HighlightsTherefore, although a rare diagnosis, tuberculosis of the tendon sheath should be kept in mind in developing countries. The reason is that the presentation and lab findings of tendon sheath tuberculosis are non-specific, making it hard to differentiate from other causes for this condition. For example a wrist tuberculosis may present with carpal tunnel symptoms. While MR sequences, especially T2, may give hints of tuberculosis, these can be easily misinterpreted as pigmented villonodular synovitis.All these may cause a delay in diagnosis. In order to prevent any delay in diagnostic evaluation, all steps should be taken carefully.Wide debridements to alleviate the symptoms of wrist tuberculosis is not enough a treatment. It is true that wide debridements quickly lessens the symptoms; however, the actual treatment of the condition is antituberculosis treatment directed at the causative organism. Antituberculosis medications are needed to decrease recurrence levels and avoid complications.
Age is the primary risk factor on first year mortality in patients older than 75 years old with hip fractures. Addition to older age, more need to blood transfusions, and arthroplasty are other risk factors for first year mortality. It should be kept in mind that after 75 years old first year mortality may be higher if the patient is treated with arthroplasty.
Objective
Microelectrodes implanted in the central nervous system (CNS) often fail in long term implants due to the immunological tissue response caused by tethering forces of the connecting wires. In addition to the tethering effect, there is a mechanical stress that occurs at the device-tissue interface simply because the microelectrode is a rigid body floating in soft tissue and it cannot reshape itself to comply with changes in the surrounding tissue. In the current study we evaluated the scar tissue formation to tetherless devices with two significantly different geometries in the rat brain and spinal cord in order to investigate the effects of device geometry.
Approach
One of the implant geometries resembled the wireless, floating microstimulators that we are currently developing in our laboratory and the other was a (shank only) Michigan probe for comparison. Both electrodes were implanted into either the cervical spinal cord or the motor cortices, one on each side.
Main Results
The most pronounced astroglial and microglial reactions occurred within 20 μm from the device and decreased sharply at larger distances. Both cell types displayed the morphology of non-activated cells past the 100 μm perimeter. Even though the aspect ratios of the implants were different, the astroglial and microglial responses to both microelectrode types were very mild in the brain, stronger and yet limited in the spinal cord.
Significance
These observations confirm previous reports and further suggest that tethering may be responsible for most of the tissue response in chronic implants and that the electrode size has a smaller contribution with floating electrodes. The electrode size may be playing primarily an amplifying role to the tethering forces in the brain whereas the size itself may induce chronic response in the spinal cord where the movement of surrounding tissues is more significant.
Only a few randomised, controlled studies have compared different non-operative methods of treatment of mid-shaft fractures of the clavicle. In this prospective, randomised controlled study of 60 participants (mean age 31.6 years; 15 to 75) we compared the broad arm sling with the figure of eight bandage for the treatment of mid-shaft clavicle fractures. Our outcome measures were pain, Constant and American Shoulder and Elbow Surgeons scores and radiological union. The mean visual analogue scale (VAS) pain score on the first day after treatment was significantly higher (VAS 1 6.8; 4 to 9) in the figure of eight bandage group than the broad arm sling group (VAS 1 5.6; 3 to 8, p = 0.034). A mean shortening of 9 mm (3 to 17) was measured in the figure of eight bandage group, versus 7.5 mm (0 to 24) in the broad arm sling group (p = 0.30). The application of the figure of eight bandage is more difficult than of the broad arm sling, and patients experience more pain during the first day when treated with this option. We suggest the broad arm sling is preferable because of the reduction of early pain and ease of application.
Background: Knot-tying suture-bridge (SB) rotator cuff repair may compromise the vascularity of the repaired tendon, causing tendon strangulation and medial repair failure. The knotless SB repair technique has been proposed to overcome this possibility and decrease retear rates. Purpose: To compare clinical and structural outcomes and retear patterns between the knot-tying and knotless SB techniques. We hypothesized that the knotless technique would result in lower retear rates owing to the preservation of intratendinous vascularity. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: A total of 104 patients with full-thickness rotator cuff tears were randomly and prospectively allocated to undergo knot-tying (group 1) or knotless (group 2) SB repair. Clinical outcome measures included range of motion, the visual analog scale (VAS) for pain, and the Constant score for function. Repair integrity was evaluated on magnetic resonance imaging scans using the Sugaya classification. Retears were also classified according to their pattern as type 1 (lateral) or type 2 (medial). Results: Overall, 88 patients (group 1: n = 42 [mean ± SD age, 54.3 ± 9.8 years]; group 2: n = 46 [mean ± SD age, 55.8 ± 8.2 years]) were included in the final analysis. The mean ± SD follow-up period was 25.4 ± 8.3 and 23.3 ± 7.2 months for groups 1 and 2, respectively. From preoperatively to postoperatively, the mean VAS pain score improved significantly in both groups (group 1: from 7.4 ± 1.7 to 1.0 ± 1.7; group 2: from 7.1 ± 1.9 to 1.3 ± 2.0; P < .0001 for both), as did the mean ± SD Constant score (group 1: from 51.7 ± 13.4 to 86.0 ± 11.5; group 2: from 49.4 ± 18.4 to 87.2 ± 14.8; P < .0001 for both). There was no significant difference between the groups for the postoperative VAS or Constant score. The retear rate was not significantly different between the groups (19.0% [8/42] in group 1 and 28.3% [13/46] in group 2; P > .05). There was a significant difference in the type 2 failure rate (75.0% [6/8] in group 1 and 23.1% [3/13] in group 2; P = .03). Conclusion: Both techniques showed excellent improvement and comparable clinical outcomes, and there was no significant difference in retear rates. Consistent with previously published data, the type 2 failure rate was significantly higher with the knot-tying technique. Registration: NCT03982108 ( ClinicalTrials.gov identifier).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.