinary tract infection has been speculated to promote IC/BPS. New findings show that occult virus infections occurred in most IC/BPS patients and that the urinary microbiome was altered, supporting the hypothesis of infections as major players in IC/BPS. Environmental and nutritional factors may also influence IC/BPS, at least at a late state (e.g., cigarette smoking can enhance IC/BPS symptoms). The damage of the urothelial barrier could possibly be the result of many different causality chains and mark the final state of IC/BPS, the causes of this development having been introduced years ago. We conclude that the etiopathology of IC/BPS is complex, involving regulatory mechanisms at various levels. However, using novel molecular biologic techniques promise more sophisticated analysis of this pathophysiological network, resulting in a constantly improvement of our understanding of IC/BPS and related diseases.
(1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0–1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I). We performed the Wilcoxon rank sum test, Fisher’s exact test, logistic regression, and multivariate analysis. (3) Results: The study included 88 patients from 9 centers with a mean age of 71.3 years. No Clavien–Dindo > II complications occurred within the first 3 months after ATOMS implantation. A total of 10 cases (9%) required revision in the ensuing clinical course. After a mean follow-up of 42.5 months, 76.1% achieved social continence, and 56.8% used no pads at all. Mean urine leakage/24 h dropped from 422 g (3.9 pads) to 38 g (0.69 pads) and the mean ICIQ-SF decreased from 16.25 to 5.3 (p < 0.0001). PROMs (patient-reported outcome measures) showed improvement in 98.9% of cases, and 63.6% gave a “very much better” PGI-I rating. Multivariate analysis identified a lower probability of achieving maximum satisfaction for the following factors: the AdVance XP as first-line therapy (OR 0.35), a lower ICIQ-SF question 1 (OR 0.26), status post-irradiation (OR 0.14), and more severe pain prior to ATOMS implantation (OR 0.51). (4) Conclusions: Implantation of an ATOMS is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an AdVance/AdVance XP sling. High patient satisfaction was demonstrated in a long-term follow-up.
PLA enabled highly specific detection of M3 receptor expression, demonstration of M3/GP differential coupling and intracellular M3 trafficking in human detrusor smooth muscle cells. This new approach minimized background fluorescence and antibody cross-reactions resulting from single antibody application, and enhanced specificity due to the use of two primary antibodies. Use of subcellular markers allowed visualization of subcellular receptor location. PLA/CLSM allows analyses of muscarinic "receptor - G protein - promiscuity" and intracellular trafficking even in bladder paraffin sections and may give new insights into the etiology and pathology of BPS/IC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.