Our preliminary data suggest that HA gel fillers with differing production technologies show distinct spread and distribution patterns in the periocular tissues on HRUS examination.
Despite variability in the HA gel distribution and long-term conformational changes on ultrasound examination, HA injection may be an effective and minimally invasive method to improve upper eyelid position for patients with mild eyelid retraction in both the active and inactive stages of TED.
High-resolution ultrasound allows in vivo study of HA injection behavior. HA adopts different morphology within the tissue depending on the density and compliance of the tissues in the plane of injection.
BackgroundPorous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported.Case PresentationThis is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35–69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus.ConclusionsDelayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.
The transorbital extradural approach provides access to the deep orbit and adjacent extradural cranial spaces. Benign orbital tumors that have eroded through the orbital roof, are located in the orbital apex abutting the anterior cavernous sinus and tumors requiring debulking are all processes that can be potentially approached through the transorbital extradural route. Compared to open craniotomy, the incision is smaller, the access more direct and specific risks of open craniotomy are reduced.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.