Miniaturized laboratories on chip platforms play an important role in handling life sciences studies. The platforms may contain static or dynamic biological cells. Examples are a fixed medium of an organ‐on‐a‐chip and individual cells moving in a microfluidic channel, respectively. Due to feasibility of control or investigation and ethical implications of live targets, both static and dynamic cell‐on‐chip platforms promise various applications in biology. To extract necessary information from the experiments, the demand for direct monitoring is rapidly increasing. Among different microscopy methods, optical imaging is a straightforward choice. Considering light interaction with biological agents, imaging signals may be generated as a result of scattering or emission effects from a sample. Thus, optical imaging techniques could be categorized into scattering‐based and emission‐based techniques. In this review, various optical imaging approaches used in monitoring static and dynamic platforms are introduced along with their optical systems, advantages, challenges, and applications. This review may help biologists to find a suitable imaging technique for different cell‐on‐chip studies and might also be useful for the people who are going to develop optical imaging systems in life sciences studies.
Stem cells have an important role in regenerative therapies, developmental biology studies and drug screening. Basic and translational research in stem cell technology needs more detailed imaging techniques. The possibility of cell-based therapeutic strategies has been validated in the stem cell field over recent years, a more detailed characterization of the properties of stem cells is needed for connectomics of large assemblies and structural analyses of these cells. The aim of stem cell imaging is the characterization of differentiation state, cellular function, purity and cell location. Recent progress in stem cell imaging field has included ultrasound-based technique to study living stem cells and florescence microscopy-based technique to investigate stem cell three-dimensional (3D) structures. Here, we summarized the fundamental characteristics of stem cells via 3D imaging methods and also discussed the emerging literatures on 3D imaging in stem cell research and the applications of both classical 2D imaging techniques and 3D methods on stem cells biology.
Nowadays, major attention is being paid to curing different types of cancers and is focused on natural resources, including oceans and marine environments. Jellyfish are marine animals with the ability to utilize their venom in order to both feed and defend. Prior studies have displayed the anticancer capabilities of various jellyfish. Hence, we examined the anticancer features of the venom of Cassiopea andromeda and Catostylus mosaicus in an in vitro situation against the human pulmonary adenocarcinoma (A549) cancer cell line. The MTT assay demonstrated that both mentioned venoms have anti-tumoral ability in a dose-dependent manner. Western blot analysis proved that both venoms can increase some pro-apoptotic factors and reduce some anti-apoptotic molecules that lead to the inducing of apoptosis in A549 cells. GC/MS analysis demonstrated some compounds with biological effects, including anti-inflammatory, antioxidant and anti-cancer activities. Molecular docking and molecular dynamic showed the best position of each biologically active component on the different death receptors, which are involved in the process of apoptosis in A549 cells. Ultimately, this study has proven that both venoms of C. andromeda and C. mosaicus have the capability to suppress A549 cells in an in vitro condition and they might be utilized in order to design and develop brand new anticancer agents in the near future.
The nonlinear absorption responses of graphene, graphene oxide and reduced graphene oxide are investigated using the Z-scan technique and laser beams at 405, 532 and 635 nm in a continuous wave regime. Results show that graphene, graphene oxide and reduced graphene oxide do not show any open Z-scan signals at wavelengths of 532 and 635 nm. At the same time, fresh graphene oxide suspension is found to exhibit a nonlinear absorption process in the case of a laser light at 405 nm. Moreover, it can be observed that the reduction of graphene oxide by 405 nm laser irradiation decreases its nonlinear absorption value significantly. These findings highlight the important role of the reduction process on the nonlinear absorption performance of graphene oxide.
In this work, the nonlinear refractive properties of graphene suspension at different concentration levels are investigated by means of Z-scan technique with continuous wave low power laser beams at 532 nm and 635 nm. Results show that the dispersion of graphene in water exhibits negative nonlinear refractive index in continuous wave regime, which is mainly attributed to thermal nonlinear effect. We find that the absorption coefficient and nonlinear refractive index of the samples increase with increasing the concentration level of the graphene. Moreover, it is obtained that the nonlinear refractive index of the samples at different concentration levels depends on the wavelength of laser beam.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.