This paper aims at reducing the rating of the power conditioners used in Railways. Co-phase traction employs a Railway Power Conditioner (RPC) for active power balancing, reactive power compensation and Harmonic elimination. The relation between the RPC Rating and the magnitude of the compensating currents and the power angles of the line currents is deduced. Different cases are considered with different combinations of the phase angles, and the best possible case is selected using theoretical analysis and verified by simulation using PSCAD. Comparison is made between the compensated and uncompensated case. The effect of an additional capacitance on the dc-link voltage is also studied. This RPC system is employed in a Traditional traction system used in Indian Railways, with neutral sections and the resulting changes and THD levels of the grid side currents are observed. These results are compared with the Co-phase Traction with RPC and the change in THD levels is noted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.